The text of a manual · part 18 of 48
7535/7530 Hand-Held Computer User Manual: Configuration 5, pages 161 to 170
Pages 161 to 170 of 440, from 7535/7530 Hand-Held Computer User Manual
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7530 and Teklogix 7535
Page 161
Chapter 5: Configuration Restoring A Profile
Performing The Backup
Figure 5.58 Performing The Backup •
Choose the Backup To \Flash or \Storage Card button to start the process, and create a profile.
5.7.2 Restoring A Profile To manually restore a profile: •
Choose Restore Selected Profile from the dropdown menu, and choose the Profile Name displayed in the drop down box.
Note:
You can also manually restore an auto restore profile located in flash or a storage device.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
135
Page 162
Chapter 5: Configuration IPv6 Support
5.8 IPv6 Support The IPv6 Support icon in the Control Panel allows you to activate IPv6 network support on your unit. This internet protocol specification (version 6) supports 128-bit IP addresses, replacing version 4.
Figure 5.59 IPv6 Support Icon •
Choose the IPv6 Support icon to display the associated dialog box.
Figure 5.60 IPv6 Support Tab •
Choose the checkbox next to Enable IPv6 Network Support to enable this internet protocol.
136 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 163
Chapter 5: Configuration Narrow Band Radio Setup, 7530 Only
5.9 Narrow Band Radio Setup, 7530 Only Keep in mind that the Narrow Band icon is only visible in the 7530 Control Panel when a Narrow Band radio is installed in the unit. Note too that this radio is not available for 7535 hand-helds. •
In the Control Panel, tap on the Narrow Band Radio icon.
5.9.1 Info Tab In the Narrow Band Radio dialog box, the Info tab displays information about the radio – it cannot be edited.
Figure 5.61 Narrow Band Information The Power information in this screen indicates the power of the radio installed in the unit – 0.5 or 1.0 W. The “Serial Number” is the identifier for the radio and is used by the protocol when the “Auto Radio Address” parameter is enabled. The “CIS Data” (Card Information Structure) is manufacturer information describing the PC Card installed in the 7535/7530. “DSP x.x / FPGA 0xNN” indicates the firmware revision of the radio’s DSP (x.x) and FPGA (0xNN) where x.x and NN represent actual revision numbers.
Statistics Screen •
Tap on the Statistics button to display the Protocol Statistics screen.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
137
Page 164
Chapter 5: Configuration Info Tab These statistics are updated every second while the dialog box is displayed.
Figure 5.62 Protocol Statistics The following table provides a brief description of these statistics:
Statistic cq
Description Channel quality. See the description of the “Channel Switch Speed” parameter in the channel tab for more information on how “cq” affects channel switching (see “Channel Switch Speed” on page 141).
ch
Current channel sc
Monitor state of RF Link: LOCKED=0, LOCKPENDING=1, LOWCQWAIT=2, SCANNING=3, STARTUP=4, ABANDON=5 rm
Number of received messages, complete application messages xm
Number of transmitted messages, complete application messages rf
Number of received polls with attached message xf
Number of transmitted frames ra
Number of received radio link aborts xi
Number of transmitted radio link initialization messages rp
Number of received polls xr
Number of transmitted retries pt
Number of poll timeouts xe
Number of transmitted errors rssi
Received Signal Strength Indicator
Table 5.1 Protocol Statistics Descriptions
138 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 165
Chapter 5: Configuration Info Tab
Low Level Screen •
Tap on the Low Level tab to display the Low Level statistics screen.
Figure 5.63 Low Level Statistics Screen Table 5.2 defines the elements of the Low Level statistics screen.
Statistic
Description
RxOk
Message buffers discarded due to lack of available receive buffers
RxHd
Message headers successfully received
RxBd
Message bodies successfully received
RxEr
Message buffers received with detected errors
RxOv
Number of transmitted messages, complete application messages
TxOk
Message buffers successfully transmitted
TxEr
Message buffers which failed to transmit
CD
Number of carrier detect changes detected
Coll
Number of collisions detected
Tx D
Actual difference in time (in RTC ticks) between when the most recent transmit (with timestamp) was scheduled to start and when it actually started.
TxMD
Maximum "Tx D" value
Rx X
Number of extra characters received for last received message (due to delay in host reporting back actual body size)
RxMx
Maximum "Rx X" value
MChg
Number of completed mode changes
Table 5.2 Low Level Statistics Descriptions
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
139
Page 166
Chapter 5: Configuration Channel Tab
Default All Parameters •
Tap on the Default all Parameters button to return all registry parameters to default values.
When this button is pressed, a screen appears asking if you’re sure you want to return all parameters to their default values. • Note:
Tap on the Yes button to return values to their default settings. This button does not default the radio parameters set under the Radio tab.
5.9.2 Channel Tab
Figure 5.64 Channel Tab
Channel Number This parameter determines the operating radio channel of the 7530 The allowable range for this parameter is 1 to 20. The default value is 1. Note:
The Channel Number dropdown menu displays only the channels that have been enabled in the Channel Enable List.
140 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 167
Chapter 5: Configuration Channel Tab
Power Up Channel When this parameter is enabled (checked), the 7530 begins communicating on the channel specified in the Channel Number parameter when the unit is powered up. This setting may prevent the migration of 7530s to the same channel due to uneven coverage in some sites. If this parameter is disabled (unchecked), the unit will continue communicating on the same channel that it was on before it was powered off.
Channel Enable List •
Tap on the Channel Enable List button to display a dialog box listing available channels.
Figure 5.65 Channel Enable Dialog Box This dialog box is completed by default with all channels that have frequencies configured. A checkmark indicates that a channel is enabled. An unchecked check box indicates that the channel is disabled. The maximum number of channels supported by the RA1001 Narrow Band radio is 20. Enabling a channel allows the channel to be set to an operating channel (Channel Number) and makes it available for channel searching. For example, if Channel 1 is the operating channel and all other channels are enabled, the 7530 can roam through all 20 channels.
Channel Switch Speed This parameter changes the threshold the 7530 uses to determine when communication quality with a base station is unacceptable. When this threshold is exceeded, the unit starts channel searching for a new base station. Setting this parameter to “Slow” means a higher threshold – the 7530 is more tolerant of poor communication quality. When the channel quality of the hand-held radio drops below 46%, the unit monitors the channel quality for 15 timeout periods Psion Teklogix 7535/7530 Hand-Held Computer User Manual
141
Page 168
Chapter 5: Configuration Channel Tab before searching for a new channel. If Channel Switch Speed is set to “Fast”, the current channel is only monitored for up to 2 time-out periods before channel switching begins. Important:
“Fast” switch speed is most effective where coverage areas are largely overlapping. If the coverage areas barely overlap, have dead spots, or if the 7530 frequently operates on the fringe of coverage, this parameter should be set to “Slow”.
Channel Selection Enabling “Manual Select” allows you to set the channel search order the 7530 will use if communication quality drops and channel switching is required. If this parameter is enabled, the 7530 uses the channel switching lists specified in the Manual Switch Table. If this parameter is disabled (unchecked), the hand-held uses a standard algorithm to decide which channel it should switch to in the event of poor channel quality. Warning:
It is not recommended that the “Manual Select” parameter be used without a clear understanding of how to order the channel sequences for optimum performance.
Manual Switch Table •
Tap on the Set Switch Table button to display the Manual Switch Table dialog box.
Figure 5.66 Manual Switch Table
142 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 169
Chapter 5: Configuration Channel Tab This feature is used rarely. It is used when the order of channel switching needs to be tightly controlled. The values in the “Channel” column are completed for you with the enabled channels when this dialog box is opened. For each corresponding enabled channel, the “List” column contains “0,0,0,0,0,0,0,0” values by default. If communication quality falls below 46%, only the channels entered in the Manual Switch Table are considered for channel switching. The channel search is carried out in the order in which the channels were entered in the table. To configure channel switching order for a particular channel: •
Highlight the channel you want to edit, and tap on the Edit Channel List button.
Editing The Channel List
Figure 5.67 Editing Channel List Only those channels that are enabled are displayed in the dropdown menus in the Edit Channel List dialog box. The allowable values range from 0 to 20. •
Tap on the arrow next to dropdown menu to scroll through the available channels. Highlight the value you want to assign.
•
Once you’ve assigned the switching order, tap on the OK button to close the dialog box.
The channel list is added to the selected channel in the Manual Switch Table dialog box.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
143
Page 170
Chapter 5: Configuration Protocol Tab
5.9.3 Protocol Tab
Figure 5.68 Protocol Tab
Enable Cellular Protocol The value assigned to this parameter must be identical to the value assigned to the corresponding parameter in the Psion Teklogix Network Controller, Wireless Gateway or Base Station. A warm reset of the 7530 is required before this parameter can take effect. If Enable Cellular Protocol is disabled (unchecked), the options in the Cellular Radio Address frame are displayed in grey text indicating that they cannot be accessed.
Cellular Radio Address Auto Radio Address If Auto radio address is enabled, the 7530 requests an automatically assigned radio address. Manual radio address is displayed in grey text indicating that it cannot be accessed.
Manual Radio Address The value entered in the Manual Radio Address parameter is used to identify the 7530 over the radio link. A unique value from 1 to 3840 must be assigned for each unit. Note:
This parameter is set to ‘0’ (an out-of-range value) by default to block radio communication when the unit is initially powered up. This prevents several new hand-helds from attempting to communicate with the same default terminal number at initial power up. Once the default value is changed, it cannot be set back to ‘0’.
144 Psion Teklogix 7535/7530 Hand-Held Computer User Manual