The text of a manual · part 6 of 14
Trimble Survey Controller Field Guide: The TSC1 Data Collector, pages 30 to 38
Pages 30 to 38 of 114, from Trimble Survey Controller Field Guide
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSC1
Page 30
2
The TSC1 Data Collector
The Rover options screen appears, see Figure 2.6. Arrow shows that you chose the entry for this field from a list
Figure 2.6
RTK Rover options screen
7.
Press
=
, then press the
O softkey.
You return to the Survey Style menu for the chosen Style. 8.
If the TSC1 data collector is connected to a receiver, press The Survey menu appears.
9.
Select Measure points and press
\
\
.
.
If this is the first time you have used this Survey Style, the Style wizard prompts you to select the type of antenna and the type of radio used.
\
10. From the list that appears on the screen, highlight the type of . antenna you are using and press
\
11. From the next list that appears, highlight the type of radio you . are using and press
16
Trimble Survey Controller Field Guide
Page 31
The TSC1 Data Collector
2
The Survey/Measure points screen appears, see Figure 2.7. Screen title Typical field title
Radio icon
Horizontal and vertical precisions
Static icon
Survey method (RTK) and mode (Fixed)
Figure 2.7 o
Survey/Measure points screen showing fields and status line
In a real-time kinematic survey, an RMS indicator appears as text above the softkey when the receiver is not static (when you are not measuring a point). It disappears when the receiver is in Coarse mode during stakeout.
B 2.4
Tip – If the TSC1 data collector is not connected to a receiver, use Figure 2.7 to familiarize yourself with the Survey/Measure points screen.
Trimble Survey Controller Software Menu Structure For an overview of the entire Trimble Survey Controller software menu structure, see Figure 2.8. Keep this figure handy as a reference until you are familiar with the menu structure.
Trimble Survey Controller Field Guide
17
Page 32
2
The TSC1 Data Collector
Files Job management Review current job Map of current job Status of current job Copy data between jobs Import / Export File manager
Trimble PC communications Send ASCII data Receive ASCII data
Key in Points Lines Curves Boundary Roads Templates Notes
Survey – Items depend on the type of survey you are doing Start base receiver Station setup Start survey Start/Stop PP infill Measure points Measure rounds Continuous topo Offsets Measure laser points Stakeout Initialization Swap base receiver Site calibration End survey Figure 2.8
Points Lines Curves DTMs Roads
Trimble Survey Controller software menu structure This figure continues on page 19.
18
Trimble Survey Controller Field Guide
Page 33
The TSC1 Data Collector
2
Configuration Job Controller Feature & attribute libraries Survey Styles
Coordinate system Units Cogo settings
Time/date Language Hardware
Cogo Inverse Intersections Traverse Subdivide a line Subdivide a curve Compute area Compute azimuth Compute distance
Instrument Items depend on the type of instrument the TSC1 is connected to Satellites Position Copy receiver files Receiver status Options Remote controller Navigate to point Station setup details Target Instrument controls
Items depend on the Survey Style selected Rover options Topo point Rover radio Base options Base radio
Laser rangefinder FastStatic point Observed control point Rapid point Continuous points Stakeout Target Site calibration PP initialization times Duplicate point actions Instrument Corrections Traverse options
Trimble Survey Controller Field Guide
19
Page 34
2
The TSC1 Data Collector
2.5
Data Entry/Editing Data must be entered before the Trimble Survey Controller software can perform most of its functions. A typical screen has several fields into which you can enter data. For some fields you select an option from a list, while for others you key in alphanumeric details.
2.5.1
Choosing an Option
(
For some fields, you select a parameter setting from a list of options. These fields have a symbol on the left (see Figure 2.6 on page 16).
(
There are two ways to select an option:
\_ )
•
Press the key when the field is highlighted. The options appear in a pop-up list box. Use the or key to move to the required setting and then press . This accepts the setting and moves the cursor to the next field.
•
Press the key when the field is highlighted. The pop-up list box does not appear. Instead, a value is displayed in the field. To change this value, press again. Press it repeatedly until you reach the option that you want. (When you use this method, the Trimble Survey Controller software cycles through the options for the current field, starting at the bottom of the list.) When you reach the required option, press to move to the next field, or to move to the previous field.
*
*
)
2.5.2
Keying In Data
_
(
To enter data, highlight the field and press the key. This takes you to the beginning of the field. Key in the details. When the details are complete, press or the key to move to the next field. Press again to accept the screen.
\
20
Trimble Survey Controller Field Guide
)
\
Page 35
The TSC1 Data Collector 2.5.3
2
( [S
Editing Data
To edit details in a field, highlight the field and press the key. Then use the left and right arrow keys to move around inside the field. If necessary, press to delete a character, and to create a space.
[B
2.6
Reviewing Data You can review the data in the Trimble Survey Controller software database at any time. To review data, select Files from the main menu. Then select Review current job.
p P _ ) ; æ ; \
Records are stored in chronological order. The last (most recent) page of the database appears first when you access the database. and softkeys to move up and down in the Press the database one page at a time. Press the and keys to move up and down one record at a time. Alternatively, use the second function keys. For a list of these, see Table 2.1 on page 11. softkey to find records elsewhere in the database. For Use the example, it is possible to search for points surveyed several hours ago. To access the Search menu, press . Select a type of search. You can choose to repeat a previous search, or to search by name, code, or current record type. If required, enter the point name or the code then press the softkey to search up the database or to search down the database.
=
For more information about a record, highlight it and press return to the database list, press .
\
. To
It is possible to edit some of the fields, such as Code and Antenna height. Note – If point coordinates appear as ‘?’, see the Note on the next page.
Trimble Survey Controller Field Guide
21
Page 36
2
The TSC1 Data Collector
2.6.1
Coordinate View Setting The setting in the Coordinate view field (WGS-84, Local, Grid, or HA VA SD, for example) determines which values appear in the point record. You can change the coordinate view setting for an entire job, or just when viewing a point. To change the Coordinate view setting for a point that you want to view:
\ o
1.
When reviewing the database, highlight the point record and . press
2.
Press and set the Coordinate view field as required.
Note – If no datum transformation and no projection are defined and the Coordinate view field is set to Local or Grid, the coordinate values for GPS points will be ‘?’. Change the Coordinate view setting to WGS-84.
2.7
Online Help To get more information about a topic, press the An alphabetic list of topics appears.
_ )
?
pP key at any time.
or Press the or keys to move to a topic, or use the softkeys. The structure of the Help list of topics reflects the structure of the Trimble Survey Controller software menus. Information about staking out a point, for example, is under Stakeout / Point.
B
22
Tip – To move quickly to a Help topic, type the first few letters of the topic. Then use the arrow keys if necessary.
Trimble Survey Controller Field Guide
Page 37
The TSC1 Data Collector
\
2
)
Press to access the information on the selected topic. A screen of text appears. For some topics there is also a graphics screen. Press to see it. See Figure 2.9.
Figure 2.9
Online help screens
Some topics have more than one screen of information. This is indicated by a small arrow in the top right corner of the screen. For these topics, press or to see the next screen. Press to return to the Help list of topics.
( )
=
=
To exit the online help system, return to the Help list of topics and . press
2.8
Rebooting If the Trimble Survey Controller software fails to respond to keystrokes, it may be necessary to reboot the system. Turn off the TSC1 data collector and turn it back on again.
| for five seconds, then release it. If this does not work, hold down Press it again to turn on the TSC1 data collector. If this does not work, perform a warm boot. Note – If the software fails to respond to keystrokes, first check that the TSC1 is receiving power.
Trimble Survey Controller Field Guide
23
Page 38
2 2.8.1
The TSC1 Data Collector
Warm Boot A warm boot shuts down the hardware and restarts the Trimble Survey Controller software. Note – No data is lost during a warm boot. To perform a warm boot: 1. 2. 3.
| B
Turn off the TSC1 data collector. It may be necessary to hold key for five seconds. down the Hold down while pressing and releasing the key. This turns on the TSC1 data collector.
B
|
. The TSC1 restarts and, When you hear three beeps, release a few seconds later, runs the Trimble Survey Controller software.
Note – A warm boot restores the Trimble default settings. If the warm boot fails, perform a cold boot. 2.8.2
Cold Boot A cold boot erases the internal memory and restarts the Trimble Survey Controller software. It does not affect the PCMCIA (PC) card.
C
Warning – A cold boot loses all data in the internal memory. Only perform one if a warm boot fails.
To perform a cold boot: 1. 2.
| |[ %
Turn off the TSC1 data collector. It may be necessary to hold key for five seconds. down the Hold down the and keys together while pressing and releasing . This turns on the TSC1 data collector. After a few seconds a message appears:
[ %
Force Reformat Internal Media Please Wait......
3.
24
Release the and keys. After a few minutes, the Trimble Survey Controller software starts.
Trimble Survey Controller Field Guide