Page 313
Chapter 6: Tekterm Application Screen
Settings Note:
The “Settings” sub-menu is not available when 802.IQv2 is selected as the “Conn Type” Settings Host Port
9999
Range see text 0-9999
Host This parameter is used to assign a host IP address using the format ###.###.###.###
Port “Port” specifies the port number. By default, the port is assigned the value 9999.
6.19.2.2 Screen 05 Screen # of Cols 80 # of Rows 24 Origin Scroll N Field Scroll N Pages Saved 16 App. Parameter 0 Label F1-4 » Colour Override N»
Range 20..132 4..100 Y/N Y/N 1..16 -1..79 see text see text
# of Cols This parameter defines the logical page width (in characters) used by the host computer application. Emulator systems trim the host application screens to this width. This page width cannot be smaller than the width of the 7535/7530 display. Display panning is used if the page is wider than the display. Note:
The value in this parameter must be an even number.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
287
Page 314
Chapter 6: Tekterm Application Screen
# of Rows This parameter defines the logical page length (in lines) used by the host computer application. Emulator systems trim the host application screens to this length. This page length cannot be smaller than the length of the hand-held computer’s display. Display panning is used if the page is longer than the display. Note:
The value in this parameter must be an even number.
Origin Scroll When enabled (set to “Y”), the display window moves to the origin (upper-left corner) after “LOCK-H” or “LOCK-B” messages.
Field Scroll When enabled (set to “Y”), the display window moves to the left after entering a new entry field.
Pages Saved This parameter determines the number of pages that can be stored and recalled at the 7535/7530. Storing frequently used page data at the 7535/7530 reduces the need for the host to retransmit complete page data over the radio link. Retransmitting data can reduce the system response time. Increasing the number of saved pages decreases the available memory for other functions.
App. Parameter The “Application” parameter is sent to the host system as part of the response to the TESS query command. Enter zero to disable this parameter.
Label F1-F4 Note:
This menu uses string entry fields. For detailed information about completing this type of field, refer to “String Entry Parameters” on page 245. 06 F1 F2 F3 F4
Label F1-4
288 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 315
Chapter 6: Tekterm Application Characters Softkeys are function keys that have been programmed to perform specific actions in your application. These keys are identified through softkey labels – reverse video labels that are displayed at the bottom of the screen. These softkey labels can be reconfigured using the menu attached to the “Label F1-F4” parameter. To edit a label: •
Note:
Position the cursor in the appropriate function key field within the Label menu, and type a new name – preferably one that describes the corresponding key’s function. Although you can enter up to 8 characters for each softkey label, the text will be shortened to better fit in the available space on your display.
Colour Override Note:
If you have a 7535 with a monochrome display, this menu is not available. Range 06 Colour Override Foreground Background
Black White see text see text
Foreground And Background When “Colour Override” is set to ‘Y’, the colours chosen in this menu are displayed in the TESS sessions. These colour settings override the “Default Colours” set from within the “View Manager” menu. Refer to “Default Colours” on page 266 for details. The allowable values are: Red, Green, Yellow, Blue, Magenta, Cyan, White and Black.
6.19.2.3 Characters 05 Characters Char Set » V Match Char 0 H Match Char 0 Fill Chr 46 Upper Case N
Range see text 0..255 0..255 0..255 Y/N
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
289
Page 316
Chapter 6: Tekterm Application Characters
Char Set 06 Char Set ISO N » IBM Y » DEC N » Misc. N » This menu contains all the character sets available with your Psion Teklogix computer. In this menu, the “Y” or “N” is used to visually guide you to the selected character set. For example, in the sample menu above, the “Y” next to IBM indicates that a character set has been chosen from this group. To choose a character set: •
Position the cursor on the appropriate item – for example, ISO – and press <F1> to display the character set options.
•
To activate a character set, press the <RIGHT> or <LEFT> arrow key to set it to “Y”.
Important:
If you choose a Chinese character set from the ‘Misc.’ menu and a character sent from the host cannot be displayed on the 7535/7530 screen, a shaded box character is used as a substitute. Please review “Default font” on page 299. If you are using a Korean character set, a right arrow character is used as a substitute.
V Match Chr This parameter enables visible field matching and defines the character that identifies visible field match data from the host. Field matching allows the host to pre-load data into an entry field that is compared with the user’s input. The hand-held beeps if the entered data does not match. Visible field matching means that the data to be matched is displayed in the entry field. Enter the decimal value for the ASCII character that will be used by the host to identify visible match field data. Enter 0 (zero) to disable this feature. Note:
Another method of field matching is available directly through the TESS data stream.
290 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 317
Chapter 6: Tekterm Application Tests
H Match Chr This parameter enables hidden field matching and defines the character that identifies hidden field match data from the host. Field matching allows the host to pre-load data into an entry field that is compared with the user’s input. The 7535/7530 beeps if the entered data does not match. Hidden field matching means that the data to be matched is not displayed in the entry field. Enter the decimal value for the ASCII character that will be used by the host to identify hidden match field data. Enter 0 (zero) to disable this feature. Note:
Another method of field matching is available directly through the TESS data stream.
Fill Chr This parameter specifies the character that identifies empty entry fields. Enter the ASCII decimal equivalent of this character. The most commonly used characters are: _ (underline) . (period) Note:
Enter 95 Enter 46
7535/7530s in some systems may use the “space” character with the host using reverse video attributes to mark entry fields.
Upper Case When this parameter is enabled (set to “Y”), lowercase input is converted to uppercase.
6.19.2.4 Tests 05 Tests AutoRep Fn AutoRep T/O
7 5
Range 0..63 0..255
AutoRep Fn This parameter determines which function key is sent to the host in auto reply mode. The value represents the number of the function key – not the ASCII decimal equivalent. After sending this key, the unit locks and waits for the host to unlock the 7535/7530. To disable “AutoRep Fn”, set the “AutoRep T/O” parameter to zero. Psion Teklogix 7535/7530 Hand-Held Computer User Manual
291
Page 318
Chapter 6: Tekterm Application Features
AutoRep T/O This parameter determines the time (in seconds) between the 7535/7530 unlocking and the next transmission of the function key specified by the above parameter. A value of zero disables auto reply mode.
6.19.2.5 Features 05 Features Printer Binary print Queuing Lcl Process Send Mile Next X Kbd Locked Remap Passthru Disable Beep Serial
Y N Y Y» N N N N N »
Range Y/N Y/N Y/N see text Y/N Y/N Y/N Y/N Y/N see text
Printer This parameter enables and disables the pins in the serial port used for printers or other external devices.
Binary print When this parameter is enabled (set to “Y”), the page displayed on the 7535/7530 computer is spooled as is, except for trailing white-space removal. When disabled (set to “N”), each line of the page displayed on the hand-held is preceded by a linefeed (LF) and followed by a carriage return (CR).
Queuing This parameter enables and disables queuing mode (see “Queuing Mode” on page 236). It also enables TESS procedures to be loaded into the 7535/7530. This parameter should be enabled if local procedures and the ability to switch between hosts within a TESS session are required. Changes to this parameter take effect only after the 7535/7530 is reset.
292 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 319
Chapter 6: Tekterm Application Features
Lcl Process – Save on Reset The menu item “Local Process” has a sub-menu attached to it – “Save on Reset”. When this parameter is enabled (set to “Y”), data stored in the 7535/7530 is saved if the unit is reset. Local procedures are defined on page 235.
Send Mile This parameter controls the sending of a milestone from the 7535/7530 after a “hey_you” command. Consult the Teklogix Screen Subsystem (TESS) User Manual for more information on milestones.
Next X This parameter enables and disables the next messages used in queuing mode.
Kbd Locked This parameter allows you to lock (set to “Y”) or unlock (set to “N”) the keyboard for all alphanumeric input in TESS. When the keyboard is locked, the function keys, arrow keys and the <ENTER> key are still functional. The 7535/7530 emits an error beep if a character is rejected because the keyboard is locked. Changes to this parameter take effect only after the unit is reset.
Remap Passthru When this parameter is set to “Y”, passthru data is remapped from the host charset to the port charset. (Normally passthru data is sent as is to the port without any remapping.)
Disable Beep Setting this parameter to “Y” disables the beep generated by the ‘o’, ‘G’ and ‘#’ TESS commands. Keep in mind that Error and Scan beeps are not disabled.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
293
Page 320
Chapter 6: Tekterm Application Features
Serial 06 Serial Serial Port Serial Out Serial In SI mode SI prefix SI suffix SI CRC SI Fkey SO prefix SO suffix SO CRC
Any Available Y N 10 13 N 0 10 13 N
Range see text Y/N Y/N see text 0..255 0..255 Y/N 0..255 0..255 0..255 Y/N
Serial Port TESS print commands control the transfer of data to and from the serial and printer ports on the 7535/7530. At the 7535/7530 computer, the value assigned at the ‘Serial Port’ parameter ranks which port the TESS print command will identify and use as the first to fourth port. The allowable options are: Any Available, 1st Serial, 2nd Serial, 3rd Serial, 4th Serial and Disabled.
Serial Out This parameter enables serial port output fields.
Serial In This parameter enables the serial port input fields. If enabled (set to “Y”), the TESS application has exclusive use of the serial port. Acceptance of data in a SI field is determined by the SI prefix and suffix.
SI mode The possible values for this parameter are field (the default) and command. When the SI mode is set to field, data received through the serial port is displayed in the serial input fields. If you are using serial-input fields, make sure the “SI mode” parameter is set to field. When “SI mode” is set to command, data received by the serial port is transmitted as Passthrough data to the host. Note:
“Command” mode is supported by SDKs but not by emulations.
294 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 321
Chapter 6: Tekterm Application Features
SI prefix This parameter determines the start-of-message character on serial input. Enter an ASCII numeric equivalent from 0 to 255 to represent the start character. A value of 0 (zero) indicates no prefix.
SI suffix This parameter determines the end-of-message character on serial input. Enter an ASCII numeric equivalent from 0 to 255 to represent the end character. A value of 0 (zero) indicates no suffix.
SI CRC This parameter enables or disables CRC validity check on serial input. When enabled (set to “Y”), a packet is rejected if the CRC is not valid. Also, when this parameter is enabled (set to “Y”), each time a DLE (^P=0x10) character is encountered in the serial input, it is removed and the character following it will be replaced with its 1’s complement.
SI Fkey This parameter allows you to choose the function key you want appended to the serial input. For example, entering a value of “1” appends <F1> to serial input. A value of “0” (zero) disables this parameter; a suffix is not added. Note:
Data is transmitted as soon as the function key has been appended.
SO prefix This parameter determines the start-of-message character on serial output. Enter an ASCII numeric equivalent from 0 to 255 to represent the start character. A value of “0” (zero) indicates no prefix.
SO suffix This parameter determines the end-of-message character on serial output. Enter an ASCII numeric equivalent from 0 to 255 to represent the end character. A value of “0” (zero) indicates no suffix.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
295
Page 322
Chapter 6: Tekterm Application Scanner
SO CRC When this parameter is enabled (set to “Y”), a CRC16 value is appended to the serial output message. Also, when this parameter is enabled (set to “Y”), for each control character in the serial output stream, a DLE is inserted to precede that character. The control character is replaced with its 1’s complement.
6.19.2.6 Scanner 05 Scanner Cont Nxt Fld Append Enter Append F0 Mixed AIAG Rjct if Alpha Beam Lockout
Y Y Y N N N
Range Y/N Y/N Y/N Y/N Y/N Y/N
Cont Nxt Fld This parameter only applies to string entry data. When enabled (set to “Y”), this parameter allows bar codes that are longer than the field length to continue in the next field. If “ContNxtField” is disabled (set to “N”), OFF data will flow into the next field.
Append Enter When enabled (set to “Y”), “Append Enter” causes an <ENTER> code to be appended to the bar code. The <ENTER> code completes the entry of the bar code and moves the cursor to the next field.
Append F0 When enabled (set to “Y”), this parameter causes an <F0> code to be appended to the bar code. The <F0> code completes the entry of the bar code data in the field.
296 Psion Teklogix 7535/7530 Hand-Held Computer User Manual