Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 32 of 48

7535/7530 Hand-Held Computer User Manual: Tekterm Application 6, pages 293 to 302

Pages 293 to 302 of 440, from 7535/7530 Hand-Held Computer User Manual

The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7530 and Teklogix 7535

Page 293

Chapter 6: Tekterm Application Applications

6.19 Applications “TESS” and “ANSI” applications require unique names so that several different sessions of “TESS” and “ANSI” can operate simultaneously. 7535/7530s can support up to 8 sessions at one time. 03 Applications Type1 #1 ANSI Title1 #1 parts Settings 1 » . . . Type1 #8 None Title1 #8 Settings 8 » Important:

Range None, ANSI,TESS see text see text

These applications will become active only after the changes made in the Application screen are saved by pressing <F4> – the SAVE key.

Type And Title Up to eight applications can be entered in this parameter. The “Type #” field indicates the type of session you will be running. The “Title #” parameter should be completed with a name that is meaningful to the operator. •

The available options for the “Type #” field are TESS, ANSI and None. Use the <RIGHT> or <LEFT> arrow key to scroll through the options.

•

The “Title #” field needs a name that is meaningful to the operator. In addition, “TESS” and “ANSI” applications require unique titles so that several different sessions of “TESS” and “ANSI” can operate simultaneously. These titles will appear in startup “Display Menu”. Each session will have its own set of parameters.

•

To display the “Settings” menu for your application, position the cursor on “Settings”, and press <F1> – the NEXT key.

Note:

Before you can access the “Settings” menu, you must first complete the “Name” and “Type” fields. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

267

Page 294

Chapter 6: Tekterm Application ANSI Settings

6.19.1 ANSI Settings Ansi 04 Auto Term # N» Terminal # 1 Host Conn » Screen » Xmit Modes » Kbd Modes » Edit Modes » Serial » Host Char Set » Anchor View N»

Range see text 1..1024 see text see text see text see text see text see text see text see text

Each session you create has its own “Settings” parameters. Additional ANSI information is documented in “ANSI Emulation” on page 236.

Auto Term# Note:

Refer to “Group” on page 268 for additional instructions.

When this parameter is set to “Y”, a unique number is assigned for the current ANSI session. If “Auto Term#” is set to “Y”, any value assigned to the “Terminal #” parameter is ignored. Note:

“Auto Term#” is available when 802.IQv2 is assigned to the “Host Conn” parameter or when 802.IQv1 is enabled in the Radio Menu (see “802.IQ v1” on page 253).

Group Auto Term# Group 1

Range 1-5

When “Auto Term#” is set to “Y”, the ‘Group’ parameter is used to identify the group or pool of numbers from which an auto-address is chosen.

Terminal # For every application session you create, the “Terminal #” assigned must be non-zero and unique. This parameter defines the number for the ANSI session and uniquely identifies all transmissions to and from the 7535/7530.

268 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 295

Chapter 6: Tekterm Application Host Conn Other applications running in the 7535/7530, such as a TESS session or another ANSI session must each have a different number. In addition, each Psion Teklogix 7535/7530 using the radio link must have a unique number.

6.19.1.1 Host Conn Host Conn Conn Type Telnet Settings »

Range 802.IQv2, 9010t, Telnet see text

Conn Type The options for this a parameter vary depending on the type of application you are running – ANSI or TESS and the type of radio installed in your hand-held. For ANSI applications, this parameter allows you to choose one of the following types of connections: 802.IQv2, 9010t (TCP Direct) or Telnet. Keep in mind that choosing Telnet allows the hand-held to communicate directly with the host.

Settings Note:

The “Settings” sub-menu is not available when 802.IQv2 is selected as the “Conn Type”. In addition, this sub-menu varies depending on which option you’ve selected – Telnet or 9010t. Telnet Settings

Host Port 23 Terminal Type VT220 Enter Prompt Press ENTER to connect ESC Prompt Press ESC to cancel Auto Login N» Func Key Remap N» Arrow Key Remap N»

Host Port

Range see text 0-32767 see text see text see text Y/N Y/N Y/N

9010t Settings

Range

9999 see text 0-9999

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

269

Page 296

Chapter 6: Tekterm Application Host Conn

Host This parameter is used to assign a host IP address using the format ###.###.###.### or a host name if DNS is used.

Port “Port” specifies the 9010t (TCP Direct) or Telnet port number. The default 9010t port number assigned is 9999, the maximum allowable value. The default Telnet port number assigned is 23 with a maximum allowable value of 32767.

Terminal Type “Terminal Type” is used to inform the server of the type of terminal the hand-held is emulating. This information is used by the server alone and has no affect on the 7535/7530.

ENTER Pmpt This string indicates that the hand-held is waiting for the user to press <ENTER> at the time of connection.

ESC Prompt This string indicates that the user can press the <ESC> key to terminate a connection attempt before the connection is established.

Auto Login Auto Login Login Prompt Login Password Prompt Password Password Echo Login Failed

Range gin: see text see text word: see text see text Y Y/N incorrect see text

The “Auto Login” parameters are used to define whether or not the hand-held will attempt to log in automatically. The Auto Login sequence is as follows: 1. Host sends “Login Prompt”. 2. Hand-held responds with “Login”. 3. Host sends “Password Prompt”. 270 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 297

Chapter 6: Tekterm Application Host Conn 4. Hand-held responds with “Password”. 5. Host may send password echo. 6. Hand-held ignores password echo if “Password Echo” is set to “Y”, otherwise skip to step 7. 7. Hand-held looks for “Login Failed” in next transmission from host. 8. Login successful or Login failed and return to step 1.

Login Prompt When the hand-held receives the string assigned to this parameter, it will respond with “Login”.

Login The hand-held responds with this string when it receives a “Login Prompt”.

Password Prompt When the hand-held receives this string, it responds with a “Password”.

Password The hand-held responds with this string when it receives a “Password Prompt”.

Password Echo When this parameter is set to “Y”, the host will echo data back to the hand-held after receiving a “Password”.

Login Failed When the hand-held unit receives this string, it assumes that the login attempt has failed and returns to the “Enter Pmpt”.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

271

Page 298

Chapter 6: Tekterm Application Host Conn

Func Key Remap Setting this parameter to “Y” enables the hand-held to use remapped function keys. Each function key has a default string associated with it. When a function key is pressed, the corresponding default string is sent to the host. The ‘Func Key Remap’ table allows these function key character sequences to be redefined. 07 Func Key Remap F 1 1B 4F 50 00 00 00 00 F 2 1B 4F 51 00 00 00 00 F 3 1B 4F 52 00 00 00 00 . . . F28 1B 5B 34 32 7E 00 00 F29 1B 5B 34 33 7E 00 00 F30 1B 5B 34 34 To change values: •

Highlight the function key you want to remap.

•

Either type new values, or press the <LEFT> or <RIGHT> arrow key to change the values.

•

Use the stylus, or press the <TAB> key to move through the string of values.

Arrow Key Remap Setting this parameter to “Y” allows the hand-held to use remapped arrow key strings. Each arrow key has a default string associated with it. When an arrow key is pressed, the corresponding default string is sent to the host. The ‘Arrow Key Remap’ table allows these arrow key character sequences to be redefined. 07 Arrow Key Remap Up Arrow 1B 5B 41 Down Arrow 1B 5B 41 Right Arrow 1B 5B 41 Left Arrow 1B 5B 41

00 00 00 00

272 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

00 00 00 00

Page 299

Chapter 6: Tekterm Application Screen To change values: •

Highlight the arrow key you want to remap.

•

Either type new values, or press the <LEFT> or <RIGHT> arrow key to change the values.

•

Use the stylus, or press the <TAB> key to move through the string of values.

6.19.1.2 Screen Screen 05 # of Pages 4 # of Rows 24 # of Cols 80 Default Font 17x30 80-col. Font 17x30 132-col. Font 17x30 Video » Label F1-F4 » Colour overrideN»

Range 0..16 4..60 80 or 132 see text see text see text see text see text see text

# of Pages This parameter defines how many pages are accessible to application programs. The ANSI control functions – Next Page (NP) and Previous page (PP) – are used to select another page. These pages are independent of each other so that if lines of text scroll off a page, the other pages are unaffected. There is no error indication from the hand-held computer if the memory required by the selected number and size of pages exceeds the memory available in the computer.

# of Rows This parameter defines the logical page length (in lines) used by the host computer application. Emulator systems trim the host application screens to this length. This page length cannot be smaller than the length of the hand-held’s display. Display panning is used if the page is longer than the display. Note:

The value in this parameter must be an even number.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

273

Page 300

Chapter 6: Tekterm Application Screen

# of Cols This parameter defines the logical page width (in characters) used by the host computer application. Emulator systems trim the host application screens to this width. This page width cannot be smaller than the width of the display. Display panning is used if the page is wider than the display. Note:

The value in this parameter must be an even number.

Default font This parameter determines the default font that appears when the 7535/7530 memory is reset. •

Use the <RIGHT> or <LEFT> arrow key to scroll through the available options.

80-col. font & 132-col. font These parameters are used to set the font size on the screen if the default font is not acceptable. An escape sequence must be sent from the host before a hand-held can switch to either 80-col. font or 132-col. font. •

Use the <RIGHT> or <LEFT> arrow keys to scroll through the size options for these parameters.

Video 06 Video Bold Blink Reverse Underline

NONE BLNK REV ULIN

Range see text see text see text see text

The possible attributes for these parameters are: “BLNK” (blink), “ULIN” (underline), “REV” (reverse), and “NONE” (normal).

Bold This parameter specifies the actual video attributes to be assigned to fields created with the “Bold” ANSI attribute.

274 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 301

Chapter 6: Tekterm Application Screen

Blink This parameter specifies the actual video attributes to be assigned to fields created with the “Blink” ANSI attribute.

Reverse This parameter specifies the actual video attributes to be assigned to fields created with the “Reverse” ANSI attribute.

Underline This parameter specifies the actual video attributes to be assigned to fields created with the “Underline” ANSI attribute.

Label F1-F4 Note:

This menu uses string entry fields. For detailed information about completing this type of field, refer to “String Entry Parameters” on page 245. Label F1-4 06 F1 • • • F4

Softkeys are function keys that have been programmed to perform specific actions in your application. These keys are identified through softkey labels – reverse video labels that are displayed at the bottom of the screen. These softkey labels can be reconfigured using the menu attached to the “Label F1-F4” parameter. To edit a label: •

Note:

Position the cursor in the appropriate function key field within the Label menu, and type a new name – preferably one that describes the corresponding key’s function. Although you can enter up to 9 characters for each softkey label, the text will be shortened to better fit in the available space on your display.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

275

Page 302

Chapter 6: Tekterm Application Xmit Modes

Colour Override Note:

If you are using a 7535 equipped with a monochrome display, this menu is not available. Range 06 Colour Override Foreground Background

Black White see text see text

Foreground And Background When “Colour Override” is set to ‘Y’, the colours chosen in this menu are displayed in the ANSI sessions. These colour settings will override the “Default Colours” set from within the “View Manager” menu. Refer to “Default Colours” on page 266 for details. The allowable values are: Red, Green, Yellow, Blue, Magenta, Cyan, White and Black.

6.19.1.3 Xmit Modes 05 Xmit Modes Xmit Count Xmit Wait Dev Attr Auto-Answer 7 bit Block Mode

99 1 [ ? 62 ; 1 ; 2 ; 6 c Y »

Range 0..99 0..999 see text see text Y/N see text

Xmit Count This parameter determines how many characters from the keyboard or scanner are buffered by the 7535/7530 before being transmitted to the host. If 0 (zero) is selected, the hand-held transmits only according to the “Xmit Wait” parameter. If the ANSI block mode features are used, this parameter should be set to 99. Note:

If the 7535/7530 is not in local edit mode, the <ENTER>, arrow, <CTRL>, and function keys cause an immediate radio transmission regardless of the “Xmit Count” parameter setting.

276 Psion Teklogix 7535/7530 Hand-Held Computer User Manual