Page 74

Utilities and Diagnostic Tests

SUBNET MASK Enter SN Mask: 255.255.255.0

BkSp, CLR, Enter Figure A-15. Setting a Subnet Mask

Default Router The Default Router address is the node address that receives all packets destined for remote networks. To configure the Default Router: 1. Select Default Router to display the screen shown in Figure A-16. 2. Erase all or part of the entry. 3. Type an IP address in decimal using the ddd.ddd.ddd.ddd format. 4. Press CLEAR or ENTER to return to the main menu. DEFAULT ROUTER Enter D Router: 0.0.0.0

BkSp, CLR, Enter Figure A-16. Setting a Default Router

A-15

Page 75

VRC 6940 Product Reference Guide

Terminal IP Address If a boot server is not allocating IP addresses, you can set a Terminal IP Address: 1. Select MU IP Address to display the screen shown in Figure A-17. 2. Erase all or part of the entry. 3. Type an IP address in decimal using the ddd.ddd.ddd.ddd format. 4. Press CLEAR or ENTER to return to the main menu. MU IP ADDRESS Enter IP address: 0.0.0.0

BkSp, CLR, Enter Figure A-17. Setting aTerminal IP Address

Diversity To configure Diversity: 1. Select Diversity to display the screen shown in Figure A-18. 2. Use the UP or DOWN arrows to select an option. Always set Diversity set to No on VRC 6940 terminals with only one antenna. 3. Press CLEAR or ENTER to return to the main menu. DIVERSITY 2 antennas (Y/N) No

BkSp, CLR, Enter Figure A-18. Configuring Diversity

A-16

Page 76

Utilities and Diagnostic Tests

MU Sleep Mode If you set MU Sleep Mode On, the radio stays powered on when the rest of the terminal powers down because of inactivity. You can wake the terminal by sending a message directly to it, but broadcast messages will not wake it. If you set the switch Off, the radio powers off if the rest of the terminal powers down because of inactivity. The default setting is On. To configure MU Sleep Mode: 1. Select MU Sleep Mode to display the screen shown in Figure A-19. 2. Use the UP or DOWN arrow keys to select On or Off. 3. Press CLEAR or ENTER to return to the main menu. MU SLEEP MODE Radio State: On

BkSp, CLR, Enter Figure A-19. Setting Sleep Mode

Boot Mode This option determines what network communication parameters the terminal will use when it boots. To configure Boot Mode: 1. Select Boot Mode to display the screen shown in Figure A-20. 2. Use the UP or DOWN arrow keys to select Boot, DHCP, or Manual Entry options. 3. Press CLEAR or ENTER to return to the main menu. BOOT MODE Get IP from: Manual Entry

BkSp, CLR, Enter Figure A-20. Setting Boot Mode A-17

Page 77

VRC 6940 Product Reference Guide

Boot Mode Options: Boot

Broadcasts a TCP/IP BOOTP request to the network. If they have been configured to do so, boot servers on the network send a response. The terminal accepts the first valid response it receives, which contains a terminal IP address and other network parameters that override any parameters entered through CFG24.

DHCP

Uses the same process as the Boot option but uses the Dynamic Host Configuration Protocol.

Manual Entry

The terminal does not broadcast any configuration messages to the network. It uses the current network parameter values (saved in the radio flash) to connect to the network.

Power Management If power management is set to PSP (the default), the radio only powers up if there is traffic on the network. Because the radio is not always in a ready state when a message is sent to it, PSP mode slows response times. If power management is set to CAM, the radio is always ready to receive. To configure Power Management: 1. Select Pwr Management to display the screen shown in Figure A-21. 2. Use the UP or DOWN arrow keys to select PSP or CAM, then press ENTER. 3. Press CLEAR or ENTER to return to the main menu. PWER MANAGEMENT Radio Pwr Mode: PSP

BkSp, CLR, Enter Figure A-21. Configuring Power Management

A-18

Page 78

Utilities and Diagnostic Tests

Buffers To configure the terminal Buffers: 1. Select Buffers to display the screen shown in Figure A-22. 2. Use the UP or DOWN arrow keys to select 4, 8,or 12, then press ENTER. 3. Press CLEAR or ENTER to return to the main menu. BUFFERS Enter Buf Cnt: 8

BkSp, CLR, Enter Figure A-22. Configuring the Buffers

Re-Transmit Delay To configure the Re-Transmit Delay: 1. Select ReXmit Delay to display the screen shown in Figure A-23. 2. Use the UP or DOWN arrow keys to select short or long, then press ENTER. 3. Press CLEAR or ENTER to return to the main menu. REXMIT DELAY Enter Delay: short

BkSp, CLR, Enter Figure A-23. Setting the Re-Transmit Delay

A-19

Page 79

VRC 6940 Product Reference Guide

Rate Control To configure the Rate Control: 1. Select Rate Control to display the screen shown in Figure A-24. 2. Use the UP or DOWN arrow keys to select 1Mb only, 2Mb only, or 1Mb and 2 Mb options, then press ENTER. For Spring protocol, 1Mb is the only choice. RATE CONTROL TX Rate: 1 MB only

BkSp, CLR, Enter Figure A-24. Setting the Rate Control

Scanner/RF Operation To configure the Scanner/RF operation: 1. Select Scan/RF Op to display the screen shown in Figure A-24. 2. Use the UP or DOWN arrow keys to select Concurrent Op or Scan stops RF . Then press ENTER. If you want an attached scanner and the radio to both operate at the same time, select Concurrent Op. If you want radio operation to be suspended during a scan, select Scan stops RF. SCAN/RF OP Select Op Mode: Concurrent Op

BkSp, CLR, Enter Figure A-25. Setting Scanner/RF Operation

A-20

Page 80

Utilities and Diagnostic Tests

Flash Utility The flash.bat utility lets you copy, delete or rename files on the flash disk: it switches the flash disk to write mode, performs the operation, and then returns the flash disk to read-only mode. The LWP software copies flash.bat onto the E:\ drive the first time you start the terminal.

Deleting To delete a named file from the current directory of the flash disk: flash del filename.ext To delete all the files in the root directory of the flash disk: flash del \*.* Important! You don’t have to name the E: drive to erase all of the root directory files.

Copying To copy the protocol stack configuration file (net.cfg) from the current directory to the root directory on the flash disk: flash copy net.cfg \ To copy a file (filename.ext) from the SVTP directory on the flash disk to the STEP directory on the flash disk: flash copy e:\svtp\filename.ext \step Note: If you are copying from the E:\ drive, specify it on the first command parameter, but do NOT specify it on the second parameter, where it is assumed. You can only use this option to copy to the flash drive.

Renaming To rename netcfg.1 in the flash disk root directory to net.cfg: flash ren \netcfg.1 net.cfg Normal restrictions for a DOS file re-name apply, i.e., netcfg.1 must exist and net.cfg must not exist in the directory before the command is executed. A-21

Page 81