8.
Press
=
RTK Field Procedures
3 again to return to the main menu.
Note – To upload grid coordinates using the Trimble Geomatics Office, Trimble Survey Office or TRIMMAP™ software, refer to the Trimble Survey Controller Reference Manual.
3.6.2
Setting Auto Calibrate to Yes To set the Auto calibrate field to Yes: 1.
End the current survey and return to the main menu. For more information, see Ending the Survey, page 54.
2.
From the main menu, Select Survey. The Select Survey Style menu appears.
3.
Highlight your new RTK Survey Style and press the softkey. For more information, see Step 2 on page 35.
E
The menu that appears has the same name as the RTK Survey Style that you added and contains all the options for an RTK survey.
\
. The Site calibration
4.
Highlight Site calibration and press screen appears.
5.
Press to move to the Auto calibrate field. Press the setting to Yes, then press .
6.
again to accept the screen. This takes you back to the Press menu of Survey Styles.
7.
Press the Style menu.
8.
Press
) \
O
\ softkey or
\ =
* to toggle to return to the Select Survey to return to the Survey menu.
Trimble Survey Controller Field Guide
45
Page 60
3 3.6.3
RTK Field Procedures
Using GPS to Measure Calibration Points You have keyed in grid coordinates for the control points. For more information see Keying In the Grid Coordinates, page 44. Now use GPS to measure these control points as calibration points. The Trimble Survey Controller software automatically matches the keyed-in grid points to the measured WGS-84 values, calculates and stores the calibration.
f
When you have calibrated one point or defined a projection and datum transformation, the softkey appears. Use it to navigate to the next control point. As you measure another calibration point, the new calibration is calculated and stored. To measure calibration points: 1.
From the main menu, Select Survey.
2.
From the Select Survey Style menu, select your new RTK Survey Style. For more information, see page 35.
3.
Select Measure points. Press the key to move to the Method field. Change the setting to Calibration point.
4.
Access the Grid point name field by pressing . Then press the softkey. A list of keyed in grid coordinates appears.
5.
B
( \
. The point Highlight the point to be measured and press name is inserted in the Grid point name field and the GPS point name field is automatically filled.
k
\
Tip – If you have not yet keyed in the grid coordinates for this point, press softkey in the Grid point name field. The Key in/Point screen the appears. Enter the coordinates and press .
6.
46 l
)
Enter values for the Code and Antenna height fields. Press to accept the screen.
Trimble Survey Controller Field Guide
\
Page 61
7.
m
RTK Field Procedures
\
3
When the antenna is centered and vertical over the control point, press the softkey or . The TSC1 data collector starts to record data and the static icon ( ) appears.
s
Keep the antenna vertical and stationary while data is recorded. 8.
s softkey When the preset required time has elapsed, the appears. Inspect the precisions. If they are satisfactory, press to store the point.
The Trimble Survey Controller software automatically does the calculations and stores the results. While this is happening, the following messages appear: Please wait. Storing point Calculating calibration Storing calibration
Note – If a calibration exceeds the tolerances set in the Site calibration option for the Survey Style, the residuals are displayed. Select which points to use. For more information, refer to the section on Auto calibrate in the Calibration chapter of the Trimble Survey Controller Reference Manual. 9.
f
Enter the next calibration point name in the Grid point name softkey. The navigation screen field and press the appears. The azimuth and distance to the next point appear on the right of the screen. To navigate using the arrow in the graphical display screen, move forwards with the TSC1 data collector held in front of you. The arrow points in the direction of the next calibration point. Walk towards the point. When you are about 3 meters or 10 feet from the point, the display changes. Two concentric circles (resembling a bull’s-eye) show the position of the point, and a cross shows your position. Walk towards the point until the cross is over the circles. Find the physical control point, and place the range pole over it. Press to return to Step 7.
=
10. Repeat these steps until all calibration points are measured.
Trimble Survey Controller Field Guide
47
Page 62
3
RTK Field Procedures
3.7
Stakeout This section shows how to stake out a point. To do this, set up the base receiver (see page 29), then use the rover receiver to locate and stake out points. Always use a real-time survey for stakeout operations. Trimble recommends that you carry out a complete calibration before staking out any points. Note – Before staking out grid coordinates, define a projection and datum transformation.
3.7.1
General Procedure To stake out a point: 1.
Define the point and store it in the Trimble Survey Controller software database. To define the point, do one of the following:
48
– key in data
– upload a job from the Trimble Geomatics Office or Trimble Survey Office software
– calculate coordinates using one of the Cogo functions
2.
Initialize the survey.
3.
Navigate to a point.
4.
Stake/mark the point.
5.
Measure the as-staked point (this is optional).
6.
Repeat Step 3 through Step 5 until all points are staked out.
7.
End the survey.
Trimble Survey Controller Field Guide
Page 63
RTK Field Procedures
C
3
Warning – Do not stake out points and then change the coordinate system or perform a calibration. If you do, any points staked out after the changes will not be in the same terms as the points already staked out.
The rest of this section shows how to key in a point using the Key in option, and then stake it out. For information on other methods, refer to the Trimble Survey Controller Reference Manual and the online Help.
3.7.2
Keying In a Point To key in a point:
(
1.
From the main menu, select Key in / Points. The Key in/Point screen appears. Move the highlight to the Point name field and press .
2.
Type the point name and enter a code if required.
3.
Set the Method field to Keyed in coordinates.
o
You can key in grid, local, or WGS-84 coordinates. To change softkey and change the the coordinate fields, press the coordinate view.
\ =
\
.
4.
Key in the coordinates and press
5.
Press
6.
Repeat Step 2 through Step 5 for each point, then press return to the Key in menu.
7.
Press again to store the point.
= to again to return to the main menu.
Trimble Survey Controller Field Guide
49
Page 64
3 3.7.3
RTK Field Procedures
Staking Out a Point To stake out a point: 1.
From the main menu, select Survey. From the Select Survey Style menu, select your new RTK Survey Style. For more information, see Step 2 on page 35. Note – If a survey is already running, the Select Survey Style menu does not appear. If the current survey is not using your new RTK Survey Style, end it (see page 54) and return to Step 1.
2.
Select Stakeout / Points. A screen similar to Figure 3.6 appears.
Figure 3.6
Stakeout/Points screen
If this is the first time you have used the Stakeout function in this job, this list is empty.
50
Trimble Survey Controller Field Guide
Page 65
RTK Field Procedures
3.
3
A
Transfer points from the Trimble Survey Controller software database to the Stakeout/Points list. To do this: a.
softkey. The Select point screen appears, Press the see Figure 3.7.
Figure 3.7 b.
From this list, choose how points are to be selected. Choose Select from list. The Select points screen appears, see Figure 3.8. This time, it displays a list of points in the Trimble Survey Controller software database.
Figure 3.8 c.
Select points screen – Trimble Survey Controller software database
/
Select points screen – Trimble Survey Controller software database
To select a point from the list, highlight it and press the softkey. A check mark appears next to the selected point name. Do this for each point to be staked out.
Trimble Survey Controller Field Guide
51
Page 66
3 d.
B
\
After selecting the points, press to return to the Stakeout/Points screen. Select the next point to be staked out. To do this, highlight the point and press .
Tip – To practice before there are points in the database, measure a point and move away from it. Follow Step 1 through Step 3, using the point you measured as the stakeout point. For more information see Measuring a Point, page 42.
4.
Make sure the survey is initialized (For more information, see Initializing the Survey, page 40).
5.
In the Survey/Stakeout/Point screen, enter a value in the softkey or . The Antenna height field and press the azimuth and horizontal distance from the present position to the point to be staked out appear, together with a graphical representation of these values, as shown in Figure 3.9.
x
Figure 3.9
6.
52
\
RTK Field Procedures
\
Stakeout/Point graphical display screen – arrow
The azimuth and distance to the next point appear on the right of the screen.
Trimble Survey Controller Field Guide
Page 67
RTK Field Procedures
3
To navigate using the arrow in the graphical display screen, move forwards with the TSC1 data collector held in front of you. The arrow points in the direction of the point to be staked out. Walk towards the point. When you are about three meters or 10 feet from the point, the display changes. Two concentric circles (resembling a bull’s-eye) show the position of the point, and a cross shows your position, as shown in Figure 3.10.
Figure 3.10
F
Stakeout/Point graphical display screen – concentric circles (bull’s-eye)
When you get closer to the point, press to go into Fine mode. The graphical display screen zooms in and magnifies the display. Walk towards the point until the cross on the screen is over the two concentric circles. Remember to keep the pole vertical. Mark the point with a stake or nail as required, and press to return to the Stakeout/Points screen. 7.
=
Do one of the following: –
– sm
To record the as-staked point, place the range pole over it. When the range pole is centered and vertical, press to measure the point (see page 42). Press to store the point, then to return to the Select/Points screen.
=
=
If you do not want to measure the as-staked point, press to return to the list. Stake out more points.
Trimble Survey Controller Field Guide
53
Page 68
3
RTK Field Procedures
3.8
Ending the Survey When you have measured or staked out all the points you need, end the survey:
y
1.
From the Survey menu, select End survey.
2.
to confirm the instruction. The Trimble Survey Press Controller software asks if you want to power down (turn off) the receiver. Press again.
y
Note – Turn off the TSC1 data collector before disconnecting the equipment.
y y
3.
Return to the base station and connect the TSC1 data collector to the receiver. Once again, select Survey / End survey.
4.
Press to confirm the instruction.
The Trimble Survey Controller software asks if you want to power down (turn off) the receiver. 5.
54
Press again.
Trimble Survey Controller Field Guide