Page 21
CHAPTER
2 2
The TSC1 Data Collector In this chapter: ■
Introduction
■
Operating the TSC1 data collector
■
Sample screen displays
■
Trimble Survey Controller software menu structure
■
Data entry/editing
■
Reviewing data
■
Online help
■
Rebooting
Page 22
2
The TSC1 Data Collector
2.1
Introduction The Trimble Survey Controller software simplifies surveying by configuring and controlling receivers for GPS surveys, and by communicating with conventional instruments for conventional surveys. The Trimble Survey Controller software makes surveying a faster and more efficient process because it: • stores points
• simplifies stakeout tasks
• performs numerous calculations, including calibration and coordinate geometry (Cogo) functions
• permits two-way data transfer operations
For GPS surveys, it also: • configures the necessary receiver parameters
• monitors the receiver and radio status
This chapter introduces the TSC1 data collector, and shows how to use the keys and enter data. It gives an overview of the Trimble Survey Controller software menu structure and shows some sample screens. A good way to learn how to use the software is to take the TSC1 data collector into the field. Become familiar with the keypad, press various keys, look through the menus, and use the online help. Before going into the field, make sure you have everything you need.
8
Trimble Survey Controller Field Guide
Page 23
The TSC1 Data Collector
2
Figure 2.1 and Figure 2.2 will help you to get started.
PC card (optional)
Function keys
Multi-directional arrow key
Backspace key
Second function key
Space key
Caps lock key
On/Off key
Help key
To receiver Power/data cable
Figure 2.1
Front view of the TSC1 data collector
Trimble Survey Controller Field Guide
9
Page 24
2
The TSC1 Data Collector
Top port PC card cover release button
Battery cover
Battery cover screw
Bottom port
Power/data cable Figure 2.2
10
Back view of the TSC1 data collector
Trimble Survey Controller Field Guide
Page 25
The TSC1 Data Collector
2.2
Operating the TSC1 Data Collector
2
|
Make sure the battery is inserted. Press the green key to turn on the TSC1 data collector. Hold down the same key for one second to turn it off.
2.2.1
Keys
123abc\=* _( ) ( *
Hard keys are the physical keys on the TSC1 keypad. Examples of these are , , , , , , , , , , , and . Use these keys to enter data and to access different screens. When using hard keys to enter data, press the key to access the beginning of a highlighted field, to access the end of it.
Alternate keys give some hard keys a second function. Some second functions are displayed in yellow on the hard keys. To use a second key and then press the key that has the second function, press the function you want.
[
For a complete list of second functions, refer to the Trimble Survey Controller Reference Manual. Use second functions to move quickly around the TSC1 screen. Table 2.1 lists some of them. Table 2.1
Second function keys
Press ...
To go ...
Also called ...
[)
down a page
Page down
[_ up a page
Page up
[* to the beginning of a list
Home
[( to the end of a list
End
[N to the previous screen
Previous
!@#$
Softkeys are displayed on the bottom line of the TSC1 screen. A softkey corresponds to the function key adjacent to it: , , , or . To activate a softkey, press the relevant function key.
,
Trimble Survey Controller Field Guide
11
%
Page 26
2
> \ m
The TSC1 Data Collector
Note – The softkey appears if there are more than five softkeys associated with a screen or field. Press it to see the others.
\ key has the same effect as For some operations, pressing the pressing a softkey. When measuring a point, for example, press the key or the softkey to start measuring the point.
U
Some softkeys only appear when you access a particular field. In the softkey appears. It relates Antenna height field, for example, the only to this field and is no longer visible when you move to the next field.
2.2.2
Menus Menus list the Trimble Survey Controller software functions. When the TSC1 data collector is turned on, the Trimble logo screen appears. This is immediately followed by the main menu. Note – To return to the main menu at any time, press the
_ *
M key.
) (
To select a menu item, use the arrow keys to move to the required field: press the or key to move up the list and press the or key to move down the list. Press to select the highlighted item.
B
\
Tip – To select an item quickly, type the first letter of its name. If only one item in the menu starts with that letter, typing the letter takes you to the field and displays the screen box for that field.
) (
If more than one item starts with the same letter, type the letter once to go to move down the list. to the first of these items, then press or Alternatively, type the first letter twice to go directly to the second item. See Table 2.1 on page 11 for more keypad shortcuts.
12
Trimble Survey Controller Field Guide
Page 27
The TSC1 Data Collector
2.3
Sample Screen Displays
2
|
To turn on the TSC1 data collector, press the green key. The Trimble logo screen appears, followed by the main menu. The Trimble Survey Controller software is menu driven. This means that you select an item from a list to perform a function. The main menu consists of six icons. All other menus appear as lists. Most of the details in the status line only appear when the TSC1 data collector is connected to either a GPS receiver or a conventional instrument. Figure 2.3 shows the main menu screen that appears if the TSC1 is connected to a GPS receiver.
Screen title shows current job name
Icon
TSC1 power level indicator Status line External power level indicator
Softkey area Number of SVs tracked PC card indicator
Figure 2.3
Main menu – TSC1 data collector connected to GPS receiver
Trimble Survey Controller Field Guide
13
Page 28
2
The TSC1 Data Collector
Figure 2.4 shows the screen that appears if the TSC1 is connected to a conventional instrument. Screen title shows current job name
Icon TSC1 power level indicator Instrument circle readings Indicates that the TSC1 is connected to a conventional instrument Figure 2.4
2.3.1
Station setup icon Target icon with height
Main menu – TSC1 data collector connected to conventional instrument
Selecting a Menu Item
\
*(_ )
Use the arrow keys , , , or to move around a menu, then press the key to complete the selection. The screen changes to display the menu for the chosen item. If a screen has softkeys, these appear in the area below the status line.
14
Trimble Survey Controller Field Guide
Page 29
The TSC1 Data Collector
2
Practice To practice using the Trimble Survey Controller software, follow these steps: 1.
From the main menu, select Files, then Job management. The Select job screen appears, as shown in Figure 2.5.
Scroll bar shows position in list (top) and list size
Job list
Softkey Figure 2.5
Job list and softkeys
2.
To select a job, highlight the required job and press
\
.
The first time you use the Trimble Survey Controller software, this list of jobs is empty. To create a new job, see Creating a New Job, page 26.
=
3.
Press the
4.
Select Survey.
E key to return to the main menu.
A list of Survey Styles appears.
% \
5.
Highlight Trimble RTK and press the to the softkey).
6.
Highlight Rover options and press key (this corresponds
.
Trimble Survey Controller Field Guide
15