Page 61
WSS 1000 Product Reference Guide
4. Place the WWC 1000 wrist computer onto the wrist mount by sliding it into the protective sleeve.
Figure 5-4. Sliding WWC 1000 into Sleeve 5. Snap the mount straps onto the WWC 1000 to secure.
Figure 5-5. Snapping Mount Straps on the WWC 1000
5-4
Page 62
Operating the WSS 1000
Assembling the Ring Scanner 1. Adjust the strap of the ring mount to fit your right or left index and middle fingers: a. Slip the mount onto your right or left index and middle fingers, oriented so the trigger is next to your thumb.
Figure 5-6. Placing the Ring Mount on Fingers b. If necessary, adjust the strap so that the mount fits comfortably.
Figure 5-7. Adjusting Strap c. Remove the mount. 2. Insert the ring scanner in the ring mount, depending on right or left-handed use. a. Determine whether the scanner will be used on a right or left arm. b. Orient the ring scanner to the mount so that the trigger is next to the your thumb.
5-5
Page 63
WSS 1000 Product Reference Guide c. Slide the ring scanner backwards into the mount.
Figure 5-8. Sliding the Ring Scanner into the Mount 3. Plug the cable connector from the WWC 1000 in the interface port on the back of the ring scanner, with the arrow on the top of the cable facing up.
Figure 5-9. Connecting Cable from WWC 1000 to Ring Scanner
5-6
Page 64
Operating the WSS 1000
Wearing the WSS 1000 System with the Ring Scanner To assemble the WSS 1000 system with the ring scanner on your arm and hand: 1. Slide the wrist mount on your arm, so that the longer strap is further up your arm.
Figure 5-10. Sliding Wrist Mount Onto Arm 2. Pull the straps through the buckles so the mount is secure but not tight.
Figure 5-11. Adjusting Straps on Wrist Mount 3. Use the Velcro to secure the straps.
5-7
Page 65
WSS 1000 Product Reference Guide
4. Slide the ring mount and ring scanner on your right or left index and middle fingers with the trigger next to your thumb.
Figure 5-12. Sliding Ring Mount and Scanner Onto Finger
Removing the Ring Scanner To remove the ring scanner for use by another operator: 1. Remove the cable from the scanner’s interface port by snapping the connector out to the side. 2. Press the mount release button and gently pull/push the ring scanner out of the mount. Mount Release Button
Figure 5-13. Removing the Ring Scanner from the Mount
5-8
Page 66
Operating the WSS 1000
Assembling the WS 1200 Scanner The WS 1200’s mount can be used by both right and left-handed users. Note: Verify that the WSS 1000 has the correct data cable, shown below, for use with the WS 1200 scanner.
Figure 5-14. WS 1200 Data Cable 1. Assemble the WWC 1000 wrist computer in the mount as directed in Assembling the WWC 1000 (Standard Unit) on page 5-1. 2. Plug the trigger cable in the scan port on the back of the scanner. Scan Port
Figure 5-15. Inserting Trigger Cable 3. Plug the data cable from the WWC 1000 in the interface port on the back of the WS 1200 scanner. The data cable connector is molded to fit next to the trigger cable connector. Trigger Cable
Interface Port
Figure 5-16. Inserting Data Cable 4. Place the WS 1200 on the mount, securing with the velcro.
5-9
Page 67
WSS 1000 Product Reference Guide
Figure 5-17. Placing WS 1200 onto Mount
Wearing the WSS 1000 System with the WS 1200 Scanner 1. Slip the WS 1200 mount’s strap through the buckle as shown below to create a loose loop.
Strap Buckle
Figure 5-18. Buckling Mount Strap 2. Slide the wrist unit on your right or left arm as directed on page 5-7. 3. Insert your hand through the scanner mount. Inserting Mount: Left Arm Shown
Figure 5-19. Inserting Hand in Mount
5-10
Page 68
Operating the WSS 1000
4. Slide an appropriately sized o-ring onto your middle finger, or onto both your middle and ring fingers, and secure using the strap on the front of the mount.
Or
Figure 5-20. Attaching O-Ring 5. Pull the hand strap snug, then use the velcro to secure the strap. Place the lip on the front of the terminal mount over the velcro area on the scanner mount to secure the two units together.
Hand Mount Velcro Strap
Figure 5-21. Securing Strap 6. Wrap the trigger cable around the side of the scanner, next to your index finger, and secure using the velcro loop on the side of the mount. 7. Slide the trigger mount on your index finger, with the button positioned next to your thumb, and adjust the velcro strap.
Figure 5-22. Placing Trigger Mount on Finger
5-11
Page 69
WSS 1000 Product Reference Guide
5-12
Page 70
Chapter 6 Operating the WSS 1000 Power On and Off Because the WWC 1000 is battery powered, it is important to save power whenever possible. The period of time that the wrist computer can be used before recharging or replacing the battery can be increased by turning the wrist computer off when not entering data. When powered off, the WWC 1000 saves power by not performing process or display functions. Applications or data in memory are retained. Before the wrist computer powers up, it checks the battery for enough power to ensure reliable operation and data storage. When powered on, the display is restored and processing continues at the point where it was when the wrist computer was powered down. Powering the WWC 1000 on does not boot the system or initialize either the application or data. For more information regarding initialization, refer to Chapter 3, Batch and Spectrum One Initialization or Chapter 4, Spectrum24® RF Terminal Setup.
Normal Power To power the WWC 1000 on or off, press the Power button on top of the WWC 1000.
Power Button
Figure 6-1. Power Button 6-1