The text of a manual · part 5 of 14
WSS 1000 Product Reference Guide, pages 41 to 50
Pages 41 to 50 of 133
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WWC-1000, Symbol WWC-1010 and Symbol WWC-1040
Page 41
WSS 1000 Product Reference Guide
If the host is not ready or the cable is not connected between the host PC and cradle, the wrist computer displays: Awaiting DSR
2. Press <ENTER> on the host computer. SENDHEX begins transmitting the program image. When communications are established, the WWC 1000 displays: Program loader Receiving: XXXX where XXXX is the program segment address being transferred. 3. When the transmission is complete, the WWC 1000 displays: Program loader Status 0000
A status of 0000 (all zeros) indicates a successful transfer. Other status values indicate an error. These values are provided in Appendix C.
Ending Communications To return to the Command Mode main menu: 1. Press <CLEAR> on the WWC 1000. 2. Power down the WWC 1000. 3. Remove the WWC 1000 from the cradle. 4. Reboot the WWC 1000 using the appropriate cold boot sequence described in Booting the WWC 1000 on page 6-3.
3-6
Page 42
Chapter 4 Spectrum24® RF Terminal Setup Spectrum24 Terminals In Spectrum24 terminals, wireless connectivity is accomplished using standard communications protocols. Because they are standard, the protocols are generalized and take up considerably more space on the wrist computer’s NVM than was required for Spectrum One® wrist computers. Because there is less space available in NVM for application files, the WWC 1040 operates with an additional megabyte of non-volatile memory or flash disk. This extra memory reduces not only the boot times but also the time and resources required to load applications into the wrist computer. The flash disk also offers the possibility of running multiple applications from the same WWC 1040 (see Multiple Applications on the Same Wrist Computer on page 4-15 for more information). With version 3.03 or later of the system software (LWP.HEX), the WWC 1040 can also run diagnostic tools.
Accessing the Flash Disk The flash disk is accessed through a driver, FLASHDSK.SYS, which makes the flash disk appear to a program as another disk drive (E:). The drive has characteristics of fast reading but slow writing (e.g., even for the smallest files, the write process takes 3 to 4 seconds), which make it ideal for files that are written once, accessed often, and seldom updated. We recommend that you use the flash disk (E:) mainly for application and configuration file storage. It is important to note that because of the slow writing time (3 to 4 seconds), writing files during a power interruption (low battery, dead battery, suspend, power off, or power failure) could corrupt the disk. Be sure to only write data to the disk with the wrist computer connected to external power or with the battery fully charged to avoid problems. To avoid overwriting the flash disk by mistake, the flash disk is set to read-only mode for normal operation.
4-1
Page 43
WSS 1000 Product Reference Guide
Standard Spectrum24 Software The WWC 1040 comes with the system software installed, including: •
Spectrum24 radio drivers
•
TCP/IP software
•
Configuration files
•
Various utilities.
A BIOS of version 1.09 or later is required. The default files cover most expected installations/initializations with minor changes as detailed in this chapter. If your requirements are more advanced, refer to the Spectrum24 Network Development Kit documentation for more information on the Spectrum24 RF network, SLAODI.COM, the Symbol-provided ODI driver, and the configuration file setups required for various platforms.
Boot Options & Internet Addressing Each WWC 1040 requires a unique internet address (IP address), allowing messages it sends and receives to be correctly routed over networks conforming to the TCP/IP protocol standards. These addresses can be administered and entered manually, or administered and allocated by a server on the network. By default, the WWC 1040 uses NOBOOT (manual entry) to define the IP address. To set the IP address, use the CFG24 utility described in Initializing the WWC 1040 on page 4-3. Two protocols are defined for the IP address allocation on the network: BOOTP and DHCP. To allocate IP addresses through BOOTP or DHCP, change the boot option in the configurator using the Boot Mode parameter.
4-2
Page 44
Spectrum24 RF Terminal Setup
Initializing the WWC 1040 Note: This section covers specific settings required on first booting the WWC 1040, out of the box. For a complete review of the CFG24 screens, refer to Appendix C, Spectrum24 Network and Flash Disk Utilities. To initialize a WWC 1040 which has LWP.HEX version 3.03 or greater loaded: 1. Insert a charged battery in the WWC 1040. Refer to Chapter 2, Cradle Setup and Battery Charging for instructions on charging and installing a battery. 2. Cold boot the WWC 1040. a. Press <Æ + ENTER>. b. Press and release the Power button. c. Release <Æ + ENTER>. 3. The WWC 1040 loads software, then displays the Spectrum24 Configurator (CFG24) menu, shown in Figure 4-1. Note: On subsequent initializations, type CFG24 at the DOS prompt to bring up the configurator. CONFIGURATOR 1.XX View config params Net Id Subnet Mask Default Router Terminal IP Address Diversity Terminal Sleep Mode Boot Mode
Figure 4-1. CFG24 Main Menu
4-3
Page 45
WSS 1000 Product Reference Guide
On the WWC 1040 screen, the top and bottom lines of the menu are displayed, and the remaining lines are viewed by scrolling. In this menu, pressing <CLEAR> has the same effect as selecting Exit. 4. The WWC 1040 initially is set to NOBOOT mode. To configure the wrist computer for operation, set up the parameters provided in Table 4-1 (the procedures are detailed in the steps that follow). Table 4-1. Spectrum24 Configuration Parameters
4-4
Net Id
The Net Id identifies the radio network and differentiates between different radio networks. All equipment on one network must use the same Net Id. Set to the same value specified for the Spectrum24 Access Points (APs).
Boot Mode
The boot mode indicates the source of the wrist computer’s IP address. If this value is set to “Manual entry”, you must enter a wrist computer IP address through CFG24.
Terminal IP Address
Required if you are not using a boot server to allocate IP addresses (BOOTP or DHCP). Set as advised by your LAN administrator. Note: Take care entering this value! The IP address must be unique in the network or communications will be unpredictable.
Subnet Mask
Set as advised by your LAN administrator. Note: If you change boot mode, the value set by a server overrides this value.
Default Router
The default router is the address of the node where all packets destined for remote networks will be sent. Set as advised by your LAN administrator. Note: If you change boot mode, the value set by a server overrides this value.
Diversity
Determines whether the radio firmware attempts to use one or two antenna ports for communications. It is important to match this setting with the actual number of antennas in use. If set to “Yes”, the radio firmware attempts to use both antenna ports for communications. The WWC 1040 has one antenna. Set to “No”.
Page 46
Spectrum24 RF Terminal Setup
Table 4-1. Spectrum24 Configuration Parameters (Continued) Terminal Sleep Mode
Determines whether radio is powered off after the wrist computer enters sleep mode due to inactivity. Refer to Appendix D for more information. The default value is “On”.
Power Management
If power management is set to PSP, the radio powers up only when there is traffic on the network. If it is set to CAM, the radio is always ready to receive. Use the PSP setting to save battery life. The default value is “PSP”.
a. To view the WWC 1040’s default parameters, select VIEW CONFIG PARAMS (Figure 4-2). This screen is for display only; it is not a data entry screen. Use it to review the wrist computer’s IEEE (or MAC) address, IP address, and Net Id. Press <CLEAR> or <ENTER> to return to the main menu. VIEW CONFIG PARAMS Terminal IEEE addr 00:a0:f8:00:02:b8 Terminal IP Address 157.235.93.186 Net Id = 150 ÇÈ, Clear, Enter
Figure 4-2. View Configuration Parameters Screen
4-5
Page 47
WSS 1000 Product Reference Guide b. To change the Net Id, select Net Id from the CFG24 Menu. The Net Id screen is displayed. NET ID Enter Net Id(hex): 150
BkSp, Clear, Enter
Figure 4-3. Net Id Screen To change the current Net Id value, backspace over the current value and type a new value, in hexadecimal format, in the range 101 to 1FE. Alphabetical hex values can appear in upper or lower case. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. c. Select Subnet Mask from the main configuration menu. The Subnet Mask screen is displayed. SUBNET MASK Enter Subnet Mask: 255.255.255.0
Bksp, Clear, Enter
Figure 4-4. Subnet Mask Screen To change the current Subnet Mask setting, backspace over the current value and type a new value, in decimal form. Each part of the four-part address must be in the range 0 to 255. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-6
Page 48
Spectrum24 RF Terminal Setup d. Select Default Router from the main configuration menu. The Default Router screen is displayed. DEFAULT ROUTER Enter Default Router 157.235.93.178
BkSp, Clear, Enter
Figure 4-5. Default Router Screen To change the current Default Router setting, backspace over the current value and type a new value, in decimal form. Each part of the four-part address must be in the range 0 to 255. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. e. Select Terminal IP Address from the main configuration menu. The Terminal IP Address screen is displayed. TERMINAL IP ADDRESS Enter IP address: 157.235.93.186
BkSp, Clear, Enter
Figure 4-6. Terminal IP Address Screen To change the current Terminal IP Address, backspace over the current value and type a new value in decimal form. Each part of the four-part address must be in the range 0 to 255. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-7
Page 49
WSS 1000 Product Reference Guide f. Select Diversity from the main configuration menu. The Diversity screen is displayed. DIVERSITY 2 antennas (Yes/No) Yes
ÇÈ,#Clear, Enter
Figure 4-7. Diversity Screen To change the current Diversity setting, use the ÇÈcursor keys to toggle between the settings “Yes” and “No”. For the WWC 1040, set Diversity to “No”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. g. Select Terminal Sleep Mode from the main configuration menu. The Terminal Sleep Mode screen is displayed. TERMINAL SLEEP MODE Radio state: On
ÇÈ,#Clear, Enter
Figure 4-8. Terminal Sleep Mode Screen To change the current Terminal Sleep Mode, use the ÇÈ cursor keys to toggle between the “On” and “Off” settings. The default setting is “On”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-8
Page 50
Spectrum24 RF Terminal Setup h. Select Boot Mode from the main configuration menu. The Boot Mode screen is displayed. BOOT MODE IP address from: Manual entry
ÇÈ,#Clear, Enter
Figure 4-9. Boot Mode Screen To change the current boot mode, use the ÇÈ#keys to toggle among the three settings: “Manual entry”, “BOOTP”, and “DHCP”. Refer to Appendix C, Spectrum24 Network and Flash Disk Utilities for a complete explanation of the three boot modes. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. i. Select Power Management from the main configuration menu. The Power Management screen is displayed. POWER MANAGEMENT Radio Power Mode PSP
ÇÈ,#Clear, Enter
Figure 4-10. Power Management Screen To change the current power management mode, use the ÇÈ#keys to toggle between the settings “PSP” and “CAM”. The default setting is “PSP”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. 5. When all of your changes are made, press <CLEAR> to return to the main configuration menu. 6. Select Exit from the main configuration menu and press <ENTER> to exit the configurator.
4-9