Page 151

Chapter 5: Configuration Options Tab

Soft Scan Timeout This parameter is used by the SDK “Scan” function (soft-scan: starting a scan session via the SDK function, instead of a physical user trigger press). The value assigned to this parameter determines the soft-scan timeout from 1 to 10 sec. (default is 3 sec.). Scan Log File If this parameter is enabled, the input bar code and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the “Scan Log File” is enabled, there is a slight performance effect when performing multiple scans since the log file is written to persistent storage. 5.14.2.3 Data Handling This option allows you to choose the code page NEO will use to display scanned data – Default Local ASCII or ISO-8859-1 Latin 1. Codepage: Tapping on this option displays a window in which you can define the code page NEO will use.

If you choose Default Local ASCII, the code page of the local OS is used. For example, if the local OS uses double-byte Chinese characters, choosing this option will filter data through the local ASCII of that OS and display it accurately, in this example, using doublebyte characters. If you choose ISO-8859-1 Latin 1, data will be displayed according to the character mapping of this Latin 1 code page, ignoring the local OS code page.

Psion Teklogix NEO Hand-Held Computer User Manual

139

Page 152

Chapter 5: Configuration Translations Tab

5.14.3 Translations Tab The Translations tab allows you to define up to 10 cases, each consisting of up to 10 rules in sequential order. Only one case will be applied to a bar code and a case will only be applied if all rules specified in the case are successful – if a rule within a case fails, the entire case fails.

•

140

In the Translation tab, tap on the Case # to create rules.

Psion Teklogix NEO Hand-Held Computer User Manual

Page 153

Chapter 5: Configuration Translations Tab

•

Tap on the No rule drop-down menu to display the rules.

When you choose a rule, an associated screen is displayed in which you can define the rule.

5.14.3.1 Case Rules The case rules are defined as follows: • • • • •

No rule – ignored. Match at index – matches the match string at a specified index. Match and replace at index – matches the match string at a specified index and replaces/changes it. Replace at index – replaces/changes unspecified data in a given range. Add barcode prefix/suffix – adds a global prefix or suffix. Psion Teklogix NEO Hand-Held Computer User Manual

141

Page 154

Chapter 5: Configuration Translations Tab

• •

Verify barcode size – verifies the bar code size. This rule should generally be assigned first, before creating subsequent rules. Search and replace – replaces all instances of the match string. (Note that this rule cannot fail.) Note: Keep in mind that the effects of previously applied rules must be taken into account when creating subsequent rules. For example, if the bar code size is important, it should be checked before any rules that might change the size are applied.

Translation information about the status of each case/rule is displayed in the scan log file (see “Scan Log File” on page 139) when enabled. This is useful if a case fails, and you are trying to determine why a rule is failing.

142

Psion Teklogix NEO Hand-Held Computer User Manual