The text of a manual · part 6 of 14
WSS 1000 Product Reference Guide, pages 51 to 60
Pages 51 to 60 of 133
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WWC-1000, Symbol WWC-1010 and Symbol WWC-1040
Page 51
WSS 1000 Product Reference Guide
The WWC 1040 displays the message: ...updating config data and proceeds with the initialization which writes the configuration values to a R/W non-volatile section of radio flash memory.
Initiating Network Connection As the initialization continues, the wrist computer attempts to associate with the Spectrum24 AP using the default or newly entered Net Id.
WWC 1040 Association with AP Not Successful If the WWC 1040 is unable to associate with the AP (the Net Id is wrong or forgotten), it displays the message: STAT24 Ver 1.XX NOT Associated for a few seconds. A second message follows: Terminal cannot associate with AP. You’re out of range or not configured. Ctrl+C to end or other key to retry. Strike any key when ready.....
The WWC 1040 continues trying to connect until the attempt is cancelled. 1. Press <Ctrl + C> to end the attempt. The WWC 1040 displays the message: Halt Batch process Y/ N?
2. Type Y to exit to the DOS prompt (D:). 3. At the DOS prompt, type CFG24 and press <ENTER> to initiate the Configurator and display the Configurator screen. 4. Verify the Net Id with the LAN administrator to ensure you are entering the correct value. 5. Verify other parameters and proceed as directed in Initializing the WWC 1040 on page 4-3, beginning with step 4a.
4-10
Page 52
Spectrum24 RF Terminal Setup
WWC 1040 Association with AP Successful If the association is successful, the wrist computer begins operating using the software files loaded on the flash disk. On first initialization, you probably don’t have applications loaded. Proceed with loading the applications as directed in Installing Application Software on Flash Disk on page 4-11. On subsequent initializations, if only one application is loaded, that application is displayed automatically. If you loaded multiple applications, an application selection menu is displayed early in the initialization process. Select the application to load for the current session and proceed.
Installing Application Software on Flash Disk Note: LWP.HEX version 3.03 or greater is required on the WWC 1040 for this process. If you are not sure of the wrist computer’s hex version, boot (initialize) the WWC 1040. The hex version is displayed for approximately 5 seconds during the initialization process. Installing application software on the WWC 1040 flash disk includes downloading a HEX file to the WWC 1040, using SENDHEX on the PC and Program Loader on the wrist computer, and re-initializing the wrist computer. On the initial boot after a software download, the WWC copies the software files on to the flash disk, and remembers that the copy occurred, ensuring that it is not repeated each time the WWC is booted. The hardware required for performing the download includes: •
WWC 1040 wrist computer
•
CS 1000 1- or 4-slot cradle with power supply
•
DOS PC
•
RS-232 serial null modem cable.
Initiate Host Communications on the PC To update the hex image: 1. Power on the host PC. 2. On the host PC, change to the directory where the application’s hex file is stored and type the following command at a DOS prompt:
4-11
Page 53
WSS 1000 Product Reference Guide
SENDHEX <hexfile> 384 [1|2]<ENTER> where: SENDHEX is the command
<hexfile> is the hex file for the application being loaded. There may be other application hex files which load other software (e.g., STEP version 2.6.0 or greater, or TelNet Clients 3.0 or greater) to the flash disk. Note: Be sure to use applications that are flash-disk enabled.
38400 is the baud rate.
[1|2] sets the host communications port the cradle is attached to.
The following message is displayed: Press <ENTER> when remote is ready. ESC to abort...
3. Do NOT press <ENTER> yet. Set up the WWC 1040 as described in Initiate WWC 1040 Communications.
Initiate WWC 1040 Communications 1. Place the WWC 1040 in the cradle and power it off. 2. Boot the WWC 1040 to command mode. a. Press <ENTER> and <FUNC>. b. Press and release the Power button. c. Release <ENTER> and <FUNC>. The function selector screen displays: COMMAND MODE Select function Self Test
3. Scroll through Command Mode options using Ç or È#until “Program loader” is displayed. Press <ENTER>. 4. The WWC 1040 displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>
4-12
Page 54
Spectrum24 RF Terminal Setup
Note: To cancel this operation, press <CLEAR>. 5. Press <ENTER> to erase the EEPROM. When complete, the program prompts for the communications parameters. 6. Set the parameters to 38400 bps, 7 data bits, odd parity and no flow control. Press <ENTER>.
Start Communications 1. The WWC 1040 displays: Comm Parameters Start? <ENT>
2. Press <ENTER> on the WWC 1040. 3. The WWC 1040 displays: Comm Parameters Receiving:
If the host is not ready or if the cable is not connected properly between the host PC and the cradle, the WWC displays: Awaiting DSR
4. Press <ENTER> on the host PC to start the download. The wrist computer displays: Program loader Receiving: XXXX where XXXX indicates the download’s progress. 5. When the transmission is complete, the WWC 1040 displays: Program loader Status 0000
A status of 0000 (all zeros) indicates a successful transfer. If the status is other than 0000, check the cable connections between the host PC and the cradle and repeat the process. If the problem persists, contact the Symbol Support Center for assistance. 4-13
Page 55
WSS 1000 Product Reference Guide
6. After the download to each wrist computer is complete, re-initialize (cold boot) the WWC 1040 to finish copying the system files to the flash disk. Note: The WWC 1040 must be re-initialized to ensure the files are copied to the flash disk.
Updating System Software on Flash Disk To update the LWP hex image, load the new system files on the flash disk using the SENDHEX utility on a PC. This update can be performed on multiple wrist computers in a cradle at one time, with each wrist computer running Program Loader from Command Mode. Note: The WWC 1040 is shipped with the LWP hex file installed. Use this procedure ONLY: • to load a new version of LWP greater than 3.03 • if you experience serious difficulties • if you are so directed by Symbol’s Technical Support staff. 1. Following the instructions for installing software on the flash disk (through step 5). Be sure, when entering the SENDHEX command on the PC, to issue the command from the directory where the hex file (LWP.HEX) is stored. When the download is complete, the WWC 1040 displays the following query: LWP.HEX Ver X.XX Loading system files 1. Reformat flash 2. Use flash as-is Select [1,2]:
Note: Reformatting the flash removes all files stored on the flash disk. 2. Select 1, Reformat flash, ONLY if you have problems with the WWC 1040’s operation.
4-14
Page 56
Spectrum24 RF Terminal Setup
Caution This removes the system software and all applications! Select 2, Use flash as-is, to update the flash while retaining the existing contents. 3. If you select 1, the WWC displays the message: Are You sure Y or N
4. Press Y to continue with the reformat or N to cancel and press <ENTER>. The WWC 1040 finishes reformatting (if requested), copies the files to the flash disk, and executes them.
Multiple Applications on the Same Wrist Computer The system files (from LWP.HEX) fill over 200 KB of the flash disk’s 1 MB. Current standard applications such as STEP or TN clients require between 100 KB and 150 KB of flash disk. This leaves ample space for installing more than one application on a single WWC 1040. Wrist computers have been configured to run as many as four applications, with a maximum of five applications allowed. Individual applications may require special configurations that can only be set at boot time, such as RAM disk size. The TN clients require configuring a minimum-size RAM disk (<100 KB) because their limiting resource is program execution space. STEP, on the other hand, uses the RAM disk to hold forms. Some STEP application implementations use forms extensively and require a larger RAM disk (>100 KB). The application loaded last defines the size of the RAM Disk for all applications on the flash disk. Note: The system files contained in the LWP.HEX have the RAM disk defined as 80 KB.
Note: It is possible with multiple applications to have applications coexisting on the wrist computer with conflicting memory requirements. If this occurs, work out a compromise value that both applications can work with before loading the files. If multiple applications are installed on the WWC 1040, a menu is presented during the initialization process where you select the application to run for this session. Switching
4-15
Page 57
WSS 1000 Product Reference Guide between applications requires re-initializing the wrist computer and selecting an alternative application when prompted. On warm boots, the wrist computer re-initializes and re-enters the same application that was selected before the re-initialization. On cold boots, if there are multiple applications available, an application selection menu is presented.
4-16
Page 58
Chapter 5 Assembling the WSS 1000 System The WSS 1000 assembly consists of the WWC 1000 and mount together with a scanning component, the RS 1 ring scanner, or WS 1200 back-of-hand scanner.
Assembling the WWC 1000 (Standard Unit) 1. Orient the cable on the WWC 1000 for right or left-handed operation. 2. Ensure that the cable is fully seated in the channel.
Channel Channel
Figure 5-1. Orienting the Cable on the WWC 1000
5-1
Page 59
WSS 1000 Product Reference Guide
3. Place the WWC 1000 wrist computer onto the wrist mount, facing you. Be sure the mount is oriented so that the longer strap will be further up the forearm. 4. Snap the bar over the WWC 1000 using the snaps on either side of the mount. The straight part of the bar lies across the front of the WWC 1000, with the curved part in back.
Figure 5-2. Snapping the Bar Over the WWC 1000 Note: The snaps on the wrist mount act as a tear-away device allowing the wrist computer to detach from the mount if it catches on an object.
5-2
Page 60
Operating the WSS 1000
Assembling the WWC 1000 (Rugged Boot Option) When using the WSS 1000 in harsher conditions, a rugged boot mount may be ordered. To assemble the WWC 1000 with the rugged boot: 1. Orient the cable on the WWC 1000 for right or left-handed operation. 2. Ensure that the cable is fully seated in the channel (Figure 5-1). 3. Orient the WWC 1000 so that the longer strap will be further up the forearm and the keyboard is facing you. If necessary, rotate the protective sleeve attached to the mount to accomplish this.
Figure 5-3. Rotating Protective Sleeve on Mount
5-3