Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 25 of 32

NEO Hand-Held Computer (Model No. PX750) User Manual: App C: Bar Code Settings, pages 208 to 216

Pages 208 to 216 of 278, from NEO Hand-Held Computer (Model No. PX750) User Manual

The original document is the PDF (7.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix NEO PX750

Page 208

Appendix C: Bar Code Settings UPC A

C.1.9

UPC A Enabled Set this parameter to on to enable UPC A. UPC-A Check Digit If you enable this parameter, the check digit is included with the decoded bar code data. UPC-A Preamble When you double-tap on this parameter, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-A symbols transmitted to the host device: System Char – system character transmitted with the data, Country Code and System Char – both the country code (“0” for USA) and system character are transmitted with the data, or None – no preamble is transmitted. The lead-in characters are considered part of the symbol. Add/Remove Data Refer to “Add/Remove Data” on page 8 for details.

C.1.10

UPC E Enable UPC-E Set this parameter to on to allow UPC E bar code scans. Enable UPC-E1 Set this parameter to on to allow UPC-E1 (zero suppressed) bar code scans. UPC-E and UPC-E1 Check Digit If you enable one or both of these parameters, a check digit is included with the decoded bar code data. UPC-E and UPC-E1 Preamble When you double-tap on one of these parameters, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-E and UPC-E1 symbols transmitted to the host device: System Char – system character transmitted with the data,

C-10

Psion Teklogix NEO Hand-Held Computer User Manual

Page 209

Appendix C: Bar Code Settings UPC/EAN Shared Settings

Country code and System Char – both the country code (“0” for USA) and system character are transmitted with the data, or None – no preamble is transmitted. The lead-in characters are considered part of the symbol. Conv. UPC-E to UPC-A This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Conv. UPC-E1 to UPC-A This parameter converts UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.11

UPC/EAN Shared Settings The parameters you set here are a shared across all available UPC and EAN bar codes. Enable Bookland EAN Setting this parameter to on allows your scanner to recognize Bookland EAN bar codes. Supplementals Supplementals are additionally appended characters (2 or 5). Double-tapping this parameter displays a list of options. If Ignore is chosen, UPC/EAN is decoded and the supplemental characters are ignored. If Decode is chosen, UPC/EAN symbols are decoded with supplementals. Autodiscriminate works in conjunction with the Supp. Redundancy parameter. Supp. Redundancy With Autodiscriminate selected in the Supplementals parameter, Supp. Redundancy adjusts the number of times a symbol without supplementals is decoded before transmission. When you double-tap on this parameter, a dialog is displayed in which you can enter a value between 2 and 20. A value of 5 or above is recommended when Autodiscriminate is selected and you are decoding a mix of UPC/EAN symbols with and without supplementals.

Psion Teklogix NEO Hand-Held Computer User Manual

C-11

Page 210

Appendix C: Bar Code Settings Code 93

Security Level This parameter controls the tolerance for decoding edge-to-edge UPC/EAN bar codes. Double-tapping on this parameter displays a dialog box in which you can choose a level from 0 to 3. Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. Linear Decode Linear Decode applies to code types containing two adjacent blocks (e.g., UPC-A, EAN-8, EAN-13). When enabled, a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other. 2D UPC Half Block Stitching Setting this parameter to on enables UPC Half Block Stitching for the omnidirectional scanner engine only.

C.1.12

Code 93 Enabled Set this parameter to on to enable “Code 93”, or off to disable it. Set Length L1 and Set Length L2 Lengths for Code 93 can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those bar codes of a specified length. Choosing Two discrete lengths allows you to specify two lengths of bar codes that may be decoded. Length within a range allows you to decode a code type within a specified range from 4 to 55. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C-12

Psion Teklogix NEO Hand-Held Computer User Manual

Page 211

Appendix C: Bar Code Settings Codabar

C.1.13

Codabar Enabled Set this parameter to on to enable “Codabar”. Set Length L1 And Set Length L2 Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those bar codes of a specified length. Choosing Two discrete lengths allows you to specify two lengths of bar codes that may be decoded. Length within a range allows you to decode a code type within a specified range from 5 to 55. CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters. NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.14

MSI Plessey Enabled Set this parameter to on to enable MSI Plessey.

Psion Teklogix NEO Hand-Held Computer User Manual

C-13

Page 212

Appendix C: Bar Code Settings MSI Plessey

Set Length L1 and Set Length L2 Set Length L1 And Set Length L2

Lengths for MSI Plessey can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those bar codes of a specified length. Choosing Two discrete lengths allows you to specify two lengths of bar codes that may be decoded. Length within a range allows you to decode a code type within a specified range from 6 to 55. Check Digits Double-tapping on this parameter displays a dialog box in which you can choose One or Two check digit(s). If this parameter is set to One, it is assumed that the last digit is a check digit. If “Check Digits” is set to Two, it is assumed that the last two digits are check digits. Note: If Two check digits is selected, an MSI Plessey “Check Digit Algorithm” must also be selected. See below for details. Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data. Check Digit Algorithm When the Two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Double-tapping on this parameter displays a dialog box in which you can choose the algorithm to be used: MOD 10/MOD 11 or MOD 10/MOD 10. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C-14

Psion Teklogix NEO Hand-Held Computer User Manual

Page 213

Appendix C: Bar Code Settings Interleaved 2 of 5

C.1.15

Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Set Length L1 and Set Length L2 Lengths for “Interleaved 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those bar codes of a specified length. Choosing Two discrete lengths allows you to specify two lengths of bar codes that may be decoded. Length within a range allows you to decode a code type within a specified range from 4 to 14. Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council). Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data. Convert to EAN 13 If this parameter is enabled, the I 2 of 5 bar code is converted to EAN 13. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.16 GS1 DataBar All GS1 DataBar bar codes encode a GTIN-12 or GTIN-13 in a 14-digit data structure. In order to make the GTIN-12 or GTIN-13 a 14-digit data structure, a leading zero or zeros is filled to the left of the GTIN.

Psion Teklogix NEO Hand-Held Computer User Manual

C-15

Page 214

Appendix C: Bar Code Settings Discrete 2 of 5

Enable GS1 DataBar Omni, Expanded & Limited GS1 DataBar Omni and GS1 DataBar Expanded have omnidirectional scanning capability. GS1 DataBar Limited can only be scanned by a linear hand-held scanning device. They cannot be scanned by omnidirectional scanners. Each of these options can be turned on or off depending on the scanner installed in your hand-held. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.17

Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”. Set Length L1 and Set Length L2 Lengths for “Discrete 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those bar codes of a specified length. Choosing Two discrete lengths allows you to specify two lengths of bar codes that may be decoded. Length within a range allows you to decode a code type within a specified range from 1 to 12. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C-16

Psion Teklogix NEO Hand-Held Computer User Manual

Page 215

Appendix C: Bar Code Settings Composite

C.1.18

Composite Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled. In addition, “Center Bar Code Only” must be disabled. A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. The options available for this parameter represent multi-level components of a composite symbol. Enable CC-C and Enable CC-AB To activate these components, set these parameters to on. Enable TLC-39 This composite component integrates MicroPDF417 with the linear code. Setting this parameter to on enables this parameter.

C.1.19

PDF-417 Enable Setting this parameter to on enables PDF-417 two dimensional (2D) coding. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.20

Micro PDF-417 Enable Setting this parameter to ‘on’ enables Micro PDF-417 bar code scanning. Micro PDF-417 is a multi-row symbology that is useful for applications requiring greater area efficiency but lower data capacity than PDF-417.

Psion Teklogix NEO Hand-Held Computer User Manual

C-17

Page 216

Appendix C: Bar Code Settings Decoded (ISCP)

Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 - if the first codeword is 903-907, 912, 914, 915 ]C2 - if the first codeword is 908 or 909 ]C0 - if the first codeword is 910 or 911 If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 - if the first codeword is 903-907, 912, 914, 915 ]L4 - if the first codeword is 908 or 909 ]L5 - if the first codeword is 910 or 911 Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.2

Decoded (ISCP)

•

C-18

Tap on the Scanner drop-down menu, and choose Decoded (ISCP).

Psion Teklogix NEO Hand-Held Computer User Manual