The text of a manual · part 12 of 14

Trimble Survey Controller Field Guide: FastStatic Surveying

Pages 89 to 96 of 114, from Trimble Survey Controller Field Guide

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSC1

Page 89

CHAPTER

5 5

FastStatic Surveying In this chapter: ■

Introduction

■

Creating a new job

■

Configuring the job

■

Setting up the base station

■

Setting up the rover

■

Reviewing data

Page 90

5

FastStatic Surveying

5.1

Introduction Use a Trimble FastStatic survey to obtain results that are more precise than those obtained from a real-time survey. As FastStatic surveying is always a postprocessed operation, no radios are required. Note – If you are using postprocessed techniques, make sure that you have the appropriate module of the Trimble Geomatics Office software to process the data. To complete a FastStatic survey you need to: • create a new job (see page 26)

• configure the job (see page 28)

• set up the base receiver

• set up a rover receiver and measure points

• end the survey (see page 54)

• review the data in the TSC1 data collector (see page 21)

Most of these operations are common to all Survey Styles. For more information see Chapter 3, RTK Field Procedures.

B 5.2

Tip – For more information on any topic covered in this chapter, refer to the Trimble Survey Controller Reference Manual.

Creating a New Job To create a new job, see page 26.

5.3

Configuring the Job To configure the job, see page 28.

76

Trimble Survey Controller Field Guide

Page 91

FastStatic Surveying

5.4

5

Setting up the Base Station Locate the base station where there is a clear and uninterrupted view of the sky, for example on top of a hill or building. You should be able to see the sky all around at an elevation angle of 13° above the horizon. To set up the base station for a FastStatic survey: 1.

Set up the antenna over the base station survey point using a tripod, tribrach, and tribrach adaptor.

2.

Connect the receiver as shown in Figure 5.1 (or Figure 5.2, depending on the receiver type).

Note – You do not need a radio connection for a FastStatic survey.

Trimble Survey Controller Field Guide

77

Page 92

5

FastStatic Surveying

Figure 5.1 shows how to connect a GPS Total Station 4800 receiver for a FastStatic survey.

GPS Total Station 4800 receiver TSC1

Power supply

Figure 5.1

78

TSC1 connected to a GPS Total Station 4800 receiver (FastStatic survey)

Trimble Survey Controller Field Guide

Page 93

FastStatic Surveying

5

Figure 5.2 shows how to connect a GPS Total Station 4700 receiver for a FastStatic survey. Antenna

TSC1

GPS Total Station 4700 receiver 2

1

3

›

1

›

2

3

2

Power supply

Figure 5.2

TSC1 Connected to a GPS Total Station 4700 receiver (FastStatic Survey)

Trimble Survey Controller Field Guide

79

Page 94

5 5.4.1

FastStatic Surveying

Starting the Base Survey To start the survey: 1.

From the main menu, select Survey. The Select Survey Style menu appears. Note – If a survey is running, the Select Survey Style menu does not appear. If the current survey is not FastStatic, end it (see page 54) and return to Step 1.

2.

Do one of the following: –

Y

If this is the first FastStatic survey with the current equipment: softkey. Highlight Trimble FastStatic and press the In the Style name field, type a name for the new FastStatic Survey Style to be created (for example, Test FastStatic) and press . Press again to return to the Select Survey Style menu.

\ \

E \ O

With the new FastStatic Survey Style still highlighted, softkey. Select Rover options and change press the the Logging device field to Receiver or Handheld as required. Select a value in the Logging interval field and set the Antenna type field to the type of antenna you are using. Press and do the same for Base options. Press the appears. – softkey, then

\

\

. The Survey menu

If this is not the first FastStatic survey with the current equipment, highlight your FastStatic Survey Style and press .

\

3.

From the Survey menu, select Start base receiver.

4.

Enter the point name and press

.

If the point does not yet exist in the database, a message appears: Point does not exist. Provide coordinates at processing time

80

Trimble Survey Controller Field Guide

Page 95

FastStatic Surveying

5

With FastStatic surveys you can use known, published, or measured values to enter WGS-84 coordinates for the base station into the TSC1 data collector. Alternatively, enter coordinates for the base station when you postprocess the data.

m

5.

Enter values in the Code and Antenna height fields.

6.

Make sure the antenna is centered and vertical over the control softkey or . The TSC1 data point, then press the collector starts to record data. Do one of the following: –

\

If you are logging data in the receiver a message appears: Base started. Disconnect data collector from receiver.

Disconnect the TSC1 data collector but do not turn off the receiver. –

5.5

If you are logging data in the TSC1 data collector, the Base screen appears. It shows what point is being surveyed and the time elapsed since data logging started. Leave the TSC1 connected to the base receiver, and set up the rover using another TSC1.

Setting up the Rover To set up the rover receiver for a FastStatic survey: 1.

Set up the antenna using a tripod, tribrach, and tribrach adaptor. The antenna must have a clear view of the sky.

2.

Connect the hardware as shown in Figure 5.1 (see page 78) or Figure 5.2 (see page 79), depending on the receiver type.

Note – You do not need a radio connection for a FastStatic survey.

Trimble Survey Controller Field Guide

81

Page 96

5

FastStatic Surveying

5.5.1

Starting the Rover Survey To start the survey: 1.

\

From the main menu, select Survey. From the Select Survey Style menu, select your new FastStatic Survey Style. Press . For more information, see page 80. Note – If a survey is running, the Select Survey Style menu does not appear. If the current survey is not FastStatic, end it (see page 54) and return to Step 1.

2.

Select Measure points.

3.

Enter values in the Point name, Code, and Antenna height fields.

4.

Make sure the antenna is centered and vertical over the control softkey or . The data collector point, then press the starts to record data.

m

\

Note – The antenna should be on a tripod to keep it vertical and stationary while data is recorded.

s

5.

The Trimble Survey Controller software has preset times for recording a FastStatic point. These times are related to the number of satellites tracked. When the preset time has elapsed, the softkey appears. Press it to store the point.

6.

Move to another point. Repeat Step 3 through Step 5 until all the points are measured. Note – There is no need to maintain lock on satellites when moving between points.

7.

5.6

End the survey (see page 54).

Reviewing Data To review the data in the Trimble Survey Controller software database, see page 21.

82

Trimble Survey Controller Field Guide