Code Length

(MMII *Fixed for a single length; first read fixes length

(IMT | Fixed for two lengths; first two different lengths read fix lengths

(MMIII | Fixed for 3 lengths; first three different lengths read fix lengths

MMI» Variable length

(MIMI Fixed for 1 length, user fixes length

MINT] © Fixed for 2 lengths, user fixes lengths

(WINIINI! Fixed for 3 lengths, user fixes lengths

© United Barcode Industries Page 4-26

Page 52 read from a scan by OCR; it may hold reading errors

If you selected one of the last three choices for code length, you must enter the length by scanning digits using the bar codes in the full ASCIl chart in Appendix B-1 or in the keypad printed in the Family A menu. Scan End Selection after each length.

Length 1 i Length 2

Length 3

Check Digit -

Compose the desired length Compose the desired length

Compose the desired length

MIMI] © Catcutated and transmitted

(IMAI © Catcutated but not transmitted

NUNN)» *Not Catcutated

End Selection

Page 4-27

© United Barcode Industries

Page 53 read from a scan by OCR; it may hold reading errors

Notes to Family F

Number of Characters

Interleaved 2 of 5 must always encode an even number of characters. An odd length may be selected to allow an Interleaved 2 of 5 label to be scanned into an odd-numbered field. In this case, the MagScan does not transmit either the first or last encoded digit. When the last digit is suppressed, the MagScan will accept a code in which the last character is invalid, e.g. composed of 5 narrow spaces.

Code Length Selection In order to minimize the chance of misreads, Interleaved 2 of 5 codes are often restricted to one or a few fixed lengths. The valid length(s) are selected either by the first read of one or more lengths. In which case the reader will lock onto the first read(s) of different length labels.

For example, if the user authorizes two lengths, the first two labels read of different lengths will establish the two permitted lengths.

Alternatively, the valid length(s) can be selected by bar code menu, in which case the user can specify one, two, or three lengths, to be accepted by the MagScan.

© United Barcode Industries Page 4-28

Page 54 read from a scan by OCR; it may hold reading errors

Check Digit

The Interleaved 2 of 5 check digit can be used as the last encoded character of a label; it is especially recommended when using variable length Interleaved 2 of 5 if the multiple read validation feature discussed above is not activated.

Follow these steps: 1. Add all numbers in the odd place values. 2. Multiply the sum by 3. 3. Add to that product all the numbers in the even place values.

4. The check digit is the complement to this number required to bring the sum to the higher multiple of 10.

For example, determine the check digit: 213461 8cd

(2+3+6+8)x3 = 57 57+1+4+1=63

70 -63 = 7 therefore cd = 7

The label should be 21346187

Page 4-29 © United Barcode Industries

Page 55 read from a scan by OCR; it may hold reading errors

Family G

2 OF 5 STANDARD PARAMETERS

Select Family G

Start/Stop

Code Length

End Selection

MMMM bars LNT *4 bars

TINT 6 or 4 bars iIl|_ *Fixed for a single {AULA length; first read fixes length

Fixed for two lengths; Uy Ml It first two different lengths read fix lengths

IAIAT IN| Fixed for 3 lengths, first three different lengths read fix lengths

(continued on next page)

© United Barcode Industries

Page 4-30

Page 56 read from a scan by OCR; it may hold reading errors

[INIMIIN Variable tength

INIT] Fixed for 1 length, user fixes length

(NINN = Fixed for 2 lengths, user fixes lengths

[NINN] Fixed for 3 lengths, user fixes lengths

If you selected one of the last three choices, you must enter the length by scanning digits using the bar codes in the full ASCII menu Appendix B-1 or in the keypad printed in the Family A menu.

Length 1 LAG A Compose the desired length Length 2

Compose the desired length UN Length 3 HUT Compose the desired length

Check Digit (variable length)

Calculated and MN mitted

INU] | Calculated but not transmitted

(NNN | *Not Calculated

End Selection

Page 4-31 © United Barcode Industries

Page 57 read from a scan by OCR; it may hold reading errors

Family H

CODABAR PARAMETERS

Select Family H

End Selection

Start/Stop

UA AA (MMMM II] © *Nottransmitted MIM» a,b, c,d MMM «=A, B,C, D MUNI» a,b,c,d,n,*,e MW ©=Dc1, Dc2, pcs, pc4

CLSI Library System

NN (MMMM Active (WIN |© *Not active

© United Barcode Industries Page 4-32

Page 58 read from a scan by OCR; it may hold reading errors

Concatenation

A MMII © Al adjacent codes MMI» Al! adjacent codes with same stop of first and start of second MMM ABC IMMUN *Not Active (If active)

Coexistence of Concatenated and Single Labels

(OA MIN] Both single

(unconcatenated) and concatenated labels read and transmitted

(MMIII © Onty concatenated labels read

Page 4-33 © United Barcode Industries

Page 59 read from a scan by OCR; it may hold reading errors

Notes to Family H

CLSI Library System Libraries in the CLSI system used in the United States, require insertions of spaces within the 14 character label.

For example, the label : 399900019214 is transmitted > 3999 0001 9214 .

The start/stop code can be transmitted or not transmitted according to menu selection.

Concatenation

When two or more Codabar labels are placed side by side, and scanned in a single sweep, the reader can transmit the data as a single message. If the reader is programmed to transmit the start/stop characters, it will transmit the first start and last stop characters, and suppress intermediate start and stop characters.

Whether or not two adjacent codes scanned in a single sweep are concatenated can depend on whether the MagScan is programmed to accept certain defined intermediate start/stop combinations.

Concatenation may either be required or may coexist with unconcatenated labels.

ABC

ABC is a form of concatenation used by members of the American Blood Commission. It functions as described in the previous note with the following restrictions on the start/stop characters:

First (leftmost label) Start = A, B, C, or D Stop = D Second (rightmost label) Start =D

Stop = A, B, C, or D

© United Barcode Industries Page 4-34

Page 60 read from a scan by OCR; it may hold reading errors

Family |

UPC/EAN PARAMETERS

Select Family |

Select Formats

Scan the bar code(s) corresponding to each format to be activated. Scan End Selection when all desired formats are specified.

Add-on Digits

End Selection

UPC A UPC E EAN 8

EAN 13

* All Formats

*Not required, but transmitted if present

Required and transmitted

Not required and not transmitted

Page 4-35