Page 171

Chapter 5: Configuration Protocol Tab

Polling The default values for the Polling parameters are dependent on the value assigned to the Modulation / Baud Rate parameter in the Radio tab.

Modulation / Baud Rate

Sync Delay

Window Delay Poll Timeout

4 Level / 19200

17

20

20

4 Level / 9600

17

23

25

2 Level / 9600

17

19

22

2 Level / 4800

25

23

37

Table 5.3 Polling Parameters Sync Delay Warning:

This parameter should not be changed from its factory setting without a clear understanding of radio protocol timing.

The “Sync Delay” parameter specifies the delay between the base station transmission and the first response window, measured in milliseconds. The value assigned to this parameter must be compatible with other hand-helds and base stations in the system. The allowable range for this parameter is between 1 and 40.

Window Delay Important:

The value assigned to this parameter should not be changed from the factory setting without a clear understanding of the timing of the radio protocol.

This parameter specifies the amount of time (in milliseconds) the 7530 should add to each response window in order to accommodate the receive/transmit switching characteristics of the radio. The value assigned must be compatible with other units and base stations in the system. The default setting of 19 is based on the requirements of a 2 level modulation narrow band radio, operating at 9600 baud.

Poll Timeout This parameter (in units of 16.6 ms) sets the time-out value used for automatic channel switching. “Poll Timeout” is the time during which the 7530 should detect at least one poll from a base station. As each “Poll Timeout” passes without a successful poll from the base station, the 7530 channel quality decreases. If the channel quality falls to below 46%, the unit begins searching for a new channel. A value from 1 to 200 can be assigned to this parameter. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

145

Page 172

Chapter 5: Configuration Power Tab

Late TX Limit The value entered for this parameter (measured in milliseconds) sets the maximum allowable deviation time from the start of a response window during which an 7530 can make a transmission. After this threshold, the transmission will not be attempted and the 7530 will try again at the next opportunity. For example, suppose this parameter is set to 5. From the beginning of the response window, the 7530 can be up to 5 milliseconds late sending a transmission. Beyond this threshold, the transmission is not attempted. The hand-held waits for the next opportunity. The allowable range for this parameter is from 1 and 10 – the default value is 2.

Test Polling Values •

Tap on the Test Polling Values button to test the polling values indicated in this dialog box without committing them to memory.

To commit the new polling values to memory: •

Tap on the OK button – the dialog box is closed and the new values are saved.

To discard the new values, and retain the existing values: •

Tap on the X button at the top of the dialog box.

5.9.4 Power Tab

Figure 5.69 Power Tab 146 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 173

Chapter 5: Configuration Radio Tab

Enable Power Saving When this parameter is checked, power saving is enabled.

Idle Poll Limit Note:

The “Idle Poll Limit” parameter is only used when “Enable Power Saving” is enabled.

This parameter determines how many transmit opportunities – base station polls with available response windows – must be consecutively skipped before the 7530 places the radio into power-down mode for power saving. The allowable range for this parameter is from 1 to 200. The default value is 10. Lower values cause the hand-held to enter power saving mode quickly, extending battery life but reducing 7530 responsiveness. Higher values increase responsiveness but decrease battery life.

Power Off Time This parameter determines the amount of time (in seconds) the 7530 radio stays in power-down mode when a power down period has been initiated. “Power Off Time” is only used when the “Enable Power Saving” parameter is enabled. The allowable range for this parameter is 1 to 60.

5.9.5 Radio Tab

Figure 5.70 Radio Tab

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

147

Page 174

Chapter 5: Configuration Radio Tab

Modulation/Baud Rate The options listed in the “Modulation / Baud Rate” dropdown menu are: 2 Level/4800, 2 Level/9600, 4 Level/9600 and 4 Level/19200. The value assigned to this parameter must be identical to the corresponding parameter in the Psion Teklogix Base Station. This parameter is stored in the radio’s non-volatile memory. The default value for “Modulation/Baud Rate” is 2 Level/9600

Data Squelch “Data Squelch” controls the radio receiver, cutting it off when the signal is too weak for reception of anything but noise. Receive Signal Strength Indicator values below the “Data Squelch” threshold prevent further processing of the receive signal while higher values allow further processing. The allowable range is 0 to 100 with a default value of 0. In noisy environments, this value can be increased to reject noise. In environments with less noise, this value can be decreased to allow the received signal and increase range. This parameter is stored in the radio’s non-volatile memory.

Test Squelch •

Tap on the Test Squelch button to prompt the radio to use the “Data Squelch” value without committing it to the radio’s non-volatile memory – in other words, to ‘test’ the value assigned to the “Data Squelch” parameter.

To commit the new “Data Squelch” value to the radio’s non-volatile memory: •

Tap on the OK button – the dialog box is closed and the new value is saved.

To discard the new value, and keep the old “Data Squelch” value: •

Tap on the X button at the top of the dialog box. The old value is sent to the protocol driver.

148 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 175

Chapter 5: Configuration Radio Tab

Frequency Table •

Tap on the Frequency button to display the Frequency Table dialog box.

Figure 5.71 Frequency Table •

Tap on the Copy “Receive” to “Transmit” button to copy the contents of the “Receive” fields into the corresponding “Transmit” fields.

When you tap on this button, a warning box is displayed asking Copy all the Rx frequencies to the Tx frequencies? •

Tap on the Yes button to go ahead or No to stop the copy process.

Statistics •

Tap this button to display communication statistics.

Refer to “Statistics Screen” beginning on page 137 for details about this screen.

Advanced This button launches the “Radio Test Application”.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

149

Page 176

Chapter 5: Configuration Scanner Properties Setup

5.10 Scanner Properties Setup The Teklogix Scanners icon in the Control Panel provides dialog boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize.

Figure 5.72 Teklogix Scanner Icon

5.10.1 Bar Codes

Figure 5.73 Scanner Properties

150 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 177

Chapter 5: Configuration Bar Codes

The Scanner The dropdown menu to the right of the Scanner option allows you to choose from one of the following scanner types used with your hand-held: Non-decoded, Decoded (internal), Decoded (Intermec ISCP), Imager and Decoded (external). The symbologies listed in the Barcodes tab change to reflect the scanner you choose and the bar codes it supports. Important:

To improve the decode speed and performance, enable (set to ‘on’) only those codes that are required by the application.

Keep in mind that some bar code types are only available when an internal imaging scanner is installed. All internal scanners can be configured using these dialog boxes. External, non-decoded scanners are also configured through the Scanner Properties dialog box. However, external decoded scanners must be configured by scanning special configuration bar codes. In these cases, the scanner manufacturer provides programming manuals for configuration purposes. • For Symbol decoded scanners, refer to the appropriate programming guide: • P300, or • LS3408. •

For Symbol non-decoded scanners, refer to: • LS3200 Programming Guide.

•

For Power Scan (PSC) decoded and non-decoded scanners, refer to: • Powerscan Programing Guide (PSC).

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

151

Page 178

Chapter 5: Configuration Non-Decoded Scanners

5.10.2 Non-Decoded Scanners

Figure 5.74 Non-Decoded Scanner Options • Tap on the Scanner dropdown menu, and choose Non-decoded. All the available bar code symbologies for this type of scanner can be selected in this tab. A ‘plus’ sign (+) to the left of the menu item indicates that a sub-menu of parameters is attached. •

Tap the stylus on the + sign to display the sub-menu.

•

To change a parameter value, double-tap on the parameter. If you need to type a value, a dialog box is displayed in which you can type a new value. If you need to change a yes or no value, double-tapping on the parameter toggles between yes and no.

If you’re using the keyboard: •

Highlight the bar code you want to work with, and press the <RIGHT> arrow key to display the sub-menu.

•

Use the <UP> and <DOWN> arrow keys to highlight a parameter.

•

To change a parameter value, press <SPACE> or the <RIGHT> arrow key. If a field requires text entry, a text box is displayed in which you can enter the appropriate value.

152 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 179

Chapter 5: Configuration Non-Decoded Options

5.10.2.1 Non-Decoded Options •

Tap the stylus on the + sign next to Options to display these parameters.

Dot Time (msec) The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 3000. A value of 0 (zero) disables the target dot.

Short Code When enabled, this parameter allows scanning of short I 2 of 5 bar codes (2 characters). When disabled, these short bar codes are rejected. Enabling “Short Code” may reduce the robustness of the decoding since the hand-held must decode more potential bar codes; it is therefore not recommended for general-purpose bar codes with 4 or more characters.

Verify The value entered for this parameter determines the number of correct additional decodes required after the initial decode, prior to a bar code being accepted. Higher values significantly increase the time it takes to decode a bar code but also improve the reliability of the decoded bar code.

Security This parameter controls the tolerance for decoding edge-to-edge bar codes (Code 93, Code 128, UPC/EAN). Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. The default value of 30 is generally a good compromise setting.

5.10.2.2 Code 39 Enabled Set this parameter to on to enable “Code 39” or off to disable it.

Full Ascii If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

153

Page 180

Chapter 5: Configuration Code 39

Include Check If this parameter is enabled, the check digit is included with the decoded bar code data.

AIAG Strip If this parameter is enabled, the AIAG data identifier is removed from each decoded Code 39 label. The data identifier occurs in the first position next to the Code 39 start character. It can be a single alphabetic character or a series of numeric digits followed by an alphabetic character. This identifier defines the general category or specific use of the data contained in the rest of the bar code. Note:

If your unit is operating with the Psion Teklogix TESS application, this parameter should not be used in conjunction with the TESS AIAG feature. This is because the hand-held performs the strip function before it processes the data through the AIAG feature; if the prefix is stripped, the data is not identified as AIAG.

Error Accept If the “Err Accept” and “AIAG Strip” parameters are enabled, all label data without an AIAG identifier character is accepted. If the “Err Accept” parameter is disabled and the “AIAG Strip” parameter is enabled, the label data is not accepted.

Mod Checks This parameter allows you to choose the check digit calculated: MOD 43 Check, MOD 10 Check or None. •

Double-tap on Mod Checks to display your options.

• Tap on a check digit to highlight it, and tap on OK. If you choose None, a check is not executed.

Field Size/Chars Field Size The field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.

154 Psion Teklogix 7535/7530 Hand-Held Computer User Manual