Page 333
Chapter 6: Tekterm Application Emulation
Features – 5250/Telnet 06
Features
Clear Entry Fields Passthru Printing AIAG Character Barcode Character Serial IO Character Fixed Field Ovrhd Enable Alarm Command Region Up Command Region Down Command Region Left Command Region Right
Range N N 0 0 0 5 N 0 0 0 0
Y/N Y/N 0-255 0-255 0-255 0-80 Y/N 0-24 0-24 0-80 0-80
These parameters are identical to those described for 2392/Telnet. Refer to “Features – 2392/Telnet” beginning on page 301.
FKEY0-7, FKEY8-15, FKEY16-23, FKEY24-31 And FKEY32-39 06 FKEY0-7 FKEY0 ENTER FKEY1 F1 FKEY2 F2 FKEY3 F3 FKEY4 F4 FKEY5 F5 FKEY6 F6 FKEY7 F7 The sub-menus attached to these parameters allow you to map the 7535/7530 function keys.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
307
Page 334
Chapter 6: Tekterm Application Ports, Tether And Console
6.20 Ports, Tether And Console 03 Ports Tether Port Settings 1 Console Port Settings 2 PR RS232 Settings 3 PR Tether Settings 4
Console » Disabled » Console » Console »
6.20.1 Peripheral Port Options The “Tether Port”, “Console Port” “PR RS232” and “PR Tether” options allow you to enable, disable and specify the accessories attached to these ports. These are: Disabled, Serial, Console, Printer and Scan-See. To scroll through the options for each port: •
Press the <RIGHT> or <LEFT> arrow key.
These ports operate differently depending on the accessories selected. •
Disabled – indicates that the serial port is not being used.
•
Serial – standard serial port.
•
Console – used to connect another PC to the 7535/7530. A communication program is required so that communication can proceed between the 7535/7530 and the PC.
•
Printer – all TESS print operations are directed to the port. All ANSI media copy operations to the “primary port” are directed to this port.
•
Scan-See – TESS and ANSI accepts input from the Scan-See through the Tether or Console port.
308 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 335
Chapter 6: Tekterm Application Port Parameter Settings
6.20.2 Port Parameter Settings The parameters for the “Tether Port”, “Console Port”, “PR RS232” and “PR Tether” are identical. 04
Settings
Character Set Baud Data Bits Parity Stop Bits Flow Ctrl Buffer Retries Input Tmo Output Tmo Shared Test
» 9600 8 none 1 None 512 3 2 5 N N
Range see text see text for range of baud rates 6..8 none odd even mark space 1, 1.5, 2 None Software Hardware Both 1..2048 1..100 1..100 1..100 Y/N Y/N
Character Set These menus define the character set for the 7535/7530 port. Important:
When a character sent from the host cannot be displayed, a right arrow character is used as a substitute. Char Set ISO N » IBM Y » DEC N » Misc. N »
This menu contains all the character sets available with your Psion Teklogix computer. In this menu, the “Y” or “N” are used to visually guide you to the selected character set. For example, in the sample menu above, the “Y” next to IBM indicates that a character set has been chosen from this group.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
309
Page 336
Chapter 6: Tekterm Application Port Parameter Settings
Choosing A Character Set To choose a character set: •
Position the cursor on the appropriate item – for example, ISO – and press <F1> to display the character set options.
•
To activate a character set, press the <RIGHT> or <LEFT> arrow key to set it to “Y”.
Important:
If you choose a Chinese character set from the ‘Misc.’ menu and a character sent from the host cannot be displayed on the screen, a shaded box character is used as a substitute. If you are using a Korean character set, a right arrow character is used as a substitute.
Baud This parameter determines the bit rate of the port. Allowable values include: 300 600 1200 2400 4800 9600 14.4kbps 19.2kbps 38.4kbps 57.6kbps 115.2kbps 128.0kbps or 256.0kbps.
Data Bits This parameter determines the number of bits for the data going through this port. Possible values are: 6, 7, 8.
Parity This parameter determines the type of parity checking used on the data going through the port. The options are: none, odd, even, mark and space.
Stop Bits This parameter specifies the number of stop bits – 1, 1.5, 2 – used for asynchronous communication.
Flow Control This parameter selects the type of flow control used in your hand-held computer. The 7535/7530 can perform Software or Hardware handshaking, or you can choose Both to enable both of these options. The function of each mode is as follows: Enable:Used to input and output data. Supports XON/XOFF or no handshaking. 310 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 337
Chapter 6: Tekterm Application Port Parameter Settings Print:
Used to output data only. All input characters except XON and XOFF are ignored. Supports XON/XOFF or no handshaking.
Output: Used to output data only. All input characters are ignored. Supports no handshaking. Note:
To enable the input and/or output, ‘serial in’ and/or ‘serial out’ must be enabled in the TESS menu.
Buffer The value assigned to this parameter determines the size of the serial buffer used by the application for both input and output. The buffer controls the amount of data the application can send to or receive from a serial device.
Retries This parameter determines the number of times the 7535/7530 attempts to transmit a byte from the serial port. If the count specified in this parameter is exceeded, the transmission fails.
Input Tmo This parameter sets the time in tenths of a second that the 7535/7530 waits before passing received data to the TESS or ANSI tasks.
Output Tmo The value assigned at this parameter determines the maximum number of milliseconds that the application will wait for a ‘write’ sent to the port to succeed before it is aborted. The ‘write’ may be one or several bytes in length.
Shared The “Shared” parameter allows a port to be shared by multiple sessions within TekTerm. If it is not enabled (set to “Y”), the first session to access the port has sole use of it.
Test When this parameter is enabled (set to “Y”), data is output through the serial port to make certain that it is operating appropriately.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
311
Page 338
Chapter 6: Tekterm Application Port Scan-See Parameters
6.20.3 Port Scan-See Parameters When ‘Scan-See’ is specified as the peripheral for a port, the parameters listed under the “Scan-See” sub-menu are used to tailor the operation of this type of scanner. The other parameters listed in this menu – “Character Set”, “Baud” and so on – are identical to those described beginning on page 308. Scan See 05 Character Set» » Baud 9600 9600 Data Bits8 8 Paritynone none Stop Bits1 1 Retries3 3 Input Tmo2 2 Scan-See »
6.20.3.1 Scan-See Sub-Menu – Mapping The Viewport 05 Scan-See Anchor Line Anchor Column Follow Cursor Line Offset Column Offset Wraparound Panning Line Scrolling Brightness Arrows Version
Range 1 19 Y 0 0 N Y N 3 Bright 2
0...1 0...19 Y/N -25...25 -80...80 Y/N Y/N Y/N 0 to 5 Bright Horz Vert 0...2
The Scan-See display is mapped to a specific area on the 7535/7530 screen – called the viewport – and is continuously updated to reflect that portion of the screen. The Scan-See viewport is defined as follows:
312 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 339
Chapter 6: Tekterm Application Scan-See Sub-Menu – Mapping The Viewport
Anchor Line/Anchor Column A location on the Scan-See display – the anchor – is chosen as a reference point.
Line Offset/Column Offset A predefined displacement – the offset – is added to the location of the 7535/7530 cursor to create a point – the pivot . This pivot is mapped to the anchor , and whatever is displayed in its vicinity is also displayed on the Scan-See. For example: • the anchor is chosen as (9,0) whereas “9” is the column and “0” is the line (on the Scan-See display)
• the offset is chosen as (4,2)
• the cursor on the 7535/7530 is currently located at (7,5)
• the pivot would thus be located at (7+4, 5+2) or (11,7)
• and so the area displayed on the Scan-See will be: (11–9,7–0) to (11–9+9,7–0+1) or (2,7) to (11,8). 1
1 These computations assume that “Wraparound” (described on page 315) is disabled (set to “N”) and that “Follow Cursor” (described on page 315) is enabled (set to “Y”).
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
313
Page 340
Chapter 6: Tekterm Application Scan-See Sub-Menu – Mapping The Viewport
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 . . . 0 1
(0,0)
terminal cursor
2 3 4
(7,5) +4
5 offs
6 anchor (0,0)
+2
(11, 7)
8
(4
,2) et
+2
9
0 1 2 3 4 5 6 7 8 9 0 et
7
+4 offs
(9,0)
pivot = terminal cursor + offset
10
Scan-See Display
...
11
1
Terminal Display superimposing the anchor on the pivot
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 . . . 0 1
(0,0)
2 anchor
3 4 5 6
(2,7 )
(11, 7)
pivot
7
(11, 8)
8 9
Scan-See Viewport
10
...
11
Note:
To enter negative values, press the “-” (minus) key and then, type the number you want to use. The <LEFT> arrow key can also be used to decrement the value assigned to the parameter. Each time the <LEFT> arrow is pressed, the number is decremented by one. For example, to enter a value of “–5”, start from zero and press the left arrow key five times.
314 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 341
Chapter 6: Tekterm Application Scan-See Sub-Menu – Mapping The Viewport
Follow Cursor When the “Follow Cursor” parameter is disabled (set to “N”), the cursor is always assumed to be located at the origin. Using the previous example: • the area displayed will be (4–9,2–0) to (4–9+9, 2–0+1), or, after clipping values that are negative or higher than 80: (0,2) to (4,3).
Wraparound When “Wraparound” is enabled (set to “Y”), the Scan-See display is treated as a one-line by 20 column display, rather than 2 lines by 10 columns.
Panning If “Panning” is disabled (set to “N”), the Scan-See viewport does not move when the cursor moves one position to the right, and the pivot is still inside the Scan-See display. However, the Scan-See display is updated to reflect the changes within that viewport. If the pivot goes outside the viewport, or if the 7535/7530 display changes without the cursor being moved, the viewport is re-synchronized to coincide the pivot with the anchor.
Line Scrolling When “Line Scrolling” is enabled (set to “Y”), the Scan-See display is treated as two separate one line by 10 column displays. The top line always displays the previous value of the bottom line. In an application where the cursor skips from one entry field to another, the field that the cursor just entered is displayed on the top line, and the next field is displayed at the bottom. Note:
When this feature is enabled (set to “Y”), the “Panning” option should be disabled to prevent updates to both lines after every keystroke
Brightness The “Brightness” parameter controls the backlight brightness of the display. It only has an effect on Model 7000 Scan-Sees – scanners equipped with LED (light emitting diode) displays.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
315
Page 342
Chapter 6: Tekterm Application Scan-See Keyboard Mapping
Arrows The “Arrows” parameter assigns one of three possible functions to the two arrow keys on the Scan-See keyboard:
Value
Function
Bright
Arrow keys control Scan-See display brightness.
Horiz
Arrow keys control “Column Offset”.
Vert
Arrow keys control “Line Offset”.
Table 6.5 “Arrow” Parameter Options Note:
For “Horiz” and “Vert,” changing the offset will take affect only after the 7535/7530 display has been updated.
Version Scan-See units with serial numbers that read 1594120224 or higher contain firmware that implements a different communication protocol with the 7535/7530 than older units. The “Version” numbers represent the following unit versions:
Value
Scan-See Version First LED version – up to serial number 1594080275; these are encased in grey plastic. Model 7000 LED units – versions after the serial number above; these are also encased in grey plastic. Metrologic 7000M LCD units; these are encased in grey plastic. Psion Teklogix 7000M LCD units; these are encased in black plastic.
0 1 2
Table 6.6 Scan-See Versions Note:
To interface the 7535/7530 to the Scan-See units with older firmware (serial number lower than 1594120224), set “Parity = space”; all other parameters are identical to the newer firmware.
6.20.3.2 Scan-See Keyboard Mapping •
Digits (0-9) are passed verbatim
•
The CLR key forces a sign-on message and display refresh. This only occurs when CLR is pressed and the CLR key on the display is pressed, then released.
316 Psion Teklogix 7535/7530 Hand-Held Computer User Manual