The text of a manual · part 33 of 48
7535/7530 Hand-Held Computer User Manual: Tekterm Application 6, pages 303 to 312
Pages 303 to 312 of 440, from 7535/7530 Hand-Held Computer User Manual
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7530 and Teklogix 7535
Page 303
Chapter 6: Tekterm Application Xmit Modes
Xmit Wait This parameter determines the length of time the 7535/7530 collects keystrokes before transmitting them to the host. This value is specified in increments of one 10th of a second (i.e., a value of 10 represents 1 second). If 0 (zero) is selected, the computer transmits only according to the “Xmit Count” parameter. Note:
If the 7535/7530 is not in local edit mode, the <ENTER>, arrow, <CTRL>, and function keys cause an immediate radio transmission regardless of the “Xmit Wait” parameter setting.
Dev Attr This string entry parameter specifies a device attribute string. This string can be up to 16 characters long. The computer sends this string to the host when it receives a DA or DECID control. The example shown in the “Xmit Modes” screen sample on page 276 is the device attribute sent to a VAX, identifying the Psion Teklogix hand-held computer as a VT220 terminal. This parameter may or may not be set, depending on the requirements of the host computer.
Auto-Answer This string can be up to 30 characters long and is sent by the 7535/7530 as a reply to an “ENQ” character from the host. The “Auto-Answer” string is programmable in the same manner as the keyboard macros. For example, this string can be used to automatically send the username and password when logging into the host. Refer to “Macro Control Panel” beginning on page 255 for additional details about macros.
7 bit When this parameter is disabled (set to “N”), the hand-held computer transmits 8 bit controls. When enabled (set to “Y”), the hand-held transmits 7 bit controls. This parameter applies to character mode, block mode, and media copy mode.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
277
Page 304
Chapter 6: Tekterm Application Xmit Modes
Block Mode 06 Block Mode Kbd lock Xmit key FETM GATM MATM SATM TTM EOL chars EOB chars
N N N N N Y Y
All modes in this section affect the data stream sent to the host computer, the serial port and the console port. These modes apply to the Block mode (Local Editing) and the Media Copy function, unless otherwise noted. Consult the Teklogix ANSI Terminal Programmer’s Manual for more information.
Kbd lock When this parameter is disabled (set to “N”), the 7535/7530 does not lock the keyboard after a block mode transmission. When enabled (set to “Y”), the keyboard is locked after a transmission. The application program must unlock the keyboard by resetting the Keyboard Action Mode (KAM), using the Reset Mode (RM) or Enable Manual Input (EMI) controls.
Xmit key When this parameter is disabled (set to “N”), the key that causes the hand-held to transmit is not sent to the host as part of the transmitted data. When enabled (set to “Y”), the key that causes a transmission is sent after the page data has been sent to the host. This parameter applies only to block mode.
FETM When the Format Effector Transfer Mode (FETM) parameter is disabled (set to “N”), Format Effectors are inserted in data sent to the host or included in data when transferred to the console or serial ports. When enabled (set to “Y”), the Format Effectors are not inserted into the data sent to the host and are not included in the data transferred to the console or serial ports.
278 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 305
Chapter 6: Tekterm Application Xmit Modes
GATM When the Guarded Area Transfer Mode (GATM) parameter is disabled (set to “N”), only unguarded data is transmitted to the host or transferred to the console or serial ports. When enabled (set to “Y”), both guarded and unguarded data can be transmitted to the host or transferred to the console or serial ports.
MATM When the Multiple Area Transfer Mode (MATM) parameter is disabled (set to “N”), only the selected area containing the cursor can be transmitted to the host or transferred to the console or serial ports. When enabled (set to “Y”), all selected areas can be transmitted to the host or transferred to the console or serial ports. This mode is significant only if the Selected Area Transfer Mode (SATM) is disabled.
SATM When the Selected Area Transfer Mode (SATM) parameter is disabled (set to “N”), the selected areas defined by SSA/ESA and DAQ can be transmitted to the host or transferred to the console or serial ports. When enabled (set to “Y”), the full contents of the buffer can be transmitted to the host or transferred to the console or serial ports.
TTM When the Transfer Termination Mode (TTM) parameter is disabled (set to “N”), the cursor position determines the end of the string that can be transmitted to the host or transferred to the console or serial ports. When enabled (set to “Y”), the cursor position is ignored.
EOL chars This string entry parameter specifies a string of up to 8 characters that are sent after each line in a block transmission. If the parameter is not used, the rules specified in “Transmitted Data Stream” are used to determine end of line characters.
EOB chars This string entry parameter specifies a string of up to 8 characters that are sent after each block transmission.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
279
Page 306
Chapter 6: Tekterm Application Kbd Modes
6.19.1.4 Kbd Modes 05 Kbd Modes Arrow mode Echo mode DEL key BKSP key PrintScreen key Xmit Enter Insert Newline Disable kbd DEC Cursor Keys cursor Smart DEL BS 16 Y N N N cursor mode
Range cursor, field Smart, Local, Host DEL, BS, Clear BS, Clear, DEL 1..255 Y/N Y/N Y/N Y/N see text
Arrow mode This parameter determines whether arrow keys move the cursor within a field or between fields. When set to “field”, pressing an arrow key causes the cursor to move to the next field in the direction of the arrow. When set to “cursor”, pressing the <LEFT> and <RIGHT> arrow keys move the cursor within the current field.
Echo Mode This parameter selects echo mode for the 7535/7530. The available modes are “Local”, “Host”, and “Smart”. Local:
In this mode, any character entered using the keyboard is displayed before being sent to the host. Certain keys cause additional action at the 7535/7530, as shown in Table 6.4 on page 281.
Host:
In this mode, the hand-held computer sends all keyboard entries to the host and displays only data received from the host.
Smart: This mode reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host computer. The 7535/7530 displays all printable characters on the screen before sending them to the host. The hand-held compares the characters echoed by the host to the characters placed on the page and fixes the display if the host echoes are different. The maximum number of characters waiting for echo is 25. Any additional characters are sent to the host but not displayed. When the 7535/7530 is in insert mode, smart echo is disabled. 280 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 307
Chapter 6: Tekterm Application Kbd Modes
Key
Function
ENTER
In newline mode, this key moves the cursor to the first column of the next line. In line feed mode, this key moves the cursor to column one of the current line.
CTRL-G (Bell)
The 7535/7530 beeps.
CTRL-H (Backspace)
The cursor moves back one space.
CTRL-I (Tab)
The cursor moves to the next horizontal tab stop.
CTRL-J (Line Feed) CTRL-L (Form Feed) CTRL-K (Vertical Tab) DEL
The cursor moves down one line in the same column. The cursor moves down to the next line with a vertical tab set. This key deletes the character to the left of the cursor and moves the cursor to the left by one position.
Table 6.4 Function Of Special Keys In Local Echo Mode
DEL Key This parameter determines whether the <DEL> key acts as a delete key, erasing the character to the right of the cursor, a backspace key, erasing the character to the left of the cursor or a <CLEAR> key, erasing the entire contents of the field.
BKSP Key This parameter determines whether the <BKSP> key acts as a delete key, erasing the character to the right of the cursor, or a backspace key, erasing the character to the left of the cursor or a <CLEAR> key, erasing the entire contents of the field.
PrintScreen Key This parameter determines the “hot-key” for printing the screen contents via the 7535/7530 serial port. The default is <CTRL> P (16). Note:
The 7535/7530 port must be set to “printer” (see“Ports, Tether And Console” on page 308).
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
281
Page 308
Chapter 6: Tekterm Application Kbd Modes
Xmit Enter The <ENTER> key normally enters data into a field and moves the cursor to the next field. However, some applications require that the <ENTER> key start a transmission from the 7535/7530. When enabled (set to “Y”), this parameter causes the <ENTER> key to start a transmission.
Insert When this parameter is disabled (set to “N”), it behaves in “replace” mode – a character entered at the keyboard or received from the host replaces the character at the cursor position. The cursor then advances one character position. When enabled (set to “Y”), the character entered at the keyboard or received from the host is inserted at the cursor position after shifting the characters at and following the cursor forward one position. The cursor is advanced one position. The extent of the characters affected by the shift depends on the setting of the “Edit Extent” parameter (see page 283).
Newline When this parameter is disabled (set to “N”), an LF character received from the host causes the cursor to move down one line in the same column. In addition, the <ENTER> key transmits a CR. When enabled (set to “Y”), an LF character received from the host causes the cursor to move to the first column of the next line. The <ENTER> key transmits both a CR and an LF.
Disable kbd Setting this parameter to “Y” disables the keyboard and scanner. When this parameter is set to “N”, the keyboard and scanner are enabled.
DEC Cursor Keys This parameter can be set to either Cursor Mode or Application Mode. Cursor Mode causes the cursor keys to generate ANSI cursor control sequences. Application Mode causes the cursor keys to send application control functions.
282 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 309
Chapter 6: Tekterm Application Edit Modes
6.19.1.5 Edit Modes 04 Edit Modes Auto wrap Erasure mode Tab stop mode Edit extent Disp controls
N N N Line N
Range Y/N Y/N Y/N see text Y/N
Auto wrap If “Auto wrap” is disabled (set to “N”), characters received when the cursor is at the right edge of the screen replace the previously displayed characters. If “Auto wrap” is enabled (set to “Y”), the cursor wraps to the next line when the current line is filled. The display scrolls up if the cursor is at the bottom margin.
Erasure mode When this parameter is disabled (set to “N”), erase functions can only erase unprotected characters. When enabled (set to “Y”), the erase functions can erase characters regardless of their protected state.
Tab stop mode When this parameter is disabled (set to “N”), the setting and clearing of horizontal tab stops apply to the same horizontal position of all lines on the page. When enabled (set to ‘Y”), horizontal tab setting and clearing apply only to the current line.
Edit extent This parameter selects the extent of the display to be affected by the ICH and DCH controls and received character insertion. The possible values are Line, Area, Display or Fld. The shifting caused by ICH, DCH and character insertion is confined to the selected extent.
Disp controls When this parameter is disabled (set to “N”), any control codes received from the host are performed as described. When enabled (set to “Y”), any received control functions are displayed and are not performed. If any C0 or C1 controls are received from the host, their standard ANSI mnemonics are displayed in reverse video. Other characters are displayed as normal characters. This mode can also be set with the Set Mode (SM) control but can only be reset from the Parameters menu.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
283
Page 310
Chapter 6: Tekterm Application Serial
6.19.1.6 Serial 05 Serial Primary Port Secondary Port Async In Start End
Any Available Any Available N 0 0
Range see text see text Y/N 0..255 0..255
Primary Port & Secondary Port ANSI print commands (such as ‘MC’ or Media Copy) control the transfer of data to and from the serial and console ports on the hand-held. At the 7535/7530, the value assigned at the ‘Primary Port’ and ‘Secondary Port’ parameters determines which port the ANSI print command will identify and use as primary and secondary. The allowable options are: Any Available, Ist printer, 2nd printer, 3rd printer, 4th printer, 1st Serial, 2nd Serial, 3rd Serial, 4th Serial and Disabled.
Async In When this parameter is enabled (set to “Y”), the serial (async) port is ready to receive input at all times.
Start/End These parameters specify the “start” and “end” characters of input received from the serial (async) port.
6.19.1.7 Host Char Set The ‘Host Char Set’ menu allows you to specify a character set in the ‘Lower’ and ‘Upper’ character tables. 05 Host Char Set Lower ASCII ISO-IR 006 Upper DEC Multinational Note:
When an 8-bit set is selected from the ‘Lower’ character set, the ‘Upper’ character set will change to the same value. The ‘Upper’ character set cannot be altered until a non-8-bit value is assigned for the ‘Lower’ character set.
To choose ‘Lower’ and ‘Upper’ character sets: • Position the cursor on the ‘Lower’ or ‘Upper’ parameter, and press the <RIGHT> or <LEFT> arrow key to display the character set options. 284 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 311
Chapter 6: Tekterm Application Anchor View •
Press <F4> to save your selection to memory.
Important:
When a character sent from the host cannot be displayed, a rectangular box is used as a substitute.
6.19.1.8 Anchor View 05 Anchor x origin 1 y origin 1
Range 1..24 1..80
When enabled (set to “Y”), this parameter locks the display at a defined location on the screen, preventing it from shifting when the cursor is moved. The “x origin” and “y origin” coordinates specify where the screen origin, the upper left corner of the screen, will be fixed.
x origin and y origin The “x origin” parameter is used to specify the column to which the upper left corner of the screen will be anchored. The “y origin” parameter is used to specify the row coordinate to which the screen will be anchored.
6.19.2 TESS Settings TESS 04 Auto Term # Terminal # Host Conn Screen Characters Tests Features Scanner Fields Anchor View Emulation
N» 1 » » » » » » » N» »
Range see text see text see text see text see text see text see text see text see text see text see text
Each session you create has its own “Settings” parameters. Additional TESS information is documented in “TESS Emulation” on page 227.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
285
Page 312
Chapter 6: Tekterm Application Host Conn.
Auto Term# Note:
“Auto Term#” is available when 802.IQv2 is assigned to the “Host Conn” parameter (page 286) or when 802.IQv1 is enabled in the Radio Menu (see “802.IQ v1” on page 253).
When this parameter is set to “Y”, a unique unit number is assigned for the current TESS session. If “Auto Term#” is set to “Y”, any value assigned to the “Terminal #” parameter is ignored.
Group Auto Term# Group
1
Range 1-5
When “Auto Term#” is set to “Y”, the ‘Group’ parameter is used to identify the group or pool of numbers from which an auto-address is chosen.
Terminal # For every application session you create, the “Terminal #” assigned must be non-zero and unique. This parameter defines the terminal number for the TESS session and uniquely identifies all transmissions to and from the 7535/7530. Other applications running in the 7535/7530, such as an ANSI session or another TESS session must each have a different number. In addition, each Psion Teklogix 7535/7530 using the radio link must have a unique number.
6.19.2.1 Host Conn. Host Conn Conn Type 802.IQv2 Settings »
Range see text see text
Conn Type The options for this a parameter vary depending on the type of application you are running – ANSI or TESS. For TESS applications, this parameter allows you to choose one of the following types of connections: 802.IQv2, 9010t (TCP Direct), 2392/Telnet, 3274/Telnet and 5250/Telnet.
286 Psion Teklogix 7535/7530 Hand-Held Computer User Manual