Page 51

Introduction to the TSC1 Datalogger

3.7

3

Data Capacity The TSC1 datalogger is supplied with 2 MB of internal memory for data storage, which in most cases provides enough capacity for your data logging requirements. Table 3.2 provides estimates of the data logging capacities of the TSC1 datalogger under various data collection scenarios. Although the TSC1 can hold a large volume of data, Trimble recommends that you transfer data files to your office PC daily. Table 3.2

Data capacities for rover and base files

File type

Logging interval

Carrier logging

Logging time

Rover

1 second

On

2 - 2.5 hours

1 second

Off

6 hours

5 seconds

On

10 hours

5 seconds

Off

30 hours

Base

5 seconds

14 hours

15 seconds

35 hours

Note – For the highest accuracy of differentially corrected positions, Trimble recommends that the rover position interval be set to a multiple of the base station interval.

B

Tip – If you must log data for longer periods, you can increase the GPS logging intervals.

If you require more memory for data storage than is available in the TSC1 datalogger’s internal memory, use a PC card.

TSC1 Asset Surveyor Operation Manual

29

Page 52

3

Introduction to the TSC1 Datalogger

3.8

Physical Specifications Table 3.3 lists the specifications of the TSC1 datalogger. Table 3.3

TSC1 physical specifications

Property

Specification

Size

266 mm x 116 mm x 42 mm (10.5 in x 4.6 in x 1.65 in)

3.9

Weight

844 gms (1.86 lbs)

Power

<1 W

Operating temperature from –20°C to +65°C (–4°F to 150°F)

Storage temperature from –30°C to +80°C (–22°F to +176°F)

Humidity

95 % non-condensing

Casing

UV-resistant plastic, resistant to wind-driven rain and dust

Memory

2 MB internal flash memory

Communications

2 x RS232 serial ports

Display

240 x 200 Graphics LCD display with backlight

Power Sources The TSC1 datalogger is supplied with a Lithium-ion battery (part number 29518). This is a 7.4 V 1.2 AH rechargeable battery.

C

Warning – Only use Trimble-approved batteries in the TSC1 internal battery compartment. Otherwise, the unit may be damaged.

The receiver, or another external power source, provides the power for the TSC1 datalogger, except when the TSC1 is running off its internal battery.

30

TSC1 Asset Surveyor Operation Manual

Page 53

Introduction to the TSC1 Datalogger 3.9.1

3

Battery Status The status line displays the status of the TSC1 battery and of any external power source (usually a receiver), depending on the source currently being used. For a list of items that appear in the status line, refer to the TSC1 Asset Surveyor Software User Guide. You can also view the power status by selecting Configuration / Hardware (TSC1). The Internal battery and External battery fields show how much power remains, and indicate whether the source being used by the TSC1 datalogger is internal or external. The values for the Internal battery and External battery fields are expressed as percentages, and are calculated by comparing the reported voltage against the possible range for the power source in question. For example, the percentage displayed for the External battery field is computed by comparing the reported voltage against the possible voltage range (vmin to vmax) for camcorder batteries, as follows: External battery % = (voltage – vmin) / (vmax – vmin) × 100 The percentage displayed for the Internal battery field is computed by comparing the reported voltage against the possible range for the lithium-ion battery, as follows: Internal battery % = (voltage – vmin) / (vmax – vmin) × 100 Note – The percentage reported for new batteries may be less than 100%. The calculation of the battery percentage assumes a range typical of a new battery, so used batteries may report percentages well under 100%. This is because repeated recharging of batteries normally results in a reduced potential maximum voltage.

TSC1 Asset Surveyor Operation Manual

31

Page 54

3 3.9.2

Introduction to the TSC1 Datalogger

Low Battery Warnings When the Asset Surveyor software detects that the internal battery voltage is low, the following message appears: The internal battery is low

This usually occurs when the voltage level has dropped to about 10%. You can continue to use the TSC1 datalogger for a short period, but replace or recharge the battery as soon as possible. When the Asset Surveyor software detects that the main battery voltage is so low that it cannot function, the following message appears: Internal battery is dead

The TSC1 datalogger shuts down. You must then replace or recharge the battery. Note – When the internal battery can no longer function, no data is lost, as data in the TSC1 datalogger is stored in the flash memory.

3.9.3

Recharging the TSC1 Battery You can recharge the datalogger’s lithium-ion battery in one of two ways:

32

• using a Trimble Support Module (TSM™) power supply

• using a low voltage power supply (such as a camcorder battery)

TSC1 Asset Surveyor Operation Manual

Page 55

Introduction to the TSC1 Datalogger

3

Using a Trimble Support Module (TSM) To charge the TSC1 battery using a TSM, connect the TSC1 datalogger to a TSM as shown in Figure 3.4.

1

4

3 2

1 2 3 4

P/N 38246-00 P/N 14284 P/N 32287-00 TSC1 datalogger

Figure 3.4

Trimble Support Module (TSM) TSM extension cable TSC1 data/power cable

Cabling for charging a TSC1 battery using a TSM

1.

Plug the TSM into the wall current (mains),

2.

Connect the TSM to the extension cable (P/N 14284). Attach this to the TSC1 data/power cable (P/N 32287-00). This cable connects to either the top or bottom port of the TSC1 datalogger.

The battery recharges fully in approximately three hours.

TSC1 Asset Surveyor Operation Manual

33

Page 56

3

Introduction to the TSC1 Datalogger

Using a low voltage power supply You can recharge the TSC1 battery using a power source of less than 15 V.

3.9.4

1.

Connect the TSC1 datalogger to a GPS receiver with an external power source, or directly to a camcorder battery.

2.

Open Configuration / Hardware (TSC1) and set the Low voltage charging field to ‘On’.

3.

The TSC1 battery will charge off the external power source until it reaches maximum capacity.

Alternative Power Sources If it can, the TSC1 datalogger draws power from the GPS receiver’s power source. This is used in preference to the lithium-ion battery.

3.10

Ports The TSC1 datalogger has two data/power ports. One port is at the bottom of the unit, the other is at the top on the back. Both ports function in the same way. Figure 3.2 on page 22 shows where these ports are located on the TSC1 datalogger. The Asset Surveyor software automatically detects which port is connected to an external device. Whichever port is connected first is the one that is used.

34

TSC1 Asset Surveyor Operation Manual

Page 57

Introduction to the TSC1 Datalogger

3.11

3

Servicing The TSC1 datalogger does not need to be serviced. To clean the TSC1 datalogger, use a soft cloth moistened with water and a mild soap. If your TSC1 datalogger develops a fault, transfer any data to your PC and reset the TSC1 with a cold boot as described on page 28. If you cannot transfer the data, do not perform a cold boot. Contact your local dealer for advice. Contact your dealer for repairs, replacement parts, service information, and technical assistance. If you need more help, see the section on Technical Assistance in the beginning of this manual. You can also contact Trimble at the address listed inside the front cover. Note – Other Trimble software (such as the Trimble Survey Controller™ software) can also be installed on a TSC1 datalogger. Please see your Trimble dealer for details.

TSC1 Asset Surveyor Operation Manual

35

Page 58

3

Introduction to the TSC1 Datalogger

36

TSC1 Asset Surveyor Operation Manual

Page 59

CHAPTER

4 4

Before Leaving the Office In this chapter: ■

Introduction

■

Planning

■

Projects

■

Data dictionaries

■

Waypoints

■

Coordinate systems

■

Data files

■

Data transfer

■

Configuring the system

■

GPS hardware check list

■

Getting base station data

Page 60

4

Before Leaving the Office

4.1

Introduction This chapter explains what to do before you take the Asset Surveyor software out into the field.

4.2

Planning Obtaining the desired accuracy requires good planning. The Quick Plan software lets you plan the best times to collect GPS data. The following information is useful when planning for data collection: •

The number of visible satellites

•

Where the satellites travel

•

The PDOP (Position Dilution of Precision)

The more satellites that are visible, the better. PDOP provides an indication of the expected accuracy of your GPS positions based on the relative positions of the satellites. Lower PDOP values provide more accurate data.

38

TSC1 Asset Surveyor Operation Manual