Page 323

Chapter 6: Tekterm Application Fields

Mixed AIAG When this parameter is enabled (set to “Y”), AIAG labels are always accepted and processed – even if mixed with keyboard input. The AIAG label can replace the partially entered keyboard data. If this parameter is disabled, AIAG labels are rejected if field entry is in progress.

Rjct if Alpha When the cursor is in a numeric field and “Rjct if Alpha” is enabled (set to “Y”), bar codes containing alphabetic characters are rejected.

Beam Lockout When enabled (set to “Y”), this parameter disallows scanner use when the current session is in “LOCK-H” mode.

6.19.2.7 Fields Fields 05 Field Order Y Enter To F0 Y Enter On Arrow Y Video » All Fld Video Y Default Font 17x30 Entry Mode field Open Fky Only N Ign Bcode_fld N Enh Edit Mode N Valid Numerics +-%*/.,$

Range Y/N Y/N Y/N see text Y/N see text see text Y/N Y/N Y/N see text

Field Order This parameter determines the mode of cursor movement between fields. The next field can be defined by location on the screen or by the assignment of field numbers. When enabled (set to “Y”), the cursor moves according to field location. If disabled (set to “N”), the cursor moves according to the numeric order of the fields.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

297

Page 324

Chapter 6: Tekterm Application Fields

Enter To F0 The <ENTER> key normally enters data into a field and moves the cursor to the next field. However, some applications require that the <ENTER> key start a transmission from the 7535/7530. When enabled (set to “Y”), this parameter causes the <ENTER> key to be interpreted as <F0> which starts a transmission.

Enter On Arr When this parameter is enabled (set to “Y”), the arrow keys can be used to complete data entry into a field.

Video 06 Video Blink Bold Reverse

BLNK ULIN REV

Range see text see text see text

Blink The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Blink” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

Bold The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Bold” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

Reverse The value assigned to the “Reverse” parameter specifies the actual video attributes to be assigned to fields created with the “Reverse” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

All Fld Video Usually, the video attributes apply only to the text that is in an entry field. When this parameter is enabled (set to “Y”), the entire field (including blanks) takes on the video attributes. Some systems use this option to identify empty entry fields with reverse video.

298 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 325

Chapter 6: Tekterm Application Fields

Default font This parameter determines the default font that appears when the memory is reset. •

Use the <RIGHT> or <LEFT> arrow key to scroll through the options.

Entry Mode “Entry Mode” parameters allow you to select a data entry mode. The modes are: insert, replace, field and fcursor. “TESS Edit Modes And Cursor Movement” on page 230 describes these modes in detail.

Open Fky Only When this parameter is enabled (set to “Y”), the screen is open for function keys only, and the cursor is not positioned. When this parameter is disabled, the screen is open for data entry, and the cursor is placed in the first field (if it exists).

Ign Bcode_fld When this parameter is enabled (set to “Y”), fields that were defined as “bar code only” accept data from the keyboard as well as the bar code reader. In effect, they behave as data entry fields.

Enh Edit Mode This mode provides extended (enhanced) functions to users of Psion Teklogix’ IBM 5250 terminal emulation. When this parameter is enabled (set to “Y”), the arrow keys move the cursor anywhere on the screen, unrestricted by fixed or entry fields. Certain 5250 emulation keys (e.g. Field Exit) that were originally available only when “Enh Edit Mode” was set to “Y” are now active at all times in TESS applications. Refer to “IBM 5250 Emulation Keys” on page 229 for details about these keys.

Valid Numerics This parameter is used to configure valid characters for numeric fields to a maximum of 39 characters. Since this field is numeric, numbers 0 through 9 do not need to be configured. The default values for this parameter are: + - % / . , $.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

299

Page 326

Chapter 6: Tekterm Application Anchor View

6.19.2.8 Anchor View Anchor 05 x origin y origin

1 1

Range 1..24 1..80

When enabled (set to “Y”), this parameter locks the display at a defined location on the screen, preventing it from shifting when the cursor is moved. The “x origin” and “y origin” coordinates specify where the screen origin, the upper left corner of the screen, will be fixed.

x origin and y origin The “x origin” parameter is used to specify the column to which the upper left corner of the screen will be anchored. The “y origin” parameter is used to specify the row coordinate to which the screen will be anchored.

6.19.2.9 Emulation Note:

These parameters are only accessible when one of the following TESS ‘Host Conn’ options is selected: ‘2392/Telnet’, ‘3274/Telnet’ or ‘5250/Telnet’.

2392/Telnet Emulation 05 Emulation Send CR with Fkey N Features »

Range Y/N see text

Send CR with FKEY A function key press generates a string of text to be sent back to the host. If this parameter is enabled, a carriage return is appended to the function key.

300 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 327

Chapter 6: Tekterm Application Emulation

Features – 2392/Telnet Features 06 Clear Entry Fields N Passthru Printing N AIAG Character 0 Barcode Character 0 Serial IO Character 0 Fixed Field Ovrhd 5 Enable Alarm N Command Region Up 0 Command Region Down 0 Command Region Left 0 Command Region Right0

Range Y/N Y/N 0-255 0-255 0-255 0-80 Y/N 0-24 0-24 0-80 0-80

Clear Entry Fields When this parameter is set to ‘Y’, an empty entry field is created in place of an entry field filled with spaces. Note:

This operation is only performed on screens received from the host. Data sent to the host remains unaffected.

Passthru Printing Setting this parameter to ‘Y’ allows the host to send data directly to the 7535/7530 serial port. This option is most commonly used for printing.

AIAG Character This parameter is used to enter a decimal representation of the ASCII character code of the AIAG character. A value of 0 (zero) disables this feature. When a bar code data is scanned, the 7535/7530 searches for AIAG fields on the current page that can accept the bar code data. The application program distinguishes an entry field as AIAG by preceding the field with this special mode character which indicates the existence of AIAG fields.

Barcode Character Barcode-input-only fields are special entry fields that only accept input from a bar code reader. The application program identifies a barcode-input-only entry field by preceding the field with a special character.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

301

Page 328

Chapter 6: Tekterm Application Emulation This parameter is used to enter a decimal representation of the ASCII character code of the barcode-input-only character. A value of 0 (zero) disables this feature.

Serial IO Character Serial I/O fields are special entry and fixed fields that accept input from and output to a serial port. The application program distinguishes this field as Serial I/O by preceding the field with a special character. If this character precedes a fixed field, the data will be sent to the 7535/7530’s serial port. If it precedes an entry field, the field accepts data from the hand-held’s serial port. This parameter allows you to enter a decimal representation of the ASCII character code of this special character. A value of 0 (zero) disables this feature.

Fixed Field Ovrhd This parameter defines the maximum number of characters allowed within two adjacent, fixed fields that can be sent as a single field. For example, if two fields are 4 characters apart and this parameter is set to 5, these fields are joined into a single field of data. The allowable range for this field is 0 to 80. This feature affects fields with the “Normal” display attribute only.

Enable Alarm If this parameter is set to ‘Y’, the 7535/7530 emits a beep when the word ALARM appears on the application screen, in the location specified by the “Command Region” parameter.

Command Region Up & Down And Command Region Left & Right The value assigned to the ‘Command Region Up’ and ‘Command Region Down’ parameters represent rows on the 7535/7530 screen. The allowable values range from 0 to 24. The value assigned to ‘Command Region Left’ and ‘Command Region Right’ parameters represent columns on the 7535/7530 screen. The allowable values range from 0 to 80. These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region. Currently, the only commands supported in the command region are ALARM and FONT:

302 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 329

Chapter 6: Tekterm Application Emulation

3274/Telnet Emulation Emulation 05 Fujitsu Host Intl EBCDIC Nulls in Fields IP for SysReq BRK for Attn LU Name Enabled LU Name Features FKEY0-7 FKEY8-15 FKEY16-23 FKEY24-31 FKEY32-39

N N N N N N » » » » » »

Range Y/N Y/N Y/N Y/N Y/N Y/N see text see text see text see text see text see text see text

Fujitsu Host If this parameter is set to ‘Y’, data is sent in Fujitsu format. Enabling ‘Fujitsu Host’ causes the standard IBM formatting codes (for start of field, setting buffers, etc.) to be replaced by the codes used by Fujitsu host computers.

Intl EBCDIC If this parameter is enabled (set to ‘Y’), the ‘international’ EBCDIC character set is used, swapping the positions of the ! and ] characters.

Nulls in Fields Setting this parameter to ‘Y’ allows ‘null’ characters – e.g., hyphens (-) or periods (.) – to fill in empty entry fields.

IP for SysReq When the system request key is pressed, a Telnet “Interrupt Process” command is generated. The “Interrupt Process” command is sent to the host in place of the standard mechanism used to send the system request key press to a host using Telnet.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

303

Page 330

Chapter 6: Tekterm Application Emulation

BRK for Attn When the attention key is pressed, a Telnet “Break” command is generated. This command is sent to the host in place of the standard mechanism used to send the attention key press to a host using Telnet.

LU Name Enabled If enabled (set to ‘Y’), this parameter allows the 7535/7530 to negotiate a specific device name for itself.

LU Name The value assigned in this field is used when the “LU Name Enabled” parameter (see above) is set to ‘Y’. The current terminal number is appended to the name to generate a unique device name (for example, LUA00001).

Features – 3274/Telnet Features 06 Clear Entry Fields N Passthru Printing N AIAG Character 0 Barcode Character 0 Serial IO Character 0 Fixed Field Ovrhd 5 Enable Alarm N Command Region Up 0 Command Region Down 0 Command Region Left 0 Command Region Right 0

Range Y/N Y/N 0-255 0-255 0-255 0-80 Y/N 0-24 0-24 0-80 0-80

These parameters are identical to those described for 2392/Telnet. Refer to “Features – 2392/Telnet” beginning on page 301.

304 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 331

Chapter 6: Tekterm Application Emulation

FKEY0-7, FKEY8-15, FKEY16-23, FKEY24-31 And FKEY32-39 06

FKEY0-7

FKEY0 FKEY1 FKEY2 FKEY3 FKEY4 FKEY5 FKEY6 FKEY7

ENTER F1 F2 F3 F4 F5 F6 F7

The sub-menus attached to these parameters allow you to map the 7535/7530 function keys.

5250/Telnet Emulation 05

Emulation

WEC Remap Underline to Intl EBCDIC Nulls in Fields Term Type Virtual Dev Enable Virtual Dev Prefix Features FKEY0-7 FKEY8-15 FKEY16-23 FKEY24-31 FKEY32-39

Range Advisory None N Y IBM-5251-11 N » » » » » » see text see text Y/N Y/N see text Y/N see text see text see text see text see text see text see text

WEC (Write Error Code) This parameter determines the type of WEC used. If set to “advisory”, a TESS advisory message is generated when the host sends a WEC command to the 7535/7530. Otherwise, if set to “screen text”, the hand-held locks the keyboard and displays the error message contained in the WEC command on the screen at the line specified by the host. In this case, the 7535/7530 must be unlocked manually using the function key mapped to RESET.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

305

Page 332

Chapter 6: Tekterm Application Emulation

Remap Underline To This parameter allows you to remap the underline cursor to: blink, bold or reverse.

Intl EBCDIC If this parameter is enabled (set to ‘Y’), the ‘international’ EBCDIC character set is used, swapping the positions of the ! and ] characters.

Nulls In Fields Setting this parameter to ‘Y’ allows ‘null’ characters – e.g., hyphens (-) or periods (.) – to fill in empty entry fields.

Term Type The value assigned for this parameter – IBM-5555-001 or IBM-5251-11 – indicates the type of terminal to report during the Telnet negotiations. It determines how the AS/400 host treats the terminal. IBM-5251-11 is a standard 5250 terminal. IBM-5555-001 is a Korean language terminal.

Virtual Dev Enabled If enabled (set to ‘Y’), this parameter allows the 7535/7530 to negotiate a specific device name for itself.

Virtual Dev Prefix The prefix assigned in this field is used when the “Virtual Dev Enabled” parameter (see above) is set to ‘Y’. The current terminal number is appended to the prefix to generate a unique device name. You can assign up to 10 upper-case alphanumeric characters in this field.

306 Psion Teklogix 7535/7530 Hand-Held Computer User Manual