Page 69

CHAPTER

4 4

Conventional Instrument Field Procedures In this chapter: ■

Introduction

■

Creating a new job

■

Configuring the job

■

Connecting to a conventional instrument

■

Selecting a survey style

■

Performing a station setup

■

Measuring a Point

■

Measuring rounds of observations

■

Stakeout

■

Ending the survey

Page 70

4

Conventional Instrument Field Procedures

4.1

Introduction This chapter guides you through a basic field survey using the Trimble Survey Controller software with a conventional instrument. It shows how to:

B 4.2

• create a job

• configure the job

• connect the equipment

• select a Survey Style

• do a station setup

• measure a point

• measure rounds of observations

• stake out a point

• end the survey

Tip – For more information on any topic covered in this manual, refer to the Trimble Survey Controller Reference Manual.

Creating a New Job To create a job:

56 w O

1.

Turn on the TSC1 data collector.

2.

From the main menu, select Files / Job management.

3.

Press the

4.

Type the job name and press

5.

If a PCMCIA (PC) card is inserted and you want to record data on it, set the File location field to PC card.

6.

Press the softkey.

softkey.

Trimble Survey Controller Field Guide

\ to accept it.

Page 71

Conventional Instrument Field Procedures

7.

4

The Select coordinate system screen appears. Do one of the following: –

Choose a coordinate system from the list. To do this, choose Select from library and select a system from the list. Select the zone for the system. Set the Use geoid model field to No.

–

Key in the datum transformation and projection parameters for the site.

\\

To do this, select Key in parameters then Datum transformation and enter the details for the site. Press then select Projection and enter the details. Press again to accept the details. –

,

Select Scale factor only. Select this option if you are doing a survey that will contain only conventional instrument observations. Note – If you intend to combine the GPS measurements with conventional observations later, choose a coordinate system now. Do not select Scale factor only.

–

8.

4.3

Copy a coordinate system from another job in the database. To do this, select Copy from other job and select the job name to copy from.

Press

O to create the job.

Configuring the Job Configure the job just created to display the correct units, and the correct time and date. For more information, see Configuring the Job, page 28.

Trimble Survey Controller Field Guide

57

Page 72

4

Conventional Instrument Field Procedures

4.4

Connecting to a Conventional Instrument This section shows how to assemble the equipment to do a survey with a conventional instrument. The Trimble Survey Controller software interfaces with the following brands of conventional instruments: •

Trimble

•

Leica

•

Geotronics (Spectra Precision)

•

Nikon

•

Pentax

•

Sokkia SET

•

Topcon

•

Zeiss

To assemble the equipment, see Figure 4.1 (or Figure 4.2, depending on the equipment) then do the following:

C C

58

1.

Set up the conventional instrument on a tripod.

2.

Connect the TSC1 data collector to the instrument using the 0-shell Lemo to 0-shell Lemo cable. If using a third-party conventional instrument, connect the TSC1 data collector to the instrument using the 0-shell Lemo to DB9 cable connected to the instrument download cable.

Warning – Do not force plugs into the ports. Align the red dot on the plug with the red line on the socket and insert the plug carefully.

Warning – Before connecting the TSC1 data collector to a Leica or Geodimeter instrument, select the appropriate Survey Style. This Survey Style must specify the correct type of instrument. If you do not do this, the Trimble Survey Controller will not connect to the instrument and the instrument will have to be reset.

Trimble Survey Controller Field Guide

Page 73

Conventional Instrument Field Procedures

3.

4

Turn on the TSC1 data collector and go to Selecting a Survey Style, page 61.

Figure 4.1 shows the TSC1 data collector connected to a Trimble conventional instrument.

F1

F2 F4

Figure 4.1

F3

F4

7 4 1 0

8 5 2 .

9 6 3 +/-

TSC1 connected to a Trimble conventional instrument

Trimble Survey Controller Field Guide

59

Page 74

4

Conventional Instrument Field Procedures

Figure 4.2 shows the standard connection to a third-party conventional instrument.

To conventional instrument

TSC1

Figure 4.2

60

Standard connection to a third-party conventional instrument

Trimble Survey Controller Field Guide

Page 75

Conventional Instrument Field Procedures

4.5

4

Selecting a Survey Style To select a conventional Survey Style, do the following: 1.

From the main menu, select Survey. The Select Survey Style menu appears. Note – A Survey Style is a set of configurations that apply to one particular type of survey. Each Survey Style provides a pattern or template that you can use when performing a survey of that type. For a conventional survey, the Survey Style defines the type of instrument used and the parameters needed for measuring and storing points.

Y

2.

Highlight Trimble Conventional and press the

3.

In the To name field, type a name for the new Survey Style (for example, Test conventional).

4.

If a PCMCIA (PC) card is inserted, choose whether to store the new Survey Style on the PC card or in the main memory.

5.

Press

\ softkey.

E to add the new Style to the menu of Survey Styles.

\ O and select If you are using a third party instrument, press the Instrument option in the Survey Style. From the Manufacturer and Model (optional) fields, select the instrument you are using. Press then to return to the Select Survey Style menu. For more information on configuring a conventional Survey Style and your conventional instrument see Appendix E Conventional Instrument Settings.

\

6.

Highlight the name of your new Survey Style and press The Survey menu appears.

7.

Turn on the instrument.

8.

Perform a station setup. For more information see the next section.

Trimble Survey Controller Field Guide

.

61

Page 76

4

Conventional Instrument Field Procedures

4.6

Performing a Station Setup Before making any measurements or staking out any points, perform a station setup. Set up the equipment. If you have not yet created and configured a job, do so now. See Creating a New Job, page 56, and Configuring the Job, page 57. Select your new Survey Style, (for more information, see Selecting a Survey Style, page 61), then do the following: 1.

From the Survey menu, select Station setup. The Survey/Station setup screen appears.

2.

Enter the station point name in the Instrument point name field.

C k

Note – If you have not already keyed in or uploaded the softkey and coordinates of the instrument point, press the key them in now. If you do not know the coordinates of the instrument point, press and key them in later. 3.

Enter the height of the instrument in the Instrument height field. Note – For a two-dimensional or planimetric survey, the Instrument height field can be left as null (?). No elevations will be calculated.

4.

Enter the backsight point name in the Backsight point name field.

yn

Note – If the backsight point is not in the Trimble Survey Controller software database, a message appears, asking if you or as required. want to key in the point. Press If the backsight coordinates are stored in the Trimble Survey Controller software, the azimuth is automatically calculated and inserted in the Azimuth field. The field name changes to Azimuth (Computed). If the backsight coordinates are not stored in the database, you can key in a value in the Azimuth field. The field name changes to Azimuth (Keyed in).

62

Trimble Survey Controller Field Guide

Page 77

Conventional Instrument Field Procedures

5.

o

4

Enter the height of the backsight target in the Backsight height field. Note – To enter a prism constant, press the a value in the Prism constant field.

softkey. Enter

It is also possible to enter values for various corrections in the Options screen. 6.

Choose one of the following options from the Method field, : –

Angles only – measures the horizontal and vertical angles

–

Angles and distance – measures the horizontal and vertical angles and slope distance

Note – If you choose Angles only and the backsight point is not yet stored in the database, no coordinates are calculated for it. A screen similar to the one shown in Figure 4.3 appears.

Figure 4.3

7.

Survey/Station setup screen

Sight the center of the backsight target and press m

.

Trimble Survey Controller Field Guide

63

Page 78

4

Conventional Instrument Field Procedures

8.

The distance deltas are displayed on the screen, as shown in Figure 4.4.

Figure 4.4

9.

Survey/Station setup screen – after measurement taken

)

A small arrow in the top right corner of the screen indicates that there is more information than can be shown in one screen. Press the key repeatedly to see the measurement information in the next screen.

10. Do one of the following:

64 s

–

If the measurement information is correct, press the softkey to accept the station setup. The station setup is finished.

– then If you do not want to use the measurement, press the softkey to abandon it. Repeat Step 7 and Step 8 to take another measurement.

y

Trimble Survey Controller Field Guide

=