Page 21 read from a scan by OCR; it may hold reading errors

3.2 List of Parameters

Following the configuration menu, the bar code menus are organized into the following families of parameters:

Family

Wedge Interface - Terminal Type Section

RS-232 Interface - Data Communications Parameters Audio Management, and Data Transmission

Bar Code Formats

Code 39 Parameters

Interleaved 2 of 5 Parameters

2 of 5 Standard Parameters rT ou7mmoon9owao >

Codabar Parameters UPC/EAN Parameters

J Parameters for Code 128, MSI, Plessey, Code 11, Code 98, and Code 49

K Magnetic Stripe Parameters

The Families printed in bold are those which it will most often be necessary to modify.

Parameter sections which are not self-explanatory are described in notes following the menu for each family.

© United Barcode Industries Page 3-2

Page 22 read from a scan by OCR; it may hold reading errors

3.3

Preparing the MagScan for Configuration

To configure the MagScan follow these steps; additional notes on the configuration sections are provided following the configuration menu.

a)

b)

d)

From the configuration chart on page 3-6, read the command "Configuration"

Select one of the families of parameters by turning to the appropriate section of the manual ad reading the Enter Family bar code of the family you wish to change. In most cases it will be necessary to enter and make changes in Family A or B, and K, at a minimum.

Within the family, read the bar code of the parameter to be changed, then the option to be selected. Repeat this step for other parameters within the same family.

When all the parameters within a family which you wish to change are modified as described, read the "End Section" label, at the top right hand corner of each setup menu.

Repeat steps b, c, and d for each family in which you wish to change one or more parameters.

When you have finished changing all families of parameters as desired, read the "End Configuration"., Page 3-3 © United Barcode Industries

Page 23 read from a scan by OCR; it may hold reading errors

3.4 Default Values

The MagScan is shipped with all parameters set to their default values, which are marked with asterisks(*) in the bar code setup menus in this guide. On request the MagScan can be shipped in a custom configuration.

3.5 End Section

End Section bar code labels appear at the top of each bar code menu. They are read to perform either of the following two types of operations.

1. When the configuration within a Family of parameters is complete, scanning End Section enables the user to enter another Family or to return to the menu of Configuration Commands.

2. To perform certain operations (e.g. establishment of the number of permitted characters in interleaved 2 of 5, or definition of preamble/postamble) the user is asked to scan one or more bar codes from the full ASCII and Command menus in Appendixes B-1 and C-1. When the desired character(s) is (are) entered, the user scans End Section to indicate that the definition is complete. In this case, scanning End Section does not result in exiting the Family, and another parameter in the same Family can be accessed without re-scanning the Select Family bar code. To exit the family immediately after composing a character string from the full ASCII menu, it is necessary to read the End Section bar code a second time.

Note that it is not necessary to scan End Selection following the entry of user defied characters for commands where only one length is permitted. For example all configuration numbers in Family A consist of three digits, and the MagScan accepts the configuration number selection following the entry of the third digit.

© United Barcode Industries Page 3-4

Page 24 read from a scan by OCR; it may hold reading errors

3.6 Operator Indicators

Invalid configuration commands are signaled by two beeps in a low pitch. Theses result from reading a configuration bar code out of its proper sequence. An example would be if a Select Family bar code is read before and End Selection bar code is read to exit the previously used family.

Page 3-5 © United Barcode Industries

Page 25 read from a scan by OCR; it may hold reading errors

1. | Configuration Commands

Step One

Enter Configuration

Step Two

Modify parameters as required using the menus organized into Families in this manual.

Step Three

End Configuration ll. Returning to Default Parameters

Return to Default Parameters

© United Barcode Industries Page 3-6

Page 26 read from a scan by OCR; it may hold reading errors

Section 4

Families of Parameters

Page 4-1 © United Barcode Industries

Page 27 read from a scan by OCR; it may hold reading errors

FAMILY A

WEDGE INTERFACE SELECTION OF TERMINAL TYPE

Select Family A IAN End Selection IMAM Compose Terminal Identification Number IN IN INNA TAM 1 2 3 A IN JNM 4 5 | 6 IN INU IN 7 8 9 IN 0

Compose the identification number of the terminal to which the MagScan is to be attached, as defined in Appendix A.

Default: 163 -- IBM AT and compatibles.

© United Barcode Industries Page 4-2

Page 28 read from a scan by OCR; it may hold reading errors

End of Message Control Code

(ANA A INN None MNT» *Enter (ANNUM Return HHH | il Down Arrow MMI» Field Advance (MMM Fieta Exit UM tab

(MINI )©« User Defined -- Scan control code from Appendix C-1

Upper/Lower Case

(IMMIMIM» *Lower Case

(MINI ©~ Upper Case (host terminal keyboard has caps lock activated)

End Selec

Page 4-3 © United Barcode Industries

Page 29 read from a scan by OCR; it may hold reading errors

Notes to Family A, ee

Compose Terminal Type

The MagScan can be set to emulate a large number of terminals, as listed in Appendix A. To configure the MagScan for a specific terminal, the terminal identification number must be composed for Family A, and the appropriate set of cables must be installed, as described in Section 2.

End of Message Control Code

The MagScan is connected as a wedge, it can send after each message acontrol code which emulates a command key on the keyboard thereby allowing automatic entry of data.

Upper/Lower Case

In order to transmit alphabetical characters in the correct case, the MagScan must be set for the shift position of the keyboard of the terminal to which it is interfaced. When the keyboard is in the normal, unshifted position, lower case is used. When the caps lock is activated on the terminal’s keyboard, upper case should be selected.

© United Barcode Industries Page 4-4

Page 30 read from a scan by OCR; it may hold reading errors

FAMILY B

RS-232 INTERFACE -- DEFINITION AND PARAMETERS

Select Family B

NL End Selection terface Definition A RS-232 as single

Hn WHIM) Saeco

IMM!» RS-282 as input

Applicable to all Interface Definitions:

Baud Rate nu wy lim» °°” re

(continued on next page)

Page 4-5 © United Barcode Industries