The text of a manual · part 4 of 14

WSS 1000 Product Reference Guide, pages 31 to 40

Pages 31 to 40 of 133

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol WWC-1000, Symbol WWC-1010 and Symbol WWC-1040

Page 31

WSS 1000 Product Reference Guide

When to Replace or Recharge Batteries The WSS 1000 provides two types of indicators to notify you when battery power is running low: warning messages and modified cursors. These indicators may be changed or disabled by an application. •

LOW POWER - When the battery is low, the cursor changes as shown in Table 2-1. Depending on the configuration (if ERR3000 is loaded), the message LOW BATTERY is also displayed. At this level, the wrist computer continues to operate, but there is probably less than 1 hour of usable power left.

•

VERY LOW - When the power is very low, the DEAD BATTERY message is displayed and the system powers off. Replace or recharge the battery before attempting to use the wrist computer. If the battery is not immediately recharged or replaced, data may be lost.

Table 2-1. Cursor Indicators Keyboard State

Cursor Character

Unshifted

∨

Shifted

∧

Control c

Alt a

Function Right Left f

Low Battery c a a f

R L

The characters shown do not exactly match what will appear on your wrist computer’s screen.

2-6

Page 32

Cradle Setup

Supercap Power Backup The wrist computer has a supercap power backup to prevent data loss during battery replacement. The supercap backup provides sufficient power to preserve memory contents for approximately 15 minutes while the batteries are replaced. Note: The supercap does not provide enough power to operate the wrist computer. Replace or recharge the primary batteries immediately upon receiving a dead battery message.

Replacing Batteries To replace the Lithium-Ion battery pack (Symbol p/n 20-16228-02): 1. Power off the wrist computer. 2. Unlock and remove the battery compartment door. 3. Remove the spent battery pack. 4. Insert a fully-charged battery pack in the compartment. 5. Replace and lock the battery compartment cover.

Figure 2-5. Battery Compartment

2-7

Page 33

WSS 1000 Product Reference Guide

Battery Charging Charging the Wrist Computer’s Battery To charge a Lithium-Ion battery in the CS 1000 Single-Slot or 4-Slot Cradle: 1. Verify that the cradle has power. 2. Slide the WWC 1000 in the cradle as shown in Figure 2-6 . 3. The WWC 1000’s battery begins charging automatically. The battery pack fully charges in approximately 120 minutes.

Figure 2-6. Inserting Wrist Computer into 4-Slot Cradle

Charging the Spare (Auxiliary) Battery in the Single-Slot or 4-Slot Cradle 1. Verify that the cradle has power.

2-8

Page 34

Cradle Setup

2. Lift the latch on the spare battery, and insert the battery in the cradle’s charging slot. The latch snaps into place when the battery is inserted.

Figure 2-7. Inserting Spare Battery in Cradle 3. The spare battery is charged in approximately two hours, even if the WWC 1000 is charging at the same time.

Battery Charging Tips For maximum capacity and battery life: •

Charge at a temperature between 0oC and 45oC (32oF and 113oF).

•

Recharge as soon as you see the “Dead Battery” message.

•

Charge Lithium-Ion batteries after storage.

2-9

Page 35

WSS 1000 Product Reference Guide

2-10

Page 36

Chapter 3 Batch and Spectrum One Initialization Communications For wrist computers used in a direct communications (batch) environment or a Spectrum One network environment, applications are transferred from a host computer over a communications line to the wrist computer. This procedure uses the SENDHEX program on the host computer and the Program Loader function (from Command Mode) on the WWC 1000. Programs are stored in the wrist computer’s nonvolatile memory (NVM), also called the application EEPROM. Note: For details on SENDHEX, refer to the Series 3000 Application Programmer's Manual. Other software may be used in place of SENDHEX.

3-1

Page 37

WSS 1000 Product Reference Guide

Set up for Initialization 1. Verify that the cradle is connected to the host PC. Refer to Chapter 2, Cradle Setup and Battery Charging. 2. Place the WWC 1000 in the cradle and power it off.

Figure 3-1. Placing the WWC 1000 in the Cradle

Loading an Application Note: To cancel communications at any time during the session, press CLEAR on the WWC 1000. The session stops immediately. To download an application, initiate the communications software on the host computer and WWC 1000. The WWC 1000 must be connected to the host through a cradle to program the EEPROM. Note: Communication parameters specified on host and WWC 1000 must match. These parameters typically are: 38400 bps 7 bit data Odd parity None

3-2

Page 38

Batch and Spectrum One Initialization

Initiate Host Communications Software on the PC 1. Power on the host computer. 2. Start the communication program. 3. At a DOS prompt, enter the SENDHEX command: sendhex pgmname 38400 com2 where: SENDHEX is the command.

pgmname is the application being loaded (.hex extension is optional).

parameters are the communications parameters following the program name. Parameters include baud rate, communications port, data bits, parity, and flow control. To accept the default parameters, do not enter a value.

In the example, baud rate is set to 38400 bps and communications port to COM2. The default values are accepted for the remaining parameters. Note: Versions of SENDHEX earlier than 3.0 do not support flow control. If you use an earlier version and encounter communication errors, use a lower baud rate. If you use a later version of SENDHEX and have communications errors, try setting flow control to XON/XOFF. 4. SENDHEX displays the prompt: Press <ENTER> to begin communications.

5. Do NOT press <ENTER> yet. Before starting communications (refer to Starting Communications on page 3-5), set up the WWC 1000 for loading an application as directed in the following section.

Initiate WWC 1000 Communications To prepare to load an application onto the WWC 1000: 1. Boot the WWC 1000 to command mode. a. Press <ENTER> and <FUNC>. b. Press and release the Power button.

3-3

Page 39

WSS 1000 Product Reference Guide c. Release <ENTER> and <FUNC>. The function selector screen displays: COMMAND MODE Select function Self Test

2. Scroll through the Command Mode options using UpArrow or DownArrow until "Program loader" displays. Press <ENTER>. 3. The WWC 1000 displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>

Before loading the new application, erase NVM’s original contents. Note: To cancel this operation, press <CLEAR>. 4. Press <ENTER> to erase the EEPROM. When complete, the program prompts for the communications parameters. 5. Baud Rate.The WWC 1000 displays: Comm Parameters Baud 5

38400

Scroll through the list using UpArrow or DownArrow. When the correct rate is displayed (38400 is recommended), press <ENTER>. 6. Data Bits. The WWC 1000 displays: Comm Parameters Data Bits 7

Press <7> (recommended) or <8> to specify data bits, or scroll through the list using UpArrow and DownArrow. Press <ENTER> when the correct value is displayed.

3-4

Page 40

Batch and Spectrum One Initialization

Note: If 8 data bits is selected, the program selects "No parity" and skips the next step. 7. Parity. If 7 data bits is selected, the WWC 1000 displays: Comm Parameters Parity Odd

Press the first letter of a parity option (Even, Odd, None, Space, or Mark), or scroll using UpArrow and DownArrow and press <ENTER> when the correct value is displayed. 8. Flow Control. The WWC 1000 displays: Comm Parameters Flow Control None

Press the first letter of a flow control option (None, Xon/Xoff, or RTS/CTS), or scroll using UpArrow or DownArrow and press <ENTER> when the correct value is displayed. 9. Go to Starting Communications to continue.

Starting Communications The WWC 1000 is ready to receive the program from the host PC and displays: Comm Parameters Start? <ENT>

1. Press <ENTER> on the WWC 1000. The WWC 1000 waits a few seconds for the host PC to initiate communications. While waiting, the WWC 1000 displays: Comm Parameters Receiving:

3-5