Page 191
Chapter 5: Configuration Data Options, Decoded (Internal) Scanner
Note:
These parameters are only used when either Programmable Raster or Always Raster is assigned to the “2D Scanning Mode” parameter. “2D Raster Height” and “2D Raster Expand Rate” are intended for very specific applications and are usually not required for normal scanning purposes.
Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 15.
5.10.3.2 Data Options, Decoded (Internal) Scanner Transmit Code ID Char A code ID character identifies the scanned bar code type. In addition to any single character prefix already selected, the code ID character is inserted between the prefix and the decoded symbol. When you double-tap on this parameter, a dialog box is displayed in which you can choose a transmit code: None, AIM or Symbol.
Scan Data Format This parameter allows you to change the scan data transmission format. Double-tapping on “Scan Data Format” displays the following options from which you can choose a data format: data (as-is), data <S1>, data <S2>, data <S1><S2>, <P> data, <P> data <S1>, <P> data <S2> and <P> data <S1><S2>.
Prefix <P>, Suffix <S1> And Suffix <S2> A prefix and/or one or two suffixes may be appended to scan data for use in data editing. When you double-tap on these parameters, a dialog box is displayed in which you can enter a value from 0 to 255.
Delete Char Set ECIs Setting this parameter to on enables the scanner to delete any escape sequences representing Character Set ECIs – Extended Channel Interpretations (also known as GLIs) from its buffer before transmission.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
165
Page 192
Chapter 5: Configuration Code 39 When this parameter is enabled, the scanner transmits data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled.
ECI Decoder Setting this parameter to on enables the scanner to interpret any Extended Channel Interpretations (ECIs) supported by the scanner. This parameter has no effect on symbols that were not encoded using ECIs. If this parameter is set to off and a symbol that was encoded using an ECI escape is scanned, the scanner transmits the ECI escape followed by the uninterpreted data.
5.10.3.3 Code 39 Enable Setting this parameter to on enables “Code 39”.
Enable Trioptic Code 39 Note:
“Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies.
Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.
Convert To Code 32 Note:
“Code 39” must be enabled in order for this parameter to function.
Setting this parameter to on allows the scanner to convert the bar code from “Code 39” to “Code 32”.
Code 32 Prefix Note:
“Convert to Code 32” must be enabled in order for this parameter to function.
When this parameter is enabled, the prefix character “A” is added to all “Code 32” bar codes.
166 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 193
Chapter 5: Configuration Code 39
Set Length L1 And Set Length L2 Lengths for “Code 39” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be decoded by your scanner.
Figure 5.76 Setting Code Lengths Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 55.
Check Digit Verification When this parameter is enabled, the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms. Note:
Only those “Code 39” symbols that include a Mod 43 check digit are decoded when this parameter is enabled.
Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must to enabled.
Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
167
Page 194
Chapter 5: Configuration Code 128
Decode Performance If this parameter is enabled, one of three decode levels can be chosen in the “Decode Performance Level” parameter.
Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3.
Field Size/Chars Refer to page 154 for details.
5.10.3.4 Code 128 Enabled Set this parameter to on to enable “Code 128”.
Enable UCC/EAN-128 EAN/UCC bar codes include group separators and start codes. To successfully scan this type of bar code, “EAN/UCC 128” must be enabled.
Enable ISBT 128 To successfully scan this type of bar code, this option must be set to on.
Decode Performance If this parameter is set to on, one of three decode levels assigned to the “Decode Performance Level” parameter can be selected.
Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 128 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. 168 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 195
Chapter 5: Configuration EAN 13 When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3.
Field Size/Chars Refer to page 154 for details.
5.10.3.5 EAN 13 Enabled Set this parameter to on to enable “EAN 13”.
Prefix/Suffix See “Prefix/Suffix” beginning on page 157.
5.10.3.6 EAN 8 Enabled Set this parameter to on to enable “EAN 8”.
EAN-8 Zero Extend When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols, making them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format.
Prefix/Suffix See “Prefix/Suffix” beginning on page 157.
5.10.3.7 UPC A Enabled Set this parameter to on to enable “UPC A”.
UPC-A, Check Digit If you enable this parameter, the check digit is included with the decoded bar code data.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
169
Page 196
Chapter 5: Configuration UPC E
UPC-A, Preamble When you double-tap on this parameter, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-A symbols transmitted to the host device: System Char – system character transmitted with the data, Country code and System Char – both the country code (“0” for USA) and system character are transmitted with the data or None – no preamble is transmitted. The lead-in characters are considered part of the symbol.
Prefix/Suffix See “Prefix/Suffix” beginning on page 157.
5.10.3.8 UPC E Enabled UPC-E Set this parameter to on to allow “UPC E” bar code scans.
Enabled UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans.
UPC-E And UPC-E1 Check Digit If you enable one or both of these parameters, a check digit is included with the decoded bar code data.
UPC-E And UPC-E1 Preamble When you double-tap on one of these parameters, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-E and UPC-E1 symbols transmitted to the host device: System Char – system character transmitted with the data, Country code and System Char – both the country code (“0” for USA) and system character are transmitted with the data or None – no preamble is transmitted. The lead-in characters are considered part of the symbol.
Conv. UPC-E To UPC-A This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
170 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 197
Chapter 5: Configuration UPC/EAN Shared Settings
Conv. UPC-E1 To UPC-A This parameter converts UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
Prefix/Suffix See “Prefix/Suffix” beginning on page 157.
5.10.3.9 UPC/EAN Shared Settings The parameters you set here are a shared across all available UPC and EAN bar codes.
Enable Bookland EAN Setting this parameter to on allows your scanner to recognize Bookland EAN bar codes.
Supplementals 'Supplementals” are additionally appended characters (2 or 5). Double-tapping this parameter displays a list of options. If Ignore is chosen, UPC/EAN is decoded and the supplemental characters are ignored. If Decode is chosen, UPC/EAN symbols are decoded with supplementals. Autodiscriminate works in conjunction with the Supp. Redundancy parameter.
Supp. Redundancy With “Autodiscriminate” selected in the “Supplementals” parameter, “Supp. Redundancy” adjusts the number of times a symbol without supplementals is decoded before transmission. When you double-tap on this parameter, a dialog is displayed in which you can enter a value between 2 and 20. A value of 5 or above is recommended when Autodiscriminate is selected and you are decoding a mix of UPC/EAN symbols with and without supplementals.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
171
Page 198
Chapter 5: Configuration Codabar
Security Level This parameter controls the tolerance for decoding edge-to-edge UPC/EAN bar codes. Double-tapping on this parameter displays a dialog box in which you can choose a level from 0 to 3. Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code.
Linear Decode “Linear Decode” applies to code types containing two adjacent blocks (e.g., UPC-A, EAN-8, EAN-13). When enabled (set to on), a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other.
2D UPC Half Block Stitching Setting this parameter to on enables “UPC Half Block Stitching” for the SE 3223 omnidirectional engine only.
5.10.3.10 Codabar Enabled Set this parameter to on to enable “Codabar”.
Set Length L1 And Set Length L2 Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 5 to 55.
172 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 199
Chapter 5: Configuration Code 93
CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note:
Symbol length does not include start and stop characters.
NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.
Field Size/Chars Refer to page 154 for details.
5.10.3.11 Code 93 Enabled Set this parameter to on to enable “Code 93”.
Set Length L1 And Set Length L2 Lengths for “Code 93” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 55.
Field Size/Chars Refer to page 154 for details.
5.10.3.12 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
173
Page 200
Chapter 5: Configuration MSI Plessey
Set Length L1 And Set Length L2 Lengths for “Interleaved 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 14.
Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council).
Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data.
Convert To EAN 13 If this parameter is enabled, an I 2 of 5 bar code is converted to EAN 13.
Field Size/Chars Refer to page 154 for details.
5.10.3.13 MSI Plessey Enabled Set this parameter to on to enable “MSI Plessey”.
Set Length L1 And Set Length L2 Lengths for “MSI Plessey” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. 174 Psion Teklogix 7535/7530 Hand-Held Computer User Manual