Page 211

Chapter 5: Configuration Postal: Japanese

5.10.5.9 Postal: Japanese Enabled Set this parameter to on to enable “Postal: Japanese”.

Field Size/Chars Refer to page 154 for details.

5.10.5.10 Postal: Korean Enabled Set this parameter to on to enable “Postal: Korean”.

Field Size/Chars Refer to page 154 for details.

5.10.5.11 Postal: PlaNET Enabled Set this parameter to on to enable “Postal: PlaNET”.

Field Size/Chars Refer to page 154 for details.

5.10.5.12 Postal: PostNET Enabled Set this parameter to on to enable “Postal: PostNET”.

Field Size/Chars Refer to page 154 for details.

5.10.5.13 Postal: Royal Enabled Set this parameter to on to enable “Postal: Royal”.

Field Size/Chars Refer to page 154 for details. Psion Teklogix 7535/7530 Hand-Held Computer User Manual

185

Page 212

Chapter 5: Configuration 2D DataMatrix

5.10.5.14 2D DataMatrix Enabled Set this parameter to on to enable “2D DataMatrix”.

Field Size/Chars Refer to page 154 for details.

5.10.5.15 2D Maxicode Enabled Set this parameter to on to enable “2D Maxicode”.

Field Size/Chars Refer to page 154 for details.

5.10.5.16 2D PDF-417 Enabled Set this parameter to on to enable “2D PDF-417”.

Field Size/Chars Refer to page 154 for details.

5.10.5.17 2D Micro PDF-417 Enabled Set this parameter to on to enable “2D Micro PDF-417”.

Field Size/Chars Refer to page 154 for details.

5.10.5.18 2D QR Code Enabled Set this parameter to on to enable “2D QR Code”.

Field Size/Chars Refer to page 154 for details. 186 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 213

Chapter 5: Configuration 2D RSS Code

5.10.5.19 2D RSS Code Enabled Set this parameter to on to enable “2D RSS Code”.

Field Size/Chars Refer to page 154 for details.

5.10.5.20 Aztec Enabled Set this parameter to on to enable “Aztec”.

Field Size/Chars Refer to page 154 for details.

5.10.5.21 Composite A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners.

Enabled Set this parameter to on to enable “Composite” bar code scanner. Important:

To successfully read this type of bar code, the two types of symbologies included in the composite must be enabled. In addition, “Center Bar Code Only” must be disabled.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

187

Page 214

Chapter 5: Configuration Decoded (External)

5.10.6 Decoded (External)

Figure 5.79 Tether And Console Port Settings While you cannot configure the scanner, you can configure communications with a serial decoded scanner using the options in this tab.

5.10.6.1 Tether Port

Figure 5.80 Tether Port Settings

188 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 215

Chapter 5: Configuration Tether Port

Baud Double-tapping on this parameter displays a pop-up window in which you can choose an appropriate baud rate.

Figure 5.81 Tether Port Baud Rates

Data Bits This parameter determines the number of bits for the data going through this port. Double-tapping on this option displays a pop-up window in which you can choose either 7 or 8 data bits.

Parity This parameter determines the type of parity checking used on the data going through the tether port. Double-tapping on this option displays a pop-up window in which you can choose the appropriate Parity.

Figure 5.82 Parity Settings

Stop Bits This parameter specifies the number of stop bits – 1, 1.5 or 2 – used for asynchronous communication.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

189

Page 216

Chapter 5: Configuration Console Port

5.10.6.2 Console Port

Figure 5.83 Console Port Settings

Enabled This parameter must be set to on in order for the 7535/7530 to recognize the device connected to the console port.

Baud Refer to page 189 for details.

Data Bits Refer to page 189 for details about this parameter.

Parity For details, refer to page 189.

Stop Bits Refer to page 189 for details about “Stop Bits”.

190 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 217

Chapter 5: Configuration Options Tab

5.10.7 Options Tab This tab allows you to tailor the double-click parameters and the display options associated with your scanner.

Figure 5.84 Options Tab

Double Click Parameters Click Time (msec) This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature. A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click Data” value rather than initiating a scan.

Click Data For both integrated and external scanners, this parameter determines which character is sent to the application installed in your 7535/7530 following a double-click. A dialog box appears, asking that you press the key you want to insert. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialog box resets the data to zero.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

191

Page 218

Chapter 5: Configuration Options Tab

Display Parameters Scan Result When this parameter is enabled, the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen.

Scan Indicator When this parameter is enabled, the laser warning logo appears on the display whenever the scanner is activated.

Scan Result Time (sec) The value assigned to the “Scan Result Time (sec)” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter. When you choose this option, a dialog box appears where you can enter a value. Note:

To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger.

Good Scan Beep And Bad Scan Beep These parameters determine whether or not the 7535/7530 emits an audible scanner ‘beep’ when a good (successful) scan or a bad (unsuccessful) scan is performed. Set these parameters to either on to enable the beeper or off to disable it.

Scan Log File If this parameter is enabled, the input barcode and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the ‘Scan Log File’ is enabled, there is a slight performance effect when performing multiple scans since the log file is written to persistent storage.

192 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 219

Chapter 5: Configuration Translations

5.10.8 Translations

Figure 5.85 Translation Tab •

In the Translation tab, choose the Add button.

Figure 5.86 Translation Dialog Box

Input This value is compared with the decoded bar code reading. If there is a match, the “Output” string is translated into the decoded bar code.

Output If there is a match between the decoded bar code and the corresponding “Input” string, the decoded bar code will be translated into the “Output” string. This string entry parameter can be null, or it may contain any combination of standard and special characters (e.g., function keys, <ENTER>, etc.). Psion Teklogix 7535/7530 Hand-Held Computer User Manual

193

Page 220

Chapter 5: Configuration SNMP (Simple Network Management Protocol) Setup

Type The value chosen from this dropdown menu determines what is compared with the decoded bar code reading – the beginning of decoded bar code, the end of decoded bar code, the entire decoded bar code or anywhere within the decoded bar code (default).

5.11 SNMP (Simple Network Management Protocol) Setup Simple Network Management Protocol (SNMP) is the protocol used to monitor and manage devices attached to a TCP/IP network (providing they support SNMP). SNMP uses Management Information Bases (MIBs) that define the variables an SNMP Network Management Station can access. Each product has a defined set of MIBs that determine how SNMP operates, the type of access allowed and so on. All Teklogix products support the TEKLOGIX-GENERIC-MIB – a MIB that defines some common features across Teklogix products. All devices also support MIB-II, a management information base that defines the common features of TCP/IP networks. The SNMP Agent software embedded in the 7535/7530 product supports SNMPv1 (RFC 1157). •

In the Control Panel, choose the SNMP icon.

Figure 5.87 SNMP Icon

194 Psion Teklogix 7535/7530 Hand-Held Computer User Manual