For the Trimble TSC1

Page 15

CHAPTER

1 1

Surveying with GPS In this chapter: ■

Introduction

■

Kinematic surveying

■

Differential surveying

■

FastStatic surveying

Page 16

1

Surveying with GPS

1.1

Introduction This chapter introduces you to the use of the Global Positioning System (GPS) as a survey tool. It provides an overview of some of the concepts involved, and lists the different survey techniques that the Trimble Survey Controller™ software supports. These concepts and techniques are covered in more detail in the two-volume Trimble Survey Controller Reference Manual. High precision GPS surveying requires two or more GPS receivers. One receiver is located over a known control point for the duration of the survey. It is called the base receiver or base. The other receivers are called roving receivers or rovers. They are moved to the points that you are to survey or stake out. It is possible to use more than two GPS receivers for some surveys, but this manual limits discussion to simple survey configurations that use two GPS receivers: the base receiver and one roving receiver. Conduct GPS surveys in real time, or postprocess them: •

Real-time surveys use a radio system to transmit measurements from the base receiver to each rover, where they are processed. Results are available while surveying - ‘in real time’.

•

Postprocessed surveys use measurements that are stored in the receiver or in the TSC1™ data collector for processing at a later time. Use Trimble’s office computer software, such as Trimble Geomatics Office™, Trimble Survey Office™ or GPSurvey™ software, to process stored data.

Note – If you are using postprocessed techniques, make sure that you have the appropriate module of the Trimble Geomatics Office software to process the data. The Trimble Survey Controller software controls three GPS survey techniques:

2

•

Kinematic

•

Differential

•

FastStatic

Trimble Survey Controller Field Guide

Page 17

Surveying with GPS

1

The Kinematic and Differential techniques are suitable for real-time or postprocessed surveys. The FastStatic™ technique is suitable for postprocessed surveys only. Note – Use real-time techniques for stakeout operations.

1.2

Kinematic Surveying Kinematic (Stop and Go) surveying uses GPS phase measurements from four or more satellites common to both the base and rover receivers. To achieve centimeter-level precision the survey must first be initialized. There are different ways to achieve initialization: •

With single-frequency receivers, initialize real-time surveys by setting the rover over a known point or by using an initializer bar. Initialize postprocessed surveys over a new point or a known point.

•

With dual-frequency receivers, initialize real-time surveys by setting the rover over a new or known point, or by using an initializer bar. Initialize postprocessed surveys over a new point or a known point. With dual-frequency receivers that have the On-The-Fly (OTF) option installed, surveys are initialized automatically while the rover is moving. You cannot initialize on a new point if the receiver has OTF.

If the number of common satellites falls below four while you are surveying, reinitialize the survey when four (or more) satellites are again being tracked. If using OTF, wait until five satellites are being tracked.

Trimble Survey Controller Field Guide

3

Page 18

1

Surveying with GPS

1.3

Differential Surveying Differential surveying calculates positions using GPS C/A-code measurements. Differential surveys do not require initialization or continuous tracking of satellites. Results typically achieve submeter precision.

1.4

FastStatic Surveying FastStatic surveying is a centimeter-level precise, postprocessed method that uses GPS phase measurements to measure baselines in as little as eight minutes. The time required depends on the receiver type, the baseline length, the number of satellites (SVs) available, and the satellite geometry. Static surveying is used for surveys of the highest precision, but it requires occupation times of one hour or longer. FastStatic surveying is derived from Static surveying, and is the result of advances in both hardware and software development.

4

Trimble Survey Controller Field Guide

Page 19

Surveying with GPS

1

Table 1.1 summarizes the different survey techniques. Table 1.1

Characteristics of a GPS survey

Procedure

Minimum number of SVs

Minimum observation time

Typical horizontal Other characteristics precisions

Static

4

1 hour

Single-frequency: ±5 mm + 1 ppm Dual-frequency: ±5 mm + 0.5 ppm

For single-frequency receivers, best precision is on baselines of ≤10 km. For dual-frequency receivers, there is no maximum baseline length.

FastStatic

4

8–30 minutes

Varies between static and kinematic precisions, depending on occupation time.

Procedure is the same as for Static, but observation times are shorter.

Postprocessed kinematic

4

2 epochs

±1 cm + 1 ppm

Baseline limit is approximately 50 km. Receiver needs five satellites to initialize on the fly. Rover must be initialized for centimeter-level precisions.

Trimble Survey Controller Field Guide

5

Page 20

1

Surveying with GPS

Table 1.1

Characteristics of a GPS survey

Procedure

Minimum number of SVs

Minimum observation time

Typical horizontal Other characteristics precisions

Real-time 4 kinematic (RTK)

1 epoch

±1 cm + 1 ppm

Radio link is required. Baseline limit is approximately 10 km. Receiver needs five satellites to initialize on the fly. Rover must be initialized for centimeter-level precisions.

Postprocessed differential

2 epochs

Everest / Maxwell receivers: <0.5 m RMS with 5 SVs, PDOP <4

Satellites do not have to be tracked continuously.

4

Other receivers: 1–3 m in same conditions. Real-time differential

4

1 epoch

Everest / Maxwell receivers: 0.2 m + 1 ppm RMS with 5 SVs, PDOP <4

Radio link is required. Satellites do not have to be tracked continuously.

Other receivers: 1–3 m in same conditions. Values in this table assume a low multipath environment and low ionospheric activity. They are based on results obtained using the latest Trimble equipment.