The text of a manual · part 3 of 14
WSS 1000 Product Reference Guide, pages 21 to 30
Pages 21 to 30 of 133
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WWC-1000, Symbol WWC-1010 and Symbol WWC-1040
Page 21
WSS 1000 Product Reference Guide
WS 1200 Scanner Scan LED
Scanner Connector Scan Window Front/Top View
Trigger Connector
Back View Protective Cap
Trigger Cable Scan Button
Interface Cable
Back View with Cables WS 1200 Mount
Component Descriptions Wrist Computer Detaches from scanner and provides for minimum breakaway force as safety feature. Controls scanner (e.g., laser power on, visual feedback, scanner connectivity), receives data from scanner, and transmits data via batch or radio communications. Includes interconnect cable.
Wrist Mount Worn on wrist or forearm of either arm. Detaches from wrist computer, which can then be used by other operators wearing their own wrist mounts.
RS 1 Ring Scanner Miniature laser bar code scanner, with trigger on thumb side of mount. Visual feedback for operator is provided through a 2-color LED on the back of the ring scanner. 1-4
Page 22
The WSS 1000 System
RS 1 Ring Mount Worn on either hand using a strap which wraps around both the index and middle fingers, preventing the scanner from rotating on the finger during use. Detaches from ring scanner, which then can be used by other operators wearing their own ring mounts.
WS 1200 Scanner Laser scanner worn on back of hand, with thumb-activated cabled trigger. Scan LED on top of scanner provides operator feedback.
WS 1200 Mount Worn on either hand and includes “o-rings” to insert fingers to secure mount. Detaches from WS 1200.
Keyboard 27-key keypad with alphanumeric and function keys. Left and right shift keys provide the equivalent of a 56-key keyboard.
Lithium-Ion Battery Pack User-replaceable 1300 mA Lithium-Ion battery pack, supporting a typical 8-hour work shift at 0 - 50° C. The pack powers both wrist computer and scanner and operates through a maximum of 500 full recharge cycles. The battery can be recharged using a CS 1000 cradle or a Universal Battery Charger with adapter.
1-5
Page 23
WSS 1000 Product Reference Guide
Radio and Network Options Spectrum One Network The WWC 1010 includes an internal radio frequency transmitter/receiver for use in a Symbol Spectrum One network.
Spectrum24 Network The WWC 1040 includes an internal radio frequency transmitter/receiver for use in a Symbol Spectrum24 network.
Accessories The following accessories are available for the WSS 1000 System.
Attachments A rugged boot (p/n 21-19670-02) provides added protection for the wrist computer, and is used in place of the snap-on bar on the wrist mount. The WS 1200 is equipped with a protective cap.
Cradles The CS 1000 single-slot and 4-slot cradles function as both a communications device and a battery charger, and are the fastest means of charging the battery. The cradle is table-top or wall-mounted.
UBC 1000 (Universal Battery Charger) and Adapter This 4-battery charger is either desk-mounted or wall-mounted. •
UBC1000-400D (Desk Mount)
•
UBC1000-400W (Wall Mount)
•
Battery adaptor for WWC 1000 using UBC 1000 (p/n 50-12100-234).
1-6
Page 24
The WSS 1000 System
Power Supply The following power supplies are available with the CS 1000 cradle: p/n 50-14000-045
Powers one single-slot cradle p/n 50-14000-052
Powers one 4-slot cradle p/n 50-14000-055
Powers four 4-slot cradles p/n 25-16657-01
Adapter cable (used with four-cradle power supply).
Before You Use the WSS 1000 System Before using the WSS 1000 system for the first time, perform the following procedures:
Install and Charge the Battery Charge the Lithium-Ion battery. The battery can be charged while in the wrist computer or separately in the cradle’s charging slot. Refer to Chapter 2 for instructions on installing the cradle and charging the battery.
Load the Appropriate Software Initialize the WWC 1000 by loading the system software and applications. For batch applications or a Spectrum One network environment (1000 or 1010), refer to Chapter 3 for information on loading the software. For a Spectrum24 network environment (1040), refer to Chapter 4.
1-7
Page 25
WSS 1000 Product Reference Guide
1-8
Page 26
Chapter 2 Cradle Setup and Battery Charging Mounting the CS 1000 Cradle The CS 1000 Single-Slot and 4-Slot Cradles may be mounted on a tabletop or wall mounted.
Table-Top Mounting The CS 1000 Single-Slot Cradle has a rear handle for desktop mounting. To mount the CS 1000 4-Slot Cradle on the table top: 1. Place the mounting stand on a flat surface. 2. Place the cradle onto the stand so that the holes in the bottom of the cradle align with the bottom leg of the stand. The cradle should be tipped back at a slight angle. 3. Use two #6 screws (3/4” max. length) to secure the top of the cradle to the top of the stand.
Wall Mounting To make the connection process easier, connect the power supply to the cradle before mounting.
Single-Slot An optional metal bracket is available from Symbol as part of a kit for mounting the singleslot cradle to a wall. Contact a Symbol sales representative to order.
2-1
Page 27
WSS 1000 Product Reference Guide
Four-Slot To wall mount the CS 1000 4-Slot Cradle: 1. Place the empty cradle on the wall where it is to be mounted. 2. Insert two #8 screws through the holes in the outer spare battery compartments (Figure 2-1). 3. Insert two more screws through the holes on the lower portion of the cradle (between the first and second slot, and between the third and fourth slot). Insert first
Insert second
Figure 2-1. Wall Mounting the 4-Slot Cradle
2-2
Page 28
Cradle Setup
Connecting the Host and CS 1000 4-Slot Cradle To connect the CS 1000 4-Slot Cradle to a host computer for communications: 1. Plug the RS-232 serial cable’s DB-25 connector in the cradle’s communication port. The port is located on the back right-hand side of the single-slot cradle, and on the left side of the 4-slot cradle.
One Slot
Four-Slot
Figure 2-2. Plugging Serial Connector into Single-Slot and 4-Slot Cradles 2. Connect the cable’s other DB-25 connector to the host’s serial (COMM) port. 3. Connect the power supply cord’s round connector to the cradle’s power port (Figure 2-3). The single-slot cradle’s power port is on the back right-hand side, above the communications port; use power supply p/n 50-14000-045.
2-3
Page 29
WSS 1000 Product Reference Guide
The four-slot cradle’s power port is in the center back; use power supply p/n 50-14000-052.
Single-Slot
Four-Slot
Figure 2-3. Plugging Power Supply into Single-Slot and 4-Slot Cradles 4. Connect an adapter cable to the other end of the power supply.
Figure 2-4. Plugging Power Supply into Adapter Cable 5. Plug the adapter cable into an electrical outlet.
2-4
Page 30
Cradle Setup
Connecting to Other Cradles Up to 24 four-slot cradles can be daisy-chained together using the RS-232 inter-cradle cable (p/n 25-16740-01). Note: Single-slot cradles cannot be interconnected.
Caution Each cradle must receive power directly from a compatible power supply; any other method of power hookup is unsafe. 1. Plug one end of the inter-cradle cable into the cradle’s communication port located on the right side of the first cradle. 2. Plug the inter-cradle cable’s other DB-25 connector into the second cradle’s communication port, located on the left side. 3. Connect a power supply to the second cradle as described in the previous sections. 4. Repeat the above steps for any additional cradles you wish to connect.
Battery Charging The WSS 1000’s primary power is provided by a 1200 mAh Lithium-Ion battery pack.
Battery Life The approximate life of the battery pack between charges is a typical 8-hour shift @ 500 scans per hour. This time, however, is affected by many factors, including temperature, battery age, application, and data collection method. The following uses and operating conditions place a burden on the battery and shorten the battery’s life: •
Scanning
•
Radio communications
•
Very high operating temperatures
•
Very low operating temperatures.
The WSS 1000 powers down during periods of non-use, and powers on when scanning activity resumes (under application control).
2-5