Page 31 read from a scan by OCR; it may hold reading errors

Data Bits

Stop Bits

Parity

2400 4800 9600 19200

38400

*Seven

Eight

*One

Two

*Even Odd Mark

Space

© United Barcode Industries

Page 4-6

Page 32 read from a scan by OCR; it may hold reading errors

Applicable to RS-232 as Single or Dual Output:

End of Message Control Code

None

*CR (Hex OD)

LF (Hex OA)

CR, LF (Hex 0D,10) Tab (Hex 09)

ETX (Hex 03)

EOT (Hex 04)

User defined --

Scan single character from full ASCII menu in Appendix B-1

Page 4-7

© United Barcode Industries

Page 33 read from a scan by OCR; it may hold reading errors

Applicable to RS-232 as Input Only:

End of Message Character

IMM IWMI) = “Carriage Return (CR)

Carriage Return, Line Imm) Pariage Ret

User defined -- scan single Hn character from full ASCII menu in Appendix B-1

End of Message Translation

*Same "End of Message" iL l control code sent by MagScan after each read

MMII] «= CRLF (if RS-282 output only)

MMMM Tab

AAA User defined -- scan a single control code from Command menu in Appendix C-1 if wedge or full ASCII menu in Appendix B-1 if RS-232 output

IMNIM! = None

© United Barcode Industries Page 4-8

Page 34 read from a scan by OCR; it may hold reading errors

Post-Block Delay

Post-Block Delay Duration

Mi IN I IN I MI INI

Control Code Retransmission

Active -- Scan a Post-Block delay in following section

*Not Active

20 ms *50 ms 100 ms 500 ms 1 sec 2 sec 5 sec

10 sec

Transmit all

*Transmit none

Page 4-9

© United Barcode Industries

Page 35 read from a scan by OCR; it may hold reading errors

Acknowledge

Negative Acknowledge

XON/XOFF

CTS/RTS

ACK (HEX 06)

Other character -- Scan character from full ASCII menu in Appendix B-1

*Not Used

NAK (HEX 15) Other character -- Scan character from full ASCII menu in Appendix B-1

*Not Used

Active

*Not Active

Active

*Not Active

© United Barcode Industries

Page 4-10

Page 36 read from a scan by OCR; it may hold reading errors

NOTES TO FAMILY B

Interface Definition

The MagScan can make use of its RS-232 interface in either of two modes. 7

RS-232 as Single or Dual Output

The MagScan can be interfaced as a single or dual port RS-232 output device, as described in Section 2.

RS-232 as Input

The MagScan can accept RS-232 input from portable terminals, scales, or other devices and retransmit it via either the wedge or dual RS-232 interface. Use of RS-232 as an input requires the optional part 700501 or 700601 attached to port J3.

Applicable to RS-232 as Input Only End of Message Character

Data from the RS-232 port is received on a message-by-message basis. Data composing each message is buffered until an end of message character (customarily a CR-Hex OD) is received. When it is received the MagScan beeps and sends the record to the host system followed by a control code.

The control code sent by the MagScan to the host after each message from the RS-232 port may be the same as the control code that is transmitted after each message from the bar code scanner as defined in Family A and B bar code menus, as the "End of Message Character."

Page 4-11 | © United Barcode Industries

Page 37 read from a scan by OCR; it may hold reading errors

In some applications, however, it may be desirable to differentiate the control code between each message from the RS-232 port from that sent at the end of each bar code scanned. By activating this feature, the MagScan can, for example, transmit a Tab after each record from the RS-232 port and an Enter after each bar code message.

. | Code B wat

This option allows control characters (Hex 00-20) sent by the RS-232 device to be removed from retransmission by the MagScan to the host. This does not affect the treatment of End of Message or End of BLock characters, but allows such characters as STX, NUL, ETX, etc. to be removed.

This protocol allows the host to poll a MagScan configured in the "RS-232 as Output" mode or a MagScan configured in the "RS-232 as Input" mode to poll a device connected to the RS-232 port.

The protocol is as follows:

Polling device Polled device ENQ |

(If OK) Message ACK (Clears Message) ENQ |

(If not OK) Message NAK |

(If OK) Repeats Message ACK (Clears message)

Note that ENQ/ACK/NAK can be replaced by user defined characters.

© United Barcode Industries Page 4-12

Page 38 read from a scan by OCR; it may hold reading errors

XON/XOFF Protocol

This protocol allows the host to control the flow of data from a MagScan configured in the RS-232 as Output mode or a MagScan configured in the RS-232 as Input mode to control the flow of data for an RS-232 device.

To interrupt reception of data the host or the MagScan transmits the XOFF character (ASCII DC3); to restart the flow, it sends the XON character (ASCII DC1).

The XOFF character is only sent after reception of a complete message. A connected device operating in this mode should wait at least 50 ms between records to verify reception of the XOFF character before starting to send another record.

CTS/RTS

The reader acts as a standard terminal, and manages the RTS/CTS levels when configured to do so in Family B. RTS is brought high before data is transmitted and dropped when transmission of a message is completed. CTS is tested before transmission of each character. Data is only transmitted when CTS is high. If CTS is not used by the host system, the reader maintains the level high. DTR is connected only on _the modem port (toward the host system) and is maintained high.

Page 4-13 © United Barcode Industries

Page 39 read from a scan by OCR; it may hold reading errors

Family C

AUDIO MANAGEMENT AND DATA TRANSMISSION

Select Family C

Audio Management

Speaker Volume

End Selection

(MMIII | Louder (NTH Softer

A total of 7 different levels are avail- able; the default level is 4. By scan- ning "louder" or "softer" successively, the volume is raised or lowered in increments of one level until the maximum or mini- mum level is reached. Two low beeps indicate that the minimum or maximum level has been attained.

© United Barcode Industries

Page 4-14

Page 40 read from a scan by OCR; it may hold reading errors

Preamble

Postamble

“Both ports J2 Wand input

J3 magnetic input

“Both ports J2 wand input

J3 magnetic input

After scanning each port selection for the preamble or postamble, scan one or more charac- ters from the full ASCII chart in Appendix A-1, then scan End Selection.

End Selection

Note: To leave Family C after entering a preamble or postamble, it is necessary to scan the End Selection label a second time.

Page 4-15

© United Barcode Industries