Page 141

Chapter 5: Configuration User signal strength. Setting AP Density to Low will cause the radio to wait until the signal strength is significantly low before attempting to connect to another Access Point. Depending on your site configuration – for example, the shelving, the Access Point coverage, etc. – a higher setting may improve through-put, increase and maintain signal strength, and reduce missed transmissions. Radio Power Management When this option is enabled, access points that support it will use Radio Power Management guidelines to control the client (NEO) radio. Access points determine how often the NEO radio enters sleep mode when no activity is detected to reduce power consumption on the client side. Another benefit is that when Radio Power Management is enabled, even when no activity is detected, the access point does not disassociate the NEO (client).

5.10.2 User 5.10.2.1 Internet Explorer Settings This option allows you to customize how your Internet Explorer is displayed and how the tabbing functions.

These Internet Explorer options are designed to make it easier to view and navigate web pages displayed on NEO. Directional Tabbing, Fit-to-Screen and Focus Rectangle When Directional Tabbing is enabled, arrow keys can be used to navigate to various links, text boxes and so on around the page rather than limiting you to the [TAB] key. Fit-toScreen reformats the web page on the NEO screen into a single column, eliminating the Psion Teklogix NEO Hand-Held Computer User Manual

129

Page 142

Chapter 5: Configuration User need for horizontal scrolling. Enabling Focus Rectangle adds a yellow rectangle around the cursor to make it clearly visible on the screen. 5.10.2.2 User Display Settings

User Font Size This option allows you to adjust the size of the font used the NEO display: Large, Normal or Small. 5.10.2.3 User System Settings

Docking Port Message Checking this box blocks the message that normally pops up on the display when NEO is docked. 130

Psion Teklogix NEO Hand-Held Computer User Manual

Page 143

Chapter 5: Configuration Registry Editor

5.10.3 Registry Editor

This option is reserved for senior administrators who have a strong understanding of registry keys and values. Careless registry editing can cause irreversible damage to NEO.

5.11

Error Reporting Error Reporting allows you to enable or disable Microsoft error reporting prompts. •

5.12

Tap on Start>Settings>Control Panel. Tap on the Error Reporting icon.

Dr. Debug Dr. Debug is an error diagnostic tool. •

Tap on Start>Settings. Tap on Control Panel followed by the Dr. Debug icon.

Psion Teklogix NEO Hand-Held Computer User Manual

131

Page 144

Chapter 5: Configuration Status

5.12.1 Status

This tab indicates the status (on/off) of the tools. Tapping on Browse logs displays error logs for your review.

5.12.2 Settings

• •

132

Choose an Error Level from the drop down menu. To change the location where debug information will be stored, tap on the button to the right of the Log Folder option.

Psion Teklogix NEO Hand-Held Computer User Manual

Page 145

Chapter 5: Configuration Utilities

5.12.3 Utilities

The Utilities tab is used to log network traffic. When you tap on the Start button, debug data is collected so that, if necessary, it can be forwarded to a Psion Teklogix technician for evaluation.

5.13

Teklogix Imagers Settings The Teklogix Imagers applet is used to create, modify, delete and activate imager settings. The principal uses of the applet are to decode bar codes and to capture images.

Note: This icon is only displayed when the appropriate imager is installed in your handheld computer.

Psion Teklogix NEO Hand-Held Computer User Manual

133

Page 146

Chapter 5: Configuration Imager Demo Applet

•

To launch this applet, tap on Start>Settings>Control Panel, and then tap on the Teklogix Imagers icon.

Important: Refer to Appendix E: “Teklogix Imagers Applet” for details about this applet.

5.13.1 Imager Demo Applet An Imager demo applet is also provided to illustrate how the imager works. •

134

To launch the demo applet, tap on Start>Programs, and then tap on the Imager icon.

Psion Teklogix NEO Hand-Held Computer User Manual

Page 147

Chapter 5: Configuration Teklogix Scanner Settings Scanner Menu

5.14

Teklogix Scanner Settings The Teklogix Scanners icon in the Control Panel provides dialog boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize. The parameters are preset with the default settings of the decoded scanner installed in the unit. Not all options apply to all scanners. For a listing of available scanners and their specifications, please refer to Chapter 7: “Specifications”.

5.14.1 Bar Codes Tab

Note: Refer to Appendix C: “Bar Code Settings” for details about the symbols for each scanner type. 5.14.1.1 Scanner Menu The drop-down menu to the right of the Scanner: option allows you to choose from one of the following scanner types used with your hand-held: Decoded (internal) and Decoded (ISCP). If an HHP 5000 imager is installed in your unit, refer to Appendix D: “Teklogix Imagers Applet” for details about setting up your imager. The symbologies listed change to reflect the scanner you choose and the bar codes it supports.

Psion Teklogix NEO Hand-Held Computer User Manual

135

Page 148

Chapter 5: Configuration Bar Codes Tab

Important: To improve the decode speed and performance, enable only those codes that are required by the application. Keep in mind that some bar code types are only available when an internal imaging scanner is installed. All internal scanners can be configured using the Barcode dialog boxes. 5.14.1.2 Restoring Default Settings Note: The pop-up menu function described in this section is only available on units with the Windows CE Professional operating system. If you want to restore the factory defaults after making changes, the defaults can be applied to a selected parameter, sub-tree of parameters or all scanner parameters. To display a popup menu, you need to press and hold the stylus on a menu item. (This equivalent to a rightclick on a PC.) •

Press and hold the stylus on a symbology (e.g., Code 128) to display a pop-up a menu.

•

Choose Default subtree to reset only the parameters in the symbology you selected, or choose Default all settings to reset all scanner parameters to default settings. To reset a single parameter to its default setting:

136

Psion Teklogix NEO Hand-Held Computer User Manual

Page 149

Chapter 5: Configuration Options Tab

•

Press and hold the stylus on the parameter you want to reset.

•

Choose Default parameter to reset the parameter to the default setting.

5.14.2 Options Tab This tab allows you to tailor the double-click parameters and the display options associated with your scanner.

5.14.2.1 Double Click Parameters Click Time (msec) This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is con-

Psion Teklogix NEO Hand-Held Computer User Manual

137

Page 150

Chapter 5: Configuration Options Tab sidered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature. A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, doubleclicking the scanner trigger inserts the “Click Data” value rather than initiating a scan. Click Data This parameter determines which character is sent to the application installed in NEO following a double-click. A dialog box appears, asking that you press the key you want to insert. The ASCII/Unicode key value of the keypress is displayed. 5.14.2.2 Display Parameters Scan Result When this parameter is enabled, the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen. Scan Indicator When this parameter is enabled, the laser warning logo appears on the display whenever the scanner is activated. Scan Result Time (sec) The value assigned to the “Scan Result Time (sec)” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter. When you choose this option, a dialog box appears where you can enter a value. Note: To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger. Good Scan Beep And Bad Scan Beep These parameters determine whether or not the NEO emits an audible scanner ‘beep’ when a good (successful) scan or a bad (unsuccessful) scan is performed. Set these parameters to either on to enable the beeper or off to disable it.

138

Psion Teklogix NEO Hand-Held Computer User Manual