The text of a manual · part 10 of 15
VRC 6940 Product Reference Guide, pages 66 to 73
Pages 66 to 73 of 116
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol VRC-6940
Page 66
Utilities and Diagnostic Tests
6. Press 1, 2, 3 or 4 to select the number of pings you want to perform: <Test Mode> NUMBER OF PINGS 1. 100 pings 2. 500 pings 3. 1000 pings 4. Non-stop Select[1-4 or 'Q']:
Figure A-6. Selecting the Number of Pings 7. Press 1 or 2 to determine whether or not errors will cause the terminal to beep: <Test Mode> BEEP MODE 1. Beep on error 2. Silent Select[1-2 or 'Q']:
Figure A-7. Selecting the Number of Pings After you select the Beep Mode, the test starts (AP Ping Test or Field Diagnostics test).
A-7
Page 67
VRC 6940 Product Reference Guide
Ping Test During the AP Ping Test the terminal displays and updates this screen: Error Count
Association Indicator Ping Test Count
Access Point ID
AP PING TEST A Cnt Err AP RS 56 0 18 36 57 0 18 36 58 0 18 36 59 1 18 36 TMO 60 1 18 36 Press ‘Q’ to Quit
RSSI Indicator
Indicates an error
Figure A-8. The AP Ping Test Table A-4 describes the field contents. The reports wrap so that the last five message reports are visible. If you selected non-stop mode during setup, and the Ping Test or Error count fields overflow, then the first detail line shows the most significant digits of the count, prefixed with an asterisk. Table A-4. AP Ping Test Field Details Field
A-8
Description
Association Indicator
A, the radio is associating with an AP. U, the radio is not associating with an AP.
Ping Test Count
Displays the number of each test as it runs.
Error Count
Displays the cumulative number of errors that have occurred.
Access Point ID
The ID of the AP with which the terminal is associating.
RSSI Indicator
The Radio Signal Strength Indicator (RSSI) value. The RSSI range is 0 - 99. RSSI should be over 25 for a reliable connection.
Page 68
Utilities and Diagnostic Tests
When the test stops, the terminal displays a summary screen: AP PING TEST Total secs = 7.4 RF Secs = 6.7 Pings = 100 Packet size = 100 Timeouts = 4 [R]epeat or [Q]uit Figure A-9. Sample AP Ping Test Results Screen The summary shows: !
the elapsed time of the test
!
total pings transmitted
!
packet size used
!
retry count
!
number of timeouts
To repeat the test with the same parameters, press R. Press Q or CLEAR to end the test and return to the DIAG24 menu.
A-9
Page 69
VRC 6940 Product Reference Guide
Field Diagnostic Test During the Field Diagnostic Test the terminal displays and updates this screen: Error Count Retry Count
Association Indicator Ping Test Count
Timer AP PING TEST A Cnt Err Rty ms AP 56 0 0 165 18 57 0 0 55 18 58 1 1 TMO 18 59 1 0 220 18 60 1 0 58 18 Press ‘Q’ to Quit
Access Point ID
Figure A-10. The Field DiagnosticTest Table A-5 describes the field contents. The reports wrap so that the last five message reports are visible. If you selected non-stop mode during setup, and the Ping Test or Error count fields overflow, then the first detail line shows the most significant digits of the count, prefixed with an asterisk. Table A-5. Field Diagnostic Test Field Details Field
A-10
Description
Association Indicator
A, the radio is associating with an AP. U, the radio is not associating with an AP.
Ping Test Count
Displays the number of each test as it runs.
Error Count
Displays the cumulative number of errors that have occurred.
Retry Count
The retry count for this message.
Timer
The round-trip time in milliseconds, or an indication of error type, if there was an error.
Access Point ID
The ID of the AP with which the terminal is associating.
Page 70
Utilities and Diagnostic Tests
When the test stops, the terminal displays a summary screen: FIELD DIAGNOSTICS Total secs = 8.2 RF Secs = 4.9 Pings = 100 Packet size = 100 Timeouts = 4 [R]epeat or [Q]uit Figure A-11. The Field Diagnostic Test Results Screen The summary shows: !
the elapsed time of the test
!
total pings transmitted
!
packet size used
!
retry count
!
number of timeouts
To repeat the test with the same parameters, press R. Press Q or CLEAR to end the test and return to the DIAG24 menu.
A-11
Page 71
VRC 6940 Product Reference Guide
CFG24 Configurator Utility The CFG24 Spectrum24 Configurator utility lets you: !
configure radio communication parameters
!
initialize a configuration stored in the NET.CFG file in the terminal’s current directory
CFG24 updates NET.CFG settings every time it runs. It saves parameter settings to the radio flash storage initialization area, and then checks for an association between the terminal and an Access Point (AP). Note: The Spectrum24 DOS ODI driver must be installed before you use CFG24.
Starting the Utility There are two ways to start the utility: 1. The first time you power up a VRC 6940 terminal the terminal loads essential utilities and system drivers and displays the CFG24 Configurator utility as shown in Figure A-12. 2. Alternate method: go to a DOS prompt and type: CFG24 [-I]. How you get to a DOS prompt depends on what applications have been loaded onto the terminal, and how they have been programmed. The DOS prompt may also appear if you boot the terminal and it cannot connect to the network. The optional parameter [-I] initializes the current configuration. If you are configuring the terminal for the first time, this option starts the utility and displays the Configurator menu.
Initializing the Radio When you use the [-I] parameter, the utility initializes the radio using the settings currently stored in NET.CFG. Default settings: NET_ID: Terminal IP address:
A-12
101 10.x.y.z (x, y, and z are the last 3 bytes of the IEEE address)
Subnet mask:
255.0.0.0
Default router:
0.0.0.0
Page 72
Utilities and Diagnostic Tests
The Configurator Menu The Configurator menu appears the first time you start the terminal, or if you launch the CFG24 program without parameters. Figure A-12 shows Configurator menu options. Note that some terminals do not allow you to change the Subnet Mask, Default Router, and Terminal IP addresses. If you are using Spectrum24 802.11 protocolbased software, the menu shows the ESS ID option. For Spectrum24 Spring protocolbased software, the menu shows Net ID.
Configuration Note: Navigating the Menus To navigate through the menus: • Press UP or DOWN arrow keys to scroll through menu options. • To select, highlight the menu option you reverse want, thenvideo press ENTER. A highlighted option shows up in reverse video . • To erase part of an entry,video press BACK. reverse • To return to a previous menu press CLEAR. • To exit to a DOS prompt, return to the Configurator menu and press CLEAR.
CONFIGURATOR X.XX View config ESS Id Subnet Mask Default Router MU IP Address Diversity ^ CLR, Enter
^
Figure A-12. The CFG24 Configurator Menu
View Config Parameters The View config option shows the terminal’s IEEE address, IP address, firmware version number, and ESS ID or Net ID. To display the existing configuration parameters: 1. Select View config. Figure A-13 shows an example of the screen that appears. 2. Press CLEAR or ENTER to return to the Configurator menu. VIEW CONFIG Terminal IEEE addr 00:A0:F8:28:78:EF MU IP Address 0.0.0.0 FW: V3.29 981116 Net ID=101 CLR, Enter
Figure A-13. Viewing Configuration Parameters A-13
Page 73
VRC 6940 Product Reference Guide
ESS ID or Net ID An ESS or Net ID identifies a radio network and differentiates between radio networks. All equipment on one network must use the same ESS or Net ID. Spectrum24 terminals can support the Spectrum24 802.11 or Spectrum24 Spring protocols. The menu displays the ESS ID or Net ID, depending on which protocol you are using. Terminals using Spectrum24 with the 802.11 protocol require an ES SID. The ES SID is a a 32-character alphanumeric value. Terminals using Spectrum24 with the Spring proprietary network protocol require a Ne tID. The Ne tID is a three-character hexadecimal value. To configure a terminal’s ESS ID or NET ID: 1. Select ESS ID or Net ID. Figure A-14 shows the entry for a Spring-based terminal. 2. Erase all or part of the entry, and type a new value from 100 to 1FE. 3. Press CLEAR or ENTER to return to the Configurator menu. NET ID Enter Net Id: 150
BkSp, CLR, Enter Figure A-14. Setting a NET ID
Subnet Mask To configure the Subnet Mask: 1. Select Subnet Mask to display the screen shown in Figure A-15. 2. Erase all or part of the entry. 3. Type an IP address in decimal using the ddd.ddd.ddd.ddd format. 4. Press CLEAR or ENTER to return to the main menu.
A-14