Chapter 6: Tekterm Application Audio

6.16.2 Audio 04 Audio Normal /windows/default/wav Error /windows/default/wav Scan Accept /windows/default/wav Scan Reject /windows/default/wav Sounds Ctrl Panel » see text The 7535/7530 emits a beep under a variety of conditions. The “Audio” menu above lists the conditions under which your hand-held will sound.

Sounds Ctrl Panel This option displays the Volume & Sounds Properties dialog box. This dialog box is used adjust the beeper volume and to select the conditions under which the 7535/7530 will emit a beep.

Figure 6.8 Adjusting The Volume Important:

Refer to “Volume And Sound Properties” on page 108 for details about this dialog box.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

257

Page 284

Chapter 6: Tekterm Application Power Mgmt Ctrl Panel

6.16.3 Power Mgmt Ctrl Panel This menu item displays the Power Properties dialog box.

Figure 6.9 Power Properties Dialog Box Important:

Refer to “Power Management Properties” on page 109 for details about this dialog box.

6.16.4 User Permissions 04

User Permissions Screen Switch Y Font Change Y Exit N

Range Y/N Y/N Y/N

At User security level, the operator is restricted to a small group of parameters. Important:

Only Supervisor and Teklogix level passwords can change the values of the User options.

Screen Switch When set to “Y”, the operator can use the “Split screen” parameter to toggle between screens when multiple applications are running on the 7535/7530. Refer to “Split Screen” on page 261 for details about using this function.

258 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 285

Chapter 6: Tekterm Application Windows Properties

Font Change When “Font Change” is set to “Y”, operators at the User level can change the font size of their 7535/7530s. Pressing <CTRL> <ALT> <F> cycles through the available fonts.

Exit If this parameter is set to “Y”, an operator with user level security can exit Tekterm by pressing <ALT> <F4>. If “Exit” is set to “N”, the operator cannot exit Tekterm.

6.16.5 Windows Properties 04

Windows Properties Title Bar N Menu Bar N Block Move Y

Range Y/N Y/N Y/N

Title Bar When you set this parameter to “Y”, a title bar is displayed at the top of a window specifying the name of the application and the purpose of the window.

Menu Bar Setting this parameter to “Y” displays a horizontal bar below the title bar that contains a set of menus – Mode, Keyboard and Apps. You can tap on a menu name in the Menu Bar for quick access to a list of parameters to help with such activities as changing fonts, moving the cursor around the screen, panning the contents of the screen and working with TESS and ANSI applications.

Block Move Enabling (setting to “Y”) “Block Move” prevents the screen contents from moving when the Title Bar is visible.

6.16.6 Auto Start “Auto Start” determines whether or not Tekterm is automatically launched when the 7535/7530 is reset. If this parameter is set to “N”, Tekterm will not be launched when the hand-held resets.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

259

Page 286

Chapter 6: Tekterm Application Scanner Control Panel

6.17 Scanner Control Panel This menu item displays a Scanner Properties dialog box in which you can set up the particulars of your unit’s scanner performance, choose the bar codes which will be decoded, and so on.

Figure 6.10 Scanner Properties Dialog Box Important:

Refer to “Scanner Properties Setup” beginning on page 150 for details about setting up your scanner.

6.18 View Manager 04

View Manager Display Shift Y Block Cursor Y Use Increment N X-increment 5 Y-increment 5 Split Screen » Custom Chars » Font Override N» Default Colours»

Range Y/N Y/N Y/N 1..40 1..12 see text see text see text see text

Display Shift If this parameter is enabled (set to “Y”), the display in application screens shifts so that there are no blank columns on the left-most side of the display.

260 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 287

Chapter 6: Tekterm Application Split Screen

Block Cursor When this parameter is enabled (set to “Y”), the cursor is presented as a flashing block. When “Block Cursor” is set to “N”, the cursor is presented as a flashing underline character.

Use increment When “Use increment” is enabled (set to “Y”) and the cursor is moved off the display, the screen contents shift by the values specified in the “X-increment” and “Y-increment” parameters.

X-increment This parameter determines the number of spaces the screen shifts once the cursor moves out of view. The value assigned here doesn’t take effect until “Use Increment” is set to “Y”.

Y-increment This parameter determines the number of spaces the screen shifts once the cursor moves out of view. The value assigned here doesn’t take effect until “Use Increment” is set to “Y”.

6.18.1 Split Screen 04 Split screen Type 2 Way ||| View IDs A This parameter allows you to split the display view so that more than one application screen can be displayed at the same time. The split screen parameters, “Type” and “View IDs”, are used to tailor the screen view for your needs.

Type And View IDs The “Type” parameter determines how a screen will be split. The 7535/7530 supports up to four application screens. The “View IDs” parameter determines which application screens will be displayed in each pane of the split screen. “Moving Between Split Screens” on page 263 describes how to move the cursor from one split screen to the next.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

261

Page 288

Chapter 6: Tekterm Application Splitting And Displaying Screens

6.18.1.1 Splitting And Displaying Screens Before splitting the screen, you need to determine which applications should appear in each pane of the split screen. The available applications are listed in the main “Display Menu”. Each application listed in the “Display Menu” is preceded by a letter – for example, Parameters is preceded by an A. This letter is used in the “View IDs” string entry field to fix each pane of a split screen to a corresponding application. If you need to display the startup “Display Menu”: • Press <CTRL> <ALT><0>. To split a screen: • With the cursor on the “Type” parameter, use the <RIGHT> or <LEFT> arrow key to scroll through the types of split screens available. The vertical and horizontal lines displayed at the “Type” parameter indicate how the screen will be split – for example, in the sample screen on page 263, the vertical lines indicate the screen will be vertically split into two segments. The screen can also be split horizontally 3 ways or 4 ways. Once you’ve indicated how you want to split the screen in the “Type” parameter: •

Use the <DOWN> arrow key to move the cursor to the “View IDs” parameter.

•

For each application you want to display, type the letter corresponding to the application. For example, suppose you want to split the screen into two vertical segments with the “Parameters” menu in the left pane of the screen and a TESS session in the right pane. In the “Display Menu”, the letter A represents “Parameters” and B represents “TESS”. The “Type” and “View ID” values would be represented as follows: 04 Split screen Type 2 Way ||| View IDs AB

•

Press <ENTER>.

262 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 289

Chapter 6: Tekterm Application Moving Between Split Screens To display the split screen on the 7535/7530: •

Press <CTRL> <DOWN> arrow.

6.18.1.2 Moving Between Split Screens To move the cursor from one pane in a split screen to the next: •

Press <CTRL> <RIGHT> or <LEFT>. The cursor moves in order from the left-most pane to the right and from the top-most pane to the bottom.

6.18.1.3 Toggling Between Full & Split Screens To toggle between a split and full screen format: •

Press <CTRL> <DOWN> arrow.

The application displayed when toggling from a split to a full screen format is determined by the cursor location in the split screen. For example, if the cursor is in the pane of a split screen in which the TESS application is displayed and <CTRL> <DOWN> is pressed to display a full screen, the TESS application will be displayed in the full screen.

6.18.1.4 Using The Asterisk As A Wild Card When a screen is split, the application displayed in each pane is fixed in the “View IDs” parameter. Using an asterisk * in the “View IDs” parameter indicates that a particular pane in the split screen is not fixed to any particular application and can be changed as required. For example, suppose you want to split the screen into two vertical segments with the left pane containing the “Parameters” menu and the right pane containing no fixed application. The “Type” and “View IDs” parameters would be completed as follows: 04 Split screen Type 2 Way ||| View IDs A*

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

263

Page 290

Chapter 6: Tekterm Application Custom Characters (Unicode™) To change the application displayed in the pane with no fixed application: •

If the cursor is not currently in the pane, press <CTRL> <RIGHT> or <LEFT> arrow to move the cursor into the appropriate screen.

•

Press <CTRL> <ALT><0> to display the startup “Display Menu”.

•

Type the letter corresponding to the new application you want to display.

6.18.2 Custom Characters (Unicode™) Note:

The Unicode ™ characters created here are accessible only within the Tekterm application. To create Unicode ™ characters that are accessible system-wide, refer to “Unicode Mapping” on page 103.

The “Custom Characters” parameter allows you to create Unicode™ characters not available directly from the keyboard, including accented characters. Unicode is a trademark of The Unicode Consortium. You can create up to 20 Unicode™ characters that will be stored in a pop-up menu accessible from any application.

6.18.2.1 Creating A Unicode™ Character Note:

You can create a Unicode™ character by pressing and holding down the <ALT> while typing the decimal value that represents the Unicode™ character you want to use. However, you will need to press <ALT> and retype the decimal value each time you want to use the special character. The advantage to creating special characters using the “Custom Chars” parameters is that the characters you create in the customer characters table are saved in a pop-up window that is accessible from any application.

•

In the ‘Parameters’ menu, highlight “View Manager” and press <F1>.

•

Highlight “Custom Chars”, and press <F1> to display the custom characters table. 04 Custom Chars Font Small U+ 0000 U+ 0000 . . .

•

Position the cursor on the Fonts at the top of the table.

264 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 291

Chapter 6: Tekterm Application Displaying The Unicode™ Pop-up Window •

Press the <LEFT> or <RIGHT> arrow keys until the character set you want to use is displayed.

You can create up to 20 Unicode™ characters in the custom characters table. To create a Unicode™ value: •

Replace the 0000 value with a hex value that represents the Unicode™ character you want to use.

•

Press the <DOWN> arrow key to accept the value and move the cursor to the next field.

When you have finished creating the Unicode™ characters you want to use: •

Press <F4> to save your changes.

•

Reset the 7535/7530 – press and hold down the <ENTER> and <BLUE> key simultaneously for a minimum of six seconds.

6.18.2.2 Displaying The Unicode™ Pop-up Window The Unicode™ values you create are stored in a pop-up window that you can access from any application. To display the pop-up window within any application: • Note:

Press <CTRL> <ALT> <A>. Unicode™ characters that cannot be displayed on your screen with the font you are currently using are displayed as rectangles in the pop-up window. (See the sample menu on page 266.) However, the actual Unicode™ value you created will be sent to the host.

Select item with arrow keys. Press ENTER when done. Press ESC to cancel.

•

Use the <LEFT> or <RIGHT> arrow key to position the cursor on the Unicode™ value you want to use, and press <ENTER>. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

265

Page 292

Chapter 6: Tekterm Application Displaying The Unicode™ Pop-up Window To close the pop-up menu when you’re done: •

Press the <ESC> key.

Font Override Font Override 04 Font Code 0 ... is font 18x32 Font Code 1 ... is font 18x32 Font Code 2 ... is font 10x26 Font Code 3 ... is font 18x32 Font Code 4 ... is font 8x20 This parameter is used to redefine the font to which 5 different font codes refer.

Default Colours 04 Default Colours Foreground Black Background White

Range see text see text

Foreground And Background This menu is used to select the foreground and background colours used within Tekterm. If an unreadable combination is assigned – the foreground and background have the same value – the foreground colour will be inverted. The allowable values are: Red, Green, Yellow, Blue, Magenta, Cyan, White and Black. Note:

The 7535/7530 must be reset – press and hold down the <BLUE> and <ENTER> keys for a minimum of six seconds – in order for the new colour assignments to take affect.

266 Psion Teklogix 7535/7530 Hand-Held Computer User Manual