Page 181

Chapter 5: Configuration Code 128

Prefix Char This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialog box resets the data to zero.

Suffix Char Note:

The appended character is treated as any other keyboard character. For example, if <BKSP> is pressed, the usual action for that key is performed. If your unit is operating with the Psion Teklogix ANSI emulation application, the hand-held transmits the escape sequence associated with the function immediately after the bar code data.

This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialog box resets the data to zero.

Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Note:

For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”.

Strip Trailing The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

5.10.2.3 Code 128 Enabled Set this parameter to on to enable “Code 128” or off to disable it.

Include Sym Setting “Include Sym” to on causes the group separator(s) and start code contained in this type of bar code to be displayed on the screen. Note:

This option is available only when ‘EAN/UCC 128’ is selected.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

155

Page 182

Chapter 5: Configuration EAN 13

Variations When using Code 128, you can choose the bar code variation the scanner will recognize. The options available are Standard, UCC 128 and EAN/UCC 128. •

Double-tap on Variations to display a dialog box listing your options.

• Tap on a variation to highlight it, and then tap on OK. If you choose None, a check is not executed.

Standard Enable Standard if “Code 128” is desired.

UCC 128 UCC 128 is a variation of “Code 128”.

EAN/UCC 128 To successfully scan this type of bar code, “EAN/UCC 128” must be enabled. “EAN/UCC” bar codes include group separators and start codes.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.4 EAN 13 Enabled Set this parameter to on to enable “EAN 13” or off to disable it.

Include Country If this parameter is enabled, the country code is included with the decoded bar code data.

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

156 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 183

Chapter 5: Configuration EAN 13

Addendum Important:

Before “Addendum” can take effect, the “Short Code” parameter (see page 153) must be enabled.

An addendum is a separate bar code, supplementary to the main bar code. This parameter provides three options: Disabled, Optional and Required. Depending on the value chosen for this parameter, an addendum is recognized or ignored. •

Double-tap on Addendum to display a dialog box listing your options.

• Highlight an item, and tap on OK. When “Addendum” is set to Disabled, the scanner does not recognize an addendum. If this parameter is set to Optional, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required, the scanner does not accept the main bar code without an addendum.

Prefix/Suffix Prefix Char This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialog box resets the data to zero.

Suffix Char This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialog box resets the data to zero.

Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Note: The appended character is treated as any other keyboard character. For example, if <BKSP> is pressed, the usual action for that key is performed. If your hand-held is operating with the Psion Teklogix ANSI emulation application, the hand-held transmits the escape sequence associated with the function immediately after the bar code data. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

157

Page 184

Chapter 5: Configuration EAN 8

Strip Trailing The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

5.10.2.5 EAN 8 Enabled Set this parameter to on to enable “EAN 8” or off to disable it.

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

Addendum Important:

Before “Addendum” can take effect, the “Short Code” parameter (see page 153) must be enabled. Refer to “Addendum” on page 157.

Prefix/Suffix See “Prefix/Suffix” beginning on page 157.

5.10.2.6 UPC A Enabled Set this parameter to on to enable “UPC A”.

Include Number Sys If this parameter is enabled, the number system digit is included with the decoded bar code data.

Include Check If this parameter is enabled, the check digit will be included with the decoded bar code data.

Addendum Important:

Before “Addendum” can take effect, the “Short Code” parameter (see page 153) must be enabled. Refer to “Addendum” on page 157. 158 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 185

Chapter 5: Configuration UPC E

Prefix/Suffix Refer to page 157 for details.

5.10.2.7 UPC E Convert to UPC-A Setting this parameter to on results in a non-standard decoding that returns 12 digits from the 6 digit UPC E bar code.

Include Number Sys If this parameter is enabled, the number system digit is included with the decoded bar code data.

Include Check When enabled, the check digit is included with the decoded bar code data.

Addendum Important:

Before “Addendum” can take effect, the “Short Code” parameter (see page 153) must be enabled. Refer to “Addendum” on page 157.

Prefix/Suffix Refer to page 157 for details.

5.10.2.8 Codabar Enabled Set this parameter to on to enable “Codabar” or off to disable it.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.9 Code 93 Enabled Set this parameter to on to enable “Code 93”.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

159

Page 186

Chapter 5: Configuration Code 11

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.10 Code 11 Enabled Set this parameter to on to enable “Code 11”.

Include Check If “Include Check” is enabled, the check digit is included with the decoded bar code data.

Check Digit This parameter can be set to None, One Check Digit or Two Check Digits. •

Double-tap on this parameter to display a dialog box listing your options.

• Highlight the check digit you want to use, and tap on OK. If this parameter set to One Check Digit, it is assumed that the last digit is a check digit. If this parameter is set to Two Check Digits, it is assumed that the last two digits are check digits.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.11 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”.

Mod 10 Check If this parameter is enabled, the “Mod 10” check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.

ITF Check If this parameter is enabled, the ITF-14/16 Mod10 check digit is calculated.

160 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 187

Chapter 5: Configuration MSI Plessey

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.12 MSI Plessey Enabled Set this parameter to on to enable “MSI Plessey”.

One Check Digit If this parameter is enabled, it is assumed that the last digit is a check digit.

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.13 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”.

Mod 10 Check If this parameter is enabled, the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.

ITF Check If this parameter is enabled, the ITF-14/16 Mod10 check digit is calculated.

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

161

Page 188

Chapter 5: Configuration IATA 2 of 5

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.2.14 IATA 2 of 5 Enabled Set this parameter to on to enable “IATA 2 of 5”.

Mod 10 Check If this parameter is enabled, the Mod 10 check digit is calculated.

ITF Check If this parameter is enabled, the ITF-14/16 Mod10 check digit is calculated.

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

Field Size/Chars Refer to the description beginning on page 154 for details.

5.10.3 Decoded (Internal) Scanners

Figure 5.75 Decoded (Internal) Scanner •

Tap on the Scanner dropdown menu, and choose Decoded (internal).

162 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 189

Chapter 5: Configuration Options, Decoded (Internal) Scanner

5.10.3.1 Options, Decoded (Internal) Scanner Dot Time (msec) The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 msec or 400 msec. A value of 0 (zero) disables the target dot.

Laser On Time The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 5 and 99, each number representing 0.1 seconds.

Low Power Timeout To extend laser life, you can select the time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned – a successful decode restores normal blinking. When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec, 1 min, 2 min or 3 min.

Parameter Scanning Setting this parameter to on enables decoding of parameter bar codes.

Linear Security Level This parameter allows you to select the security level appropriate for your bar code quality. There are four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels should be selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases. Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 4.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

163

Page 190

Chapter 5: Configuration Options, Decoded (Internal) Scanner “Linear security level 1” specifies that the following code types must be successfully read twice before being decoded:

Code Type

Length

Codabar

All

MSI Plessey

4 or less

D 5 of 5

8 or less

I 2 of 5

8 or less

“Linear security level 2” specifies that all types of codes must be successfully read twice before being decoded. “Linear security level 3” specifies that code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:

Code Type

Length

MSI Plessey

4 or less

D 2 of 5

8 or less

I 2 of 5

8 or less

“Linear security level 4” requires that all code types be successfully read three times before being decoded.

Bi-Direction Redundancy Note:

This parameter is only valid if a” Linear Security Level” is enabled.

When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

2D Scanning Mode When you double-tap on this parameter, a dialog box is displayed in which you can choose one of the following scanning modes: Smart Raster, Always Raster, Programmable Raster, Slab Pattern, Cyclone Pattern or Semi-Omni Pattern.

2D Raster Height And 2D Raster Expand Rate These parameter determine the laser pattern’s height and rate of expansion.

164 Psion Teklogix 7535/7530 Hand-Held Computer User Manual