Chapter 5: Configuration Discrete 2 of 5 Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 6 to 55.

Check Digits Double-tapping on this parameter displays a dialog box in which you can choose One or Two check digit(s). If this parameter is set to One, it is assumed that the last digit is a check digit. If “Check Digits” is set to Two, it is assumed that the last two digits are check digits. Note:

If Two check digits is selected, an MSI Plessey “Check Digit Algorithm” must also be selected. See page 9-88.

Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data.

Check Digit Algorithm When the Two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Double-tapping on this parameter displays a dialog box in which you can choose the algorithm to be used: MOD 10/MOD 11 or MOD 10/MOD 10.

Field Size/Chars Refer to page 154 for details.

5.10.3.14 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”.

Set Length L1 And Set Length L2 Lengths for “Discrete 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

175

Page 202

Chapter 5: Configuration 2D PDF-417 Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 12.

Field Size/Chars Refer to page 154 for details.

5.10.3.15 2D PDF-417 Enable Setting this parameter to on enables PDF-417 two dimensional (2D) coding.

Field Size/Chars Refer to page 154 for details.

5.10.3.16 2D Micro PDF-417 Enable Setting this parameter to on enables “2D Micro PDF-417” bar code scanning. Micro PDF-417 is a multi-row symbology that is useful for applications requiring greater area efficiency but lower data capacity than PDF-417.

Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 if the first codeword is 903-907, 912, 914, 915 ]C2 if the first codeword is 908 or 909 ]C0 if the first codeword is 910 or 911 If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 ]L4 ]L5 if the first codeword is 903-907, 912, 914, 915 if the first codeword is 908 or 909 if the first codeword is 910 or 911

176 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 203

Chapter 5: Configuration 2D RSS Code (Reduced Space Symbology)

Field Size/Chars Refer to page 154 for details.

5.10.3.17 2D RSS Code (Reduced Space Symbology) Enable Setting this parameter to on enables “2D RSS Code” scanning capability.

Enable RSS-14 RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned.

Enable RSS Limited ‘RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1. It is not stackable and is not designed to be read omni-directionally.

Enable RSS Expanded ‘RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but they can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS Expanded” code can be omni-directionally scanned.

Field Size/Chars Refer to page 154 for details.

5.10.3.18 Composite Important:

To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled. In addition, “Center Bar Code Only” must be disabled.

A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. The options available for this parameter represent multi-level components of a composite symbol. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

177

Page 204

Chapter 5: Configuration Decoded (Intermec ISCP)

Enable CC-C And Enable CC-AB To activate these components, set the parameters to on.

Enable TLC-39 This composite component integrates MicroPDF417 with the linear code. Setting this parameter to on enables this parameter.

5.10.4 Decoded (Intermec ISCP)

Figure 5.77 Decoded Intermec Scanner •

Tap on the Scanner dropdown menu, and choose Decoded (Intermec ISCP).

5.10.4.1 Code 39 Enable Setting this parameter to on enables “Code 39”.

Field Size/Chars Refer to page 154 for details.

5.10.4.2 Code 128 Setting this parameter to on enables “Code 128”.

178 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 205

Chapter 5: Configuration UPC A

Field Size/Chars Refer to page 154 for details.

5.10.4.3 UPC A Enabled Set this parameter to on to enable “UPC A” bar code scanning recognition.

Prefix/Suffix Refer to page 157 for details.

5.10.4.4 UPC E Enabled Set this parameter to on to enable “UPC E”.

Prefix/Suffix Refer to page 157 for details.

5.10.4.5 EAN 8 Enabled Set this parameter to on to enable “EAN 8”.

Prefix/Suffix See “Prefix/Suffix” beginning on page 157.

5.10.4.6 EAN 13 Enabled Set this parameter to on to enable “EAN 13”.

Prefix/Suffix See “Prefix/Suffix” beginning on page 157.

5.10.4.7 UPC/EAN Shared Settings The setting assigned to the “Addendum” parameter associated with this option is shared across all UPC and EAN bar codes. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

179

Page 206

Chapter 5: Configuration Interleaved 2 of 5

Addendum Refer to “Addendum” on page 157.

5.10.4.8 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”.

Field Size/Chars Refer to page 154 for details.

5.10.4.9 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”.

Field Size/Chars Refer to page 154 for details.

5.10.4.10 Code 11 Enabled Set this parameter to on to enable “Code 11”.

Field Size/Chars Refer to page 154 for details.

5.10.4.11 Codabar Enabled Set this parameter to on to enable “Codabar”.

Field Size/Char Refer to page 154 for details.

180 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 207

Chapter 5: Configuration Code 93

5.10.4.12 Code 93 Enabled Set this parameter to on to enable “Code 93”.

Field Size/Char Refer to page 154 for details.

5.10.4.13 MSI Plessey Enabled Set this parameter to on to enable “MSI Plessey”.

Field Size/Char Refer to page 154 for details.

5.10.5 Imager

Figure 5.78 Imager •

Tap on the Scanner dropdown menu, and choose Imager.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

181

Page 208

Chapter 5: Configuration Options – Imager

5.10.5.1 Options – Imager Dot Time (msec) The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of between 0 and 3000. A value of 0 disables the target dot.

Center Bar Code Only Note:

This parameter must be disabled when reading Composite bar codes.

When more than one bar code is visible in a single snap shot, this parameter allows you to specify that only the centre image within the imager framing marker be read. When this parameter is set to on, the target dot is pointed at the centre image and only that image is returned.

Auto Exposure Important:

This parameter value should only be changed by qualified Psion Teklogix personnel. It should be left at the default value – ‘on’. Setting this parameter to on allows the imager to make automatic gain, integration and illumination adjustments based on ambient light before capturing the bar code. If the adjustment is insufficient, further adjustments are made automatically before another image is captured.

Fast Converge Note:

“Auto Exposure” must be set to ‘on’ in order for this parameter to function. Keep in mind that while this parameter can improve imager performance, “Fast Converge” increases battery power consumption.

Setting this parameter to on speeds the “Auto Exposure” process. It allows the imager to rapidly snap a number of bar code capture attempts while finding ideal values for gain, integration and illumination.

182 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 209

Chapter 5: Configuration Code 39

Max Gain, Max Integration And Max Illumination Important:

These parameter values should only be changed by qualified Psion Teklogix personnel. These parameters represent internal units used by the Symagery imager. The “Auto Exposure” parameter automatically adjusts the “Max Gain”, “Max Integration” and “Max Illumination” parameters to produce the best bar code read. Keep in mind that “Auto Exposure” must be set to on in order for these parameter values to be automatically adjusted. Double-tapping on any of these parameters displays an associated dialog box in which an allowable range is displayed: Max Gain – 357 to 7920, Max Integration – 0 to 65535, Max Illumination – 0 to 7.

5.10.5.2 Code 39 Enabled Set this parameter to on to enable “Code 39”.

Field Size/Chars Refer to page 154 for details.

5.10.5.3 Code 128 Enabled Set this parameter to on to enable “Code 128.

Field Size/Chars Refer to page 154 for details.

5.10.5.4 UPC/EAN This parameter allows you to enable the following UPC (Universal Product Code) and EAN (European Article Numbering) bar codes: UPC-A, UPC-E, UPC-E1, UPC-8, EAN-13, Bookland EAN-13 and Bookland EAN.

Enabled Set this parameter to on to enable “UPC/EAN” bar codes.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

183

Page 210

Chapter 5: Configuration Codabar

Addendum Refer to “Addendum” on page 157.

Prefix/Suffix Refer to page 157 for details.

5.10.5.5 Codabar Enabled Set this parameter to on to enable “Codabar”.

Field Size/Char Refer to page 154 for details.

5.10.5.6 Code 93 Enabled Set this parameter to on to enable “Code 93”.

Field Size/Char Refer to page 154 for details.

5.10.5.7 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”.

Field Size/Chars Refer to page 154 for details.

5.10.5.8 Postal: Australian Enabled Set this parameter to on to enable “Postal: Australian”.

Field Size/Chars Refer to page 154 for details.

184 Psion Teklogix 7535/7530 Hand-Held Computer User Manual