Page 189

Applications: HotSync®

4. Tap the check boxes to de-select the files and/or applications that you do not want to synchronize during a modem HotSync operation. The default setting is to synchronize all files. Note: Applications that do not have a database (such as games) do not synchronize, even if the item is selected in the Conduit Setup screen. 5. Tap the OK button to close the Conduit Setup screen and activate your settings for the next modem HotSync operation.

Performing a HotSync Operation via Modem To perform a Modem HotSync operation: Note: If you are not using a PalmPilot modem, you need a special modem cable and an external modem. Connect one end of the special modem cable to the serial connector on the SPT 1700 terminal and the other end to the external modem. Do not attempt to use other kinds of cables, even if they appear to be similar. 1. Tap the icon to open the HotSync application.

2. Tap the large icon to dial the Symbol Palm Terminal Desktop modem and synchronize the applications selected under Conduit Setup. 3. Wait for the HotSync operation to complete. If you have any problems conducting a HotSync operation, refer to Troubleshooting on page 20-9.

9-17

Page 190

SPT 1700 Series Product Reference Guide

Conducting Wireless HotSync Operations Using HotSync you can take advantage of the LAN and WAN connectivity available in business environments. You can dial in to a network or use a cradle that is connected to any computer on your LAN or WAN (provided that the computer connected to the cradle also has HotSync installed, your computer is on, and the HotSync Manager is running).

Setting Up for a Wireless HotSync The SPT 1733, 1734, and 174x terminals allow you to perform a HotSync without using a cradle over a terminal specific wireless LAN (174x) or WAN (173x). This section describes the setup necessary for a wireless HotSync to occur. Before a wireless HotSync can be performed, each terminal must be properly configured for use. Refer to Chapter 2, Network Setup for specific instructions for each terminal. Once the terminal is properly configured for use, it must be set up to perform a wireless HotSync over the LAN or WAN. To properly configure your terminal: 1. Tap the icon to open the Applications Launcher.

2. Tap the icon to open the HotSync application.

3. Tap the Prefs.

icon to display the HotSync Options menu and select Modem Sync

Select Network and tap OK. 4. Tap LANSync Prefs from the Options menu and select Local HotSync. 5. Tap Primary PC Setup on the Options menu. Note: The Primary PC Setup is extremely important! It tells the terminal how to locate the machine which it will synchronize with on the network.

9-18

Page 191

Applications: HotSync®

The Primary PC Setup screen displays:

The information required for this screen is located by selecting the TCP/IP button on the Network tab of the HotSync Manager on the machine you are hotsyncing to. Copy down the Primary PC Name, Primary PC address, and the Subnet mask, and enter that information manually on the above screen. Refer to Selecting HotSync Setup Options on page 9-9 for details on how to access the Network tab. Note: If the Subnet Mask box on your PC is empty, you do not need to enter anything in that section on your terminal. 6. Tap OK. 7. Tap Connection Setup on the Option menu and select: a. Spectrum24 for a SPT 174x terminal b. Merlin for a SPT 1733 (CDPD) terminal, or, c. GSM Modem for a SPT 1734 terminal

Performing a Spectrum24 HotSync Note: This function is available on SPT 174x terminals only. To perform a HotSync via the Spectrum24 wireless LAN: 1. Ensure the terminal has been properly configured for use. Refer to Setting Up for a Wireless HotSync on page 9-18 for details. 2. Select the HotSync application from the main application screen. 3. Tap Modem, and tap Select Service to display the Network Preference Screen.

9-19

Page 192

SPT 1700 Series Product Reference Guide

Verify that Spectrum24 displays in the Service pick list and that phone setup information is accurate and tap Done. 4. Tap the HotSync button to initiate the HotSync.

Performing a CDPD HotSync Note: This function is available on SPT 1733 terminals only. To perform a HotSync via the CDPD wireless WAN: 1. Ensure the terminal has been properly configured for use. Refer to Setting Up for a Wireless HotSync on page 9-18 for details. 2. Tap the icon to open the HotSync application.

3. Tap Modem, and tap Select Service to display the Network Preference screen. 4. Verify that Merlin displays in the Service pick list and that phone setup information is accurate and tap Done. 5. Tap the HotSync button to initiate the HotSync.

9-20

Page 193

Applications: HotSync®

Performing a GSM HotSync Note: This function is available on SPT 1734 terminals only. Before performing a GSM HotSync, you must first set up the modem registration information. To do so: 1. Tap the icon to open the Applications Launcher.

2. Tap the icon to open the GSM Demo application. The main screen displays:

3. Select the Leave modem registered checkbox. Note: This option can only be set if the modem has been registered. 4. Exit GSM Demo. Ensure the terminal has been properly configured for use. Refer to Setting Up for a Wireless HotSync on page 9-18 for details. 5. Tap the icon to open the Applications Launcher.

6. Tap the icon to open the HotSync application.

7. Tap Modem, and tap Select Service to display the Network Preference Screen. 8. Verify that the GSM modem displays in the Service pick list and that phone setup information is accurate and tap Done. 9. Tap the HotSync button to initiate the HotSync. When the HotSync is complete and if a registered modem is no longer needed, open GsmDemo and de-register the modem (Refer to Using GsmDemo on page 18-3 for details). This action will save battery life.

9-21

Page 194

SPT 1700 Series Product Reference Guide

Setting Up the Ethernet Cradle for HotSync The CRD1700-4000E appears to SPT 1700 terminals inserted into the cradle as a dial-up PPP service. Therefore, just as you would set up a Palm III terminal to connect to an Internet Service Provider (ISP) like Compuserve or Earthlink, the SPT 1700 terminals must be configured for use with the cradle. This section describes the steps necessary to configure both the SPT 1700 terminal and the CRD1700-4000E.

Installing NetSync An SPT 1700 terminal must have NetSync installed and configured for it to communicate with the CRD1700-4000E. Additionally, NetSync extensions to the HotSync Manager must be installed on the host system which the SPT 1700 terminal is to synchronize with. The Network HotSync software is a free add-on for SPT 1700 terminals and is available at http:/ /www.palm.com/custsupp/downloads/netsync.html. Follow the instructions to install the network HotSync software on your host PC, then perform a HotSync to install the program on your SPT 1700 terminal.

Configuring NetSync Options Once NetSync is installed on your SPT 1700 terminal, it must be configured for use with the CRD1700-4000E. From the HotSync panel on your SPT 1700, select each of the option panels available from the “Options” menu (accessed by tapping the Menu icon) and configure them as follows: 1. To configure Modem Sync Preferences: 2. Tap the icon to open the HotSync menus.

3. Tap Modem Sync Preferences from the Options menu to display the Modem Sync Preferences screen. 4. Select Network. 5. Tap OK. 6. To configure the Local Sync Preferences: a. Tap the icon to open the HotSync menus.

b. Tap LANSync Preferences from the Options menu to display the LANSync Preferences screen. c. Select Local HotSync (the CRD1700-4000E doesn’t use LANSync functionality). d. Tap OK.

9-22

Page 195

Applications: HotSync®

7. To configure the Primary PC Setup, refer to the Setting Up for a Wireless HotSync on page 9-18 for details: Note: Primary PC Setup is extremely important! It tells the terminal how to locate the machine which it will synchronize with on the network. 8. Tap the icon to open the HotSync menus and select Conduit Setup.

a. Check any items that you want synchronized and uncheck any items that you don’t want synchronized. b. Tap OK. 9. Tap the icon to open the HotSync menus and select Connection Setup.

a. For optimal performance, choose a communication rate of 57600 bps and a Standard modem. b. Tap Done.

Creating a CRD1700-4000E Modem Sync Service The SPT 1700 terminal communicates with the CRD1700-4000E via a Modem Sync. The Modem Sync offers many options which must be configured for use with the CRD17004000E. Create a separate CRD1700-4000E network configuration and select it as your default Modem Sync service. Use either Graffiti or the keyboard feature (click in the lower left-hand corner of the scratch pad on the abc to access the keyboard) to enter the following information: 1. Tap the icon to open the HotSync application.

2. Choose the Select Service box under the Modem Sync icon to create a new CRD1700-4000E service. 3. To select the Earthlink service, Click Menu, Duplicate. 4. Change the service name to CRD1700-4000E. Leave the user name and password blank. You may enter any phone number you want, except ‘00’, or you may leave it blank. The SPT 1700 terminal will not be able to HotSync if you use ‘00’ as a phone number.

9-23

Page 196

SPT 1700 Series Product Reference Guide

Configuring the Remote Host PC for Use with the Ethernet Cradle The remote PC you wish to HotSync the SPT 1700 to must be set up for Network HotSync and configured to run from the network. 1. Make sure HotSync Manager is installed and running. 2. From the HotSync Manager, make sure Network is checked. If you don’t want HotSync Manager to use a serial port, make sure Local is unchecked. Note: The PC must be configured for proper TCP/IP network operation.

The Ethernet HotSync Process Once the CRD1700-4000E is properly connected, data communication between an SPT 1700 terminal and the host computer can take place. When a terminal is inserted in the cradle, the cradle detects its presence and attempts to initiate the HotSync process on the terminal. All local slots in the cradle operate simultaneously; the HotSync procedure starts immediately when any terminal is inserted into a local slot. As stated earlier, if multiple slots are to be HotSync’d simultaneously, each must communicate with a different host PC. If the application requires simultaneous connection to a single host database, additional software, available from Symbol, is required. Terminals inserted into daisy-chained cradles are HotSync’d in a round-robin fashion simultaneously with any HotSyncs from local slots. Daisy-chained cradles share a logical “fifth slot” on the CRD1700-4000E, which, while it shares equal priority with the local slots, allows only one HotSync at a time.

Performing HotSync with the Ethernet Cradle To initiate communication between the terminal and the host, gently insert the SPT 1700 terminal into a local cradle slot, or a slot on an inter-connected serial cradle. Do not force. When properly inserted, the slot’s LED turns red, then changes to flashing green, indicating that the host and the terminal are communicating. Removing the terminal from the cradle while the LED is flashing green will result in a disruption of communication data may be lost. If the terminal is inserted into an inter-connected serial cradle slot while another terminal on the serial cradle chain is communicating with a host, the terminal waits (its LED remains red) until the first terminal finishes communicating. After the communication session completes, the slot’s LED turns solid green and remains green until the terminal is removed from the slot. To remove the terminal, pull it straight up from the slot. 9-24