The text of a manual · part 5 of 47
TSC1 Asset Surveyor Operation Manual, pages 41 to 50
Pages 41 to 50 of 470
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSC1
Page 41
CHAPTER
3 3
Introduction to the TSC1 Datalogger In this chapter: ■
Introduction
■
What is the TSC1?
■
Turning the TSC1 datalogger on and off
■
Screen
■
Memory
■
Rebooting
■
Data capacity
■
Operating temperature and humidity ranges
■
Power sources
■
Ports
■
Servicing
Page 42
3
Introduction to the TSC1 Datalogger
3.1
Introduction This chapter contains hardware specifications and gives instructions on operating, storing, and maintaining the TSC1 datalogger.
3.2
What is the TSC1? The Trimble System Controller (TSC1) is a powerful handheld field computer with a full alpha-numeric keyboard, a 200 x 240 pixel liquid crystal display (LCD) and two serial communications ports. The TSC1 datalogger contains a proprietary processor based on the Motorola CPU32 core, capable of executing up to 20 MHz. It also has a built-in real-time clock, which is maintained when the unit is powered down. The TSC1 datalogger has 2 MB of DRAM (working memory) and 2 MB of flash disk memory for data storage, capable of storing about 35,000 GPS positions. A portion of the flash disk memory is allocated to program space, and this is where the Asset Surveyor program files, language files, and help files reside. This chapter describes the features and operation of the TSC1 datalogger using the Asset Surveyor software. For a detailed description of how to use the TSC1 datalogger with the Asset Surveyor software, refer to the TSC1 Asset Surveyor Software User Guide. Figure 3.1 and Figure 3.2 show different views of the TSC1 datalogger. Use them to become familiar with the terms used in this manual.
20
TSC1 Asset Surveyor Operation Manual
Page 43
Introduction to the TSC1 Datalogger
3
PC card
Function keys
Multi-directional arrow key
Backspace key
Second function key
Space key
Caps lock key
On/Off key
Help key
To receiver Power/data cable Figure 3.1
Front view of the TSC1 datalogger
TSC1 Asset Surveyor Operation Manual
21
Page 44
3
Introduction to the TSC1 Datalogger
Top port PC card cover release button
Battery cover
Battery cover screw
Bottom port Power/data cable Figure 3.2
22
Back view of the TSC1 datalogger
TSC1 Asset Surveyor Operation Manual
Page 45
Introduction to the TSC1 Datalogger
3.3
3
Turning the TSC1 Datalogger On and Off
|
To turn on the TSC1 datalogger, make sure that power is supplied (see Power Sources, page 30). Then press the green on/off key marked .
|
To turn off the TSC1 datalogger, hold down For the location of the see Figure 3.1.
3.3.1
| for one second.
key and other keys on the TSC1 keypad,
Hard Keys
1 a\() =
Hard keys are the physical keys on the TSC1 keypad, such as , , , , , and . Use these keys to enter data and to access different screens.
3.3.2
Alternate Keys Alternate keys give some hard keys a second function. Some of the second functions are displayed on the hard keys in small yellow lettering. To use a second function, press the hard key and then press the alternate hard key.
[
Table 3.1 shows some of the functions that you can access using alternate keys. Table 3.1
[) [_ [* [( [N Keys
Useful second functions Function Page down Page up Home End Previous screen
TSC1 Asset Surveyor Operation Manual
23
Page 46
3
Introduction to the TSC1 Datalogger Table 3.1
Useful second functions (Continued)
[e [f Keys
3.3.3
Function Contrast up Contrast down
Softkeys
!@#$%
Softkeys are displayed on the bottom line of the TSC1 screen. A softkey corresponds to the adjacent hard key: , , , , . Press the hard key to activate the softkey on the screen. For example, to activate the softkey, press . See Figure 3.3.
p
!
! @ # $ % Figure 3.3
How function keys correspond to softkeys s
Softkeys relate to particular forms or fields and only appear when these forms or fields are accessed. For example, the softkey only appears when a line feature is opened for data collection, as this functionality applies to line features only.
24
TSC1 Asset Surveyor Operation Manual
Page 47
Introduction to the TSC1 Datalogger 3.3.4
Menu Key
3
M
N
To return to the Main menu at any time, press the hard key. Use this key in conjunction with the key to move around the Asset Surveyor screens quickly.
3.3.5
Next Key To simplify the task of moving around menus, the quick access to open screens (windows).
3.3.6
Help Key
?
N hard key offers
Press the hard key at any time to obtain further information about a topic. When you press it, the Help menu appears. To exit the Help module, press from the Help menu.
3.4
=
Screen The TSC1 datalogger has an LCD screen. This screen responds to heat, and prolonged exposure to full sunlight can cause it to darken. If this happens, turn the screen away from direct sunlight until it returns to normal.
C 3.4.1
Warning – Repeated exposure to direct sunlight can cause the screen to degrade.
Contrast To increase the screen contrast, press To decrease the screen contrast, press
[e [f
. .
TSC1 Asset Surveyor Operation Manual
25
Page 48
3
Introduction to the TSC1 Datalogger
3.4.2
Backlight To switch the screen backlight between on and off, press
3.4.3
[l
.
Disconnecting from the Receiver To disconnect the TSC1 datalogger from the receiver, close any file that is open and turn off the TSC1 datalogger. You can then disconnect the TSC1. If you accidentally disconnect the TSC1 while collecting data, simply reconnect and, when the receiver has acquired enough satellites to compute GPS positions again, continue collecting data.
3.5
Memory The TSC1 datalogger has 2 MB of internal memory for data storage. While some dataloggers use battery-backed static memory, the TSC1 datalogger uses flash memory. With flash memory, you do not need a backup battery to preserve data when the system is turned off. Since backup battery failure is a common cause of data loss, this means that the TSC1 datalogger provides exceptionally secure data storage. You can supplement the internal flash memory by using PC cards, which are inserted in the side of the datalogger. PC cards are available in various sizes. Trimble supplies 16 MB PC cards.
26
TSC1 Asset Surveyor Operation Manual
Page 49
Introduction to the TSC1 Datalogger 3.5.1
3
Choosing a PC Card Only Type I or Type II ATA format PC cards are supported by the TSC1 datalogger at present. Trimble supplies a 16 MB card (part number 33050-16). In addition to the cards supplied by Trimble, PC cards from the following manufacturers have been tested successfully in the TSC1 datalogger:
3.6
•
Epson
•
IBM
•
SanDisk
•
Viking
Rebooting If the Asset Surveyor software fails to respond to any keystrokes, you may have to reboot the system. To do this, turn off the TSC1 datalogger and turn it back on again. If this does not work, hold down for five seconds, then release it. Press it again to turn on the TSC1 datalogger. If this does not work, perform a warm boot.
|
Note – If the software fails to respond to keystrokes, check that the TSC1 datalogger is receiving power.
3.6.1
Warm Boot A warm boot shuts down the hardware and restarts the Asset Surveyor software. It also resets the software to the factory default settings. If you ever have to perform a warm boot, transmit any data from the TSC1 datalogger to your PC as soon as possible, to safeguard against further problems, and to avoid any possibility of data loss. Note – You do not lose data when you perform a warm boot, but you do lose all your configuration settings.
TSC1 Asset Surveyor Operation Manual
27
Page 50
3
Introduction to the TSC1 Datalogger
To perform a warm boot: 1.
Make sure that the TSC1 datalogger is off, using a five-second power down if necessary.
2.
key, press and release the While holding down the This powers on the TSC1 datalogger.
B
| key.
The TSC1 datalogger should restart after a few seconds and the Asset Surveyor software should run. If the warm boot fails, perform a cold boot.
3.6.2
Cold Boot A cold boot erases the internal memory and restarts the Asset Surveyor software. It does not affect the PC card.
C
Warning – All data in the TSC1 datalogger's memory, including any data dictionaries and extra coordinate system files you have downloaded onto the TSC1 datalogger, is lost after a cold boot. Only perform a cold boot if a warm boot has previously failed, or if you know that the TSC1 has no data in its memory.
To perform a cold boot: 1.
Make sure that the TSC1 datalogger is off, using a five-second power down if necessary.
2.
Hold down
3.
While holding them down, press and release the turns on the TSC1 datalogger).
4.
When the following message appears on the screen:
[ % and
[ % together.
| key (which
Force Reformat Internal Media release and software starts.
28
. After a few minutes, the Asset Surveyor
TSC1 Asset Surveyor Operation Manual