Page 199

APPENDIX C BAR CODE SETTINGS C.1

Decoded (Internal) Scanners

•

C.1.1

Tap on the Scanner drop-down menu, and choose Decoded (internal).

Options Dot Time (msec) The value selected for Dot Time (msec) determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 msec or 400 msec. A value of 0 (zero) disables the target dot. Laser On Time The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 5 and 99, measured in tenths of seconds.

Psion Teklogix NEO Hand-Held Computer User Manual

C-1

Page 200

Appendix C: Bar Code Settings Decoded (Internal) – Advanced Options

C.1.2

Decoded (Internal) – Advanced Options Scan Mode When you double-tap on this parameter, a dialog box is displayed in which you can choose a scanning mode: Scan beam only, Aim with Scan: 1 trigger pull, Aim with Scan: 2 trigger pulls, Aim with Scan on trigger release, and Continuous Scan Mode. Aim Duration This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0 (zero) disables the aiming dot. Minimum Cancel Time The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off. Power Mode This parameter is a power-saving option. Tapping on it displays a screen listing two power mode options: Continuous Power and Low Power. In Continuous Power mode, the scanner is always on, waiting for a trigger pull or a serial communication. In Low Power mode, the scanner is in a standby state, drawing minimal power until a trigger pull or serial communication wakes it. Keep in mind that while this option is more suitable for battery powered applications, there will be a slight delay while the scanner powers up to scan a bar code. Low Power Timeout To extend laser life, you can select the time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned – a successful decode restores normal blinking. This is only used if the unit’s Trigger Mode has been changed to Continuous On and the unit is in a fixed mount; otherwise, this parameter is not used. When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec., 1 min., 2 min., or 3 min.

C-2

Psion Teklogix NEO Hand-Held Computer User Manual

Page 201

Appendix C: Bar Code Settings Decoded (Internal) – Advanced Options

Parameter Scanning Setting this parameter to on allows the scanner to respond to programming bar codes that can be found in the scanner manual. Scanning these is an alternative way to reprogram some of the scanner features. Important: Psion Teklogix strongly recommends that this parameter only be enabled by personnel with a very strong understanding the scanner and how it operates. Scanning the wrong parameter code can result in an inoperable unit; if this occurs, the unit will need to be shipped to a depot for repair. Linear Security Level This parameter allows you to select the security level appropriate for your bar code quality. There are four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels should be selected for decreasing levels of bar code quality. As security levels increase, the scanner’s decode speed decreases. Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 4. Linear security level 1 specifies that the following code types must be successfully read twice before being decoded: Code Type Length Codabar All MSI Plessey 4 or less D 5 of 5 8 or less I 2 of 5 8 or less Linear security level 2 specifies that all types of codes must be successfully read twice before being decoded. Linear security level 3 specifies that code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Code Type Length MSI Plessey 4 or less D 2 of 5 8 or less I 2 of 5 8 or less

Psion Teklogix NEO Hand-Held Computer User Manual

C-3

Page 202

Appendix C: Bar Code Settings Decoded (Internal) 2D Scanning Options

Linear security level 4 requires that all code types be successfully read three times before being decoded. Bi-Direction Redundancy Note: This parameter is only valid if a” Linear Security Level” is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

C.1.3

Decoded (Internal) 2D Scanning Options Scanning Mode When you double-tap on this parameter, a dialog box is displayed in which you can choose one of the following scanning modes: Smart Raster, Always Raster, Programmable Raster, Slab Pattern, Cyclone Pattern or Semi-Omni Pattern. Raster Height And Raster Expand Rate These parameters determine the laser pattern’s height and rate of expansion. Note: These parameters are only used when either Programmable Raster or Always Raster is assigned to the “2D Scanning Mode” parameter. “2D Raster Height” and “2D Raster Expand Rate” are intended for very specific applications and are usually not required for normal scanning purposes. Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 15.

C.1.4

Decoded (Internal) Data Options Transmit Code ID Char A code ID character identifies the scanned bar code type. In addition to any single character prefix already selected, the code ID character is inserted between the prefix and the decoded symbol. When you double-tap on this parameter, a dialog box is displayed in which you can choose a transmit code: None, AIM, or Symbol.

C-4

Psion Teklogix NEO Hand-Held Computer User Manual

Page 203

Appendix C: Bar Code Settings Code 39

Scan Data Format This parameter allows you to change the scan data transmission format. Double-tapping on Scan Data Format displays the following options from which you can choose a data format: data (as-is), data [S1], data [S2], data [S1][S2], [P] data, [P] data [S1], [P] data [S2], and [P] data [S1][S2]. Prefix [P], Suffix [S1] And Suffix [S2] A prefix and/or one or two suffixes may be appended to scan data for use in data editing. When you double-tap on these parameters, a dialog box is displayed in which you can enter a value from 0 to 255. Delete Char Set ECIs Setting this parameter to on enables the scanner to delete any escape sequences representing Character Set ECIs – Extended Channel Interpretations (also known as GLIs) – from its buffer before transmission. When this parameter is enabled, the scanner transmits data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. ECI Decoder Setting this parameter to on enables the scanner to interpret any Extended Channel Interpretations (ECIs) supported by the scanner. This parameter has no effect on symbols that were not encoded using ECIs. If this parameter is set to off and a symbol that was encoded using an ECI escape is scanned, the scanner transmits the ECI escape followed by the data that was not interpreted.

C.1.5

Code 39 Enabled Setting this parameter to on enables Code 39. Enable Trioptic Code 39 Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies. Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.

Psion Teklogix NEO Hand-Held Computer User Manual

C-5

Page 204

Appendix C: Bar Code Settings Code 39

Convert To Code 32 Note: “Code 39” must be enabled in order for this parameter to function. Setting this parameter to on allows the scanner to convert the bar code from Code 39 to Code 32. Code 32 Prefix Note: “Convert to Code 32” must be enabled in order for this parameter to function. When this parameter is enabled, the prefix character A is added to all Code 32 bar codes. Set Length L1 And Set Length L2 Lengths for Code 39 can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be decoded by your scanner

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 55. Check Digit Verification When this parameter is enabled, the integrity of a Code 39 symbol is checked to ensure that it complies with specified algorithms. Note: Only those “Code 39” symbols that include a Mod 43 check digit are decoded when this parameter is enabled. C-6

Psion Teklogix NEO Hand-Held Computer User Manual

Page 205

Appendix C: Bar Code Settings Code 39

Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Decode Performance If this parameter is enabled, one of three decode levels can be chosen in the Decode Performance Level parameter. Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3. Length Restriction The parameters in this sub-menu allow you to define the length of the bar codes that will be decoded using either the Field Size parameter or the Minimum Size and Maximum Size parameters (see below). The order of operation to either match the Field Size or determine if the length falls between the Minimum Size and Maximum Size is as follows: • • •

Strip the leading and trailing characters. Add the prefix and suffix characters. Count the number of characters remaining to either match the field size or determine if the length falls between the minimum and maximum size.

Field Size

When a value is assigned for this parameter, only bar codes that match the field size exactly can be transmitted. If a value is assigned to this parameter, a Minimum Size and Maximum Size value is not required.

Psion Teklogix NEO Hand-Held Computer User Manual

C-7

Page 206

Appendix C: Bar Code Settings Code 128

Minimum Size And Maximum Size

When a value is assigned to these parameters, only bar code lengths that fall between the minimum and maximum value can be decoded. If values are assigned to these parameters, a Field Size value is not required. Add/Remove Data Prefix Char

This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Suffix Char

This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Strip Leading

This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Note: For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”. Strip Trailing

The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

C.1.6

Code 128 Enabled Set this parameter to on to enable Code 128. Enable GS1-128/GS1 US Previously named UPC/EAN and UCC, these types of bar codes include group separators and start codes. Enable ISBT 128 To successfully scan this variation, Enable ISBT 128 must be set to on.

C-8

Psion Teklogix NEO Hand-Held Computer User Manual

Page 207

Appendix C: Bar Code Settings EAN 13

Decode Performance If this parameter is set to on, one of three decode levels assigned to the Decode Performance Level parameter can be selected. Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 128 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3. Length Restriction Refer to “Length Restriction” on page C-7 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.7

EAN 13 Enabled Set this parameter to on to enable EAN 13. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details.

C.1.8

EAN 8 Enabled Set this parameter to on to enable EAN 8. EAN-8 Zero Extend When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols, making them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format. Add/Remove Data Refer to “Add/Remove Data” on page C-8 for details. Psion Teklogix NEO Hand-Held Computer User Manual

C-9