Page 11 read from a scan by OCR; it may hold reading errors

Section 2 sss.

Installing the MagScan

2.1 Installing the MagScan as a Wedge

Installing the MagScan as a wedge requires specifying the correct, part number (P/N 155000), selecting the proper Cable Management

Module (CMM), (P/N 3250XX), and the proper Wedge Cable (P/N

601XXX). The Wedge Cable and CMM required are shown in

Appendix A of this manual or in UBI’s Commercial Price List. The

Wedge Cables are designated as 601 XXX where XXX is an identi-. fication number for a cable type compatible with one or more terminals or PC’s. |

The MagScan cable terminates in an 8 pin connector and is plugged into the port labeled "Reader" on the CMM. The 601 XXX cables are also connected to the CMM. To install the 601XXX cables, the modular 6 pin side labeled "J2 to Keyboard" is plugged into the CMM port labeled "To Keyboard". The keyboard cable of the terminal is disconnected and plugged into the mating 601 XXX connector labeled "J2 to Keyboard". The other 601XXX cable 6 pin modular side labeled "J1 to Display” is plugged into the CMM port labeled "To Display". The other side of the 601 XXX cable labeled "J1 to Display" is plugged into the terminal’s keyboard port to which its keyboard cable was previously connected.

The proper connection of the MagScan is shown in Figure 2-1, on page 2-2.

"© United Barcode Industries Page 2-1

Page 12 read from a scan by OCR; it may hold reading errors

FIGURE 2-1

MAGSCAN CONNECTED AS A WEDGE

Bar Code Scanner (Optional)

Wedge: Adapter Cable

[BEEZ ve

Cable Port } Host Terminal

Host Terminal b/ S {7 o 4) Keyboard Cable

Page 2-2 © United Barcode Industries

Page 13 read from a scan by OCR; it may hold reading errors

2.2 Installing the MagScan as Single RS-232 Device

Installing the MagScan as a single RS-232 device requires specifying the correct part number (P/N 155600), plus the proper CMM, (P/N 704300, 704310, 704320, 704330, 704340, 7043XX, depending on the pin assignments of the connector). Please see figure 2-3 for pin assignments.

In most RS-232 applications it is necessary to connect a power supply (P/N 700901) to the jack incorporated on the CMM. To install the MagScan RS-232, the power supply is plugged into the CMM port labeled "Power Supply", the 8 pin connector from the MagScan is plugged into the CMM port labeled "Reader" and the RS-232 DB connector is plugged into the serial port on the PC terminal.

In O.E.M. applications, use of a power supply may be avoided if +5 VDC at minimum 115 mA is supplied on power pin of the CMM.

© United Barcode Industries Page 2-3

Page 14 read from a scan by OCR; it may hold reading errors

FIGURE 2-2

MAGSCAN CONNECTED AS A SINGLE RS-232 DEVICE

RS-232 Output Cable

Power Supply

Bar Code Scanner (Optional)

Page 2-4 © United Barcode Industries

Page 15 read from a scan by OCR; it may hold reading errors

NON OAARAN, On

FIGURE 2-3 ee

SINGLE RS-232 PIN ASSIGNMENTS Single Output Cable Management Module (CMM)

PIN

Standard DB-25S (Female) " DT E"

(P/N 7043-1) Frame Ground Transmit Data Receive Data Request To Send Clear to Send NC

Signal Ground NC

+5V NC

PIN

Standard

25 Pin PC Serial (Female) "DCE"

P/N 7043-

Frame Ground Receive Data Transmit Data Clear to Send Request to Send NC

Signal Ground NC

+5V

NC

Note: Pins 6,8 and 20 are shorted

ASSIGNMENT

Standard

DB-25S (Male) "DTE" (P/N 7043-2) Frame Ground Transmit Data Receive Data Request to Send Clear to Send NC

Signal Ground NC

+5V NC

ASSIGNMENT

Standard 9 Pin AT Serial (Male) "DCE"

P/N 7043-4

NC

Transmit Data Receive Data NC

Signal Ground NC

Clear to Send NC

NA

NA

© United Barcode Industries

Page 2-5

Page 16 read from a scan by OCR; it may hold reading errors

2.3 Installing the MagScan as a Dual Output RS-232 Device

Installing the MagScan as a dual output RS-232 device requires the addition of one of UBI’s Dual Output options and a power supply (P/N 700901). The standard CMM (P/N 704300) is mated with either the Standard Dual Output Option (P/N 700302) or the Reverse Gender Dual Output Option (P/N 701302).

The Dual RS-232 option can be set via the placement of jumpers on its circuit board, to transmit data in full duplex to either host only or terminal only, or in half duplex to both host and terminal simulta-neously. Pin assignments and diagrams for dual RS-232 are provided in figure 2-4, 2-5 and 2-6.

The Dual RS-232 options are designed to conform to standard hardware connections between the data communications line and the terminal, so as not to require any modification to the adapter or additional cables.

Once the adapter is in place, it will not affect communications between the display terminal and the host.

Page 2-6 © United Barcode Industries

Page 17 read from a scan by OCR; it may hold reading errors

FIGURE 2-4

MAGSCAN CONNECTED AS A DUAL RS-232 DEVICE Dual -E===s RS-232 _ Option ? 3) Host L Computer Display

Terminal

RS-232 Output | Cable

Power

Supply Bar Code Scanner 3 (Optional) aN R > 4

© United Barcode Industries Page 2-7

Page 18 read from a scan by OCR; it may hold reading errors

FIGURE 2-5 a nl STANDARD DUAL RS-232 OPTION

(P/N 700302)

WM J2

Ju . 25 Pin mpes 25 Pin Female Male (Host) Ly 1, (Terminal) TO>| 2 Bi \s ep 2 I>RD RD<j 3 x1 bod 3 |<TD Bale ATS>] 4 e A do 4 |>RTs x2 cTs<| 5 ef 5 |<cTs ef GROUND 7 e 7 |GROUND e +5v| 9 ry) Q x4 ry 9 |45v 3 | To MagScan Note: Pins 1,6, 8, 10-12, 14-16, 18, 20, and 25 are connected straight through. Jumper Settings Full duplexto Full duplexto Half duplex host (J1) only terminal (J2) only toboth host (J1) (defaultsetting) and terminal (J2) e fe] x1 e x1 x1 hd, © x x2 ex e e fe | x3 x%* *8 A 9 @ LJ

Page 2-8 © United Barcode Industries

Page 19 read from a scan by OCR; it may hold reading errors

FIGURE 2-6

REVERSE GENDER DUAL RS-232 OPTION (P/N 701302)

? J2 Ju . 25 Pin Netld nee Female Nee , - (Terminal) {VU x Os ee Rp» [2 D> Se a 2|>TD 3 a) q De p [] qq 3 |<RD O q q ats> | 4 5 dq 4d 4 |>RTS cts<|5 2 i 5 |<CTS GROUND | 7 7 |GROUND sv | 9 ln X4 ry 9 |+5v | J3 | To MagScan Note: Pins 1,6, 8, 11, 13-15, 17, 20, 22 and 24 are connected straight through. Jumper Settings Fullduplexto Full duplexto Half duplex host (J1) only terminal (J2) only toboth host (J1) (defauttsetting) andterminal (J2)

ee ~

[ee]

[ee}x

[ee] x [ee] x

© United Barcode Industries

Page 2-9

Page 20 read from a scan by OCR; it may hold reading errors

Section 3 Configuring the MagScan

3.1 Introduction

To configure the MagScan using the bar code menus in this manual, a wand must be connected to the bar code input port.

The MagScan must be powered on to perform the configuration. This is accomplished when it is connected to the host terminal as a wedge, and the host is powered on, or when a power supply is attached in the RS-232 configuration.

All key parameters of the MagScan are programmed via bar code menus organized into families. The user must configure the MagScan for the terminal or system to which it is to be attached (unless the MagScan is configured as a wedge and the host terminal is an AT compatible -- the default setting), but need only enter other families in which the default values are to be modified.

Page 3-1 © United Barcode Industries