Page 181
Applications: HotSync®
Conducting a Local HotSync Operation After you complete the first HotSync operation, the HotSync process is even faster and easier! To conduct a local HotSync operation: 1. Insert the SPT 1700 terminal in the cradle, or connect the synchronization/charging cable. 2. Start the HotSync Manager. 3. Press the button on the front of the CRD1700-1000S cradle to start the HotSync process. If you are using the synchronization/charging cable or the CRD 1700-4000S cradle, tap the icon on the terminal’s application screen. Synchronization begins immediately. 4. Wait for the Symbol Palm Terminal Desktop to display a message indicating that the process is complete.
Selecting HotSync Setup Options You can choose when you want HotSync Manager to run, and adjust the local, modem, and network HotSync settings. To set the HotSync Options: 1. Click the icon in the Windows System Tray to open the HotSync Manager menu and click Setup. The Setup dialog displays with the General tab open: .
9-9
Page 182
SPT 1700 Series Product Reference Guide
2. Select one of the following options: Always available
Adds HotSync Manager to the Startup folder and constantly monitors the communication port for SPT 1700 terminal synchronization requests. With this option, the HotSync Manager conducts synchronizations even when the Symbol Palm Terminal Desktop is not running.
Available only Starts HotSync Manager and monitors requests automatically when the Symbol when you open the Symbol Palm Terminal Desktop software. Palm Terminal Desktop is running Manual
Starts the HotSync Manager and monitors requests only when you select HotSync Manager from the Start menu.
Tip: If you’re not sure which option to use, use the Always available default setting. 3. Click the Local tab to display the settings for the connection between your computer and the SPT 1700 cradle or synchronization cable, and adjust the options as needed.
Serial Port
9-10
Identifies the port Symbol Palm Terminal Desktop will use to communicate with the cradle or the synchronization/charging cable. This selection should match the port number where you connected the cradle or synchronization/charging cable. Note: Your SPT 1700 terminal cannot share this port with an internal modem or other device. If you have trouble determining the correct serial port, refer to Troubleshooting on page 20-9.
Page 183
Applications: HotSync®
Speed
Determines the speed at which data is transferred between your SPT 1700 terminal and Symbol Palm Terminal Desktop. We suggest you try the As Fast As Possible rate first, and adjust downward if you experience problems. This setting allows the Symbol Palm Terminal Desktop and SPT 1700 terminal to find and use the fastest speed.
4. Click the Modem tab to display the Modem settings and adjust the options as needed.
Serial Port
Identifies the port where the modem is located. If you are unsure of the port assignment, review the Modem Properties in the Windows Control Panel.
Speed
Determines the speed at which data is transferred. We suggest you try the As Fast As Possible rate first, and adjust downward if you experience problems. This setting allows the Symbol Palm Terminal Desktop and SPT 1700 terminal to find and use the fastest speed.
Modem
Identifies the modem type or manufacturer. Refer to your modem manual or face plate for its type or settings. If you’re not sure of your modem type or your modem doesn’t match any that appear in the list, choose Hayes Basic.
Setup String
Identifies the setup string for your particular modem. Not all modems require a setup string. Refer to your modem manual and enter the setup string if recommended by the manufacturer.
5. Click the Network tab to display Network settings and adjust the options as needed.
9-11
Page 184
SPT 1700 Series Product Reference Guide
Note: You must have Network HotSync software installed to use this feature. Refer to Configuring NetSync Options on page 9-22.
6. Click TCP/IP Settings to obtain the Primary PC Name, Address, and Subnet Mask (optional) for the selected user. 7. Click OK to close the Setup dialog.
Customizing HotSync Application Settings For each application you can define a set of options that determines how records are handled during synchronization. These options are called a “conduit.” By default, the Symbol Palm Terminal Desktop synchronizes all files between the SPT 1700 terminal and the Symbol Palm Terminal Desktop. In general, you should leave the settings to synchronize all files. The only reason you might want to change these settings is to overwrite data on either your SPT 1700 terminal or Symbol Palm Terminal Desktop, or to avoid synchronizing a particular type of file because you don’t use it. In addition to the standard application conduits, the Symbol Palm Terminal Desktop includes System and Install conduits. The System conduit backs up the system information stored in your SPT 1700 terminal, including Graffiti software ShortCuts. The Install conduit is used to install Palm-compatible applications. To customize HotSync application settings: 1. Click the menu.
9-12 icon in the Windows System Tray to open the HotSync Manager
Page 185
Applications: HotSync®
Tip: You can also click the HotSync command on the Symbol Palm Terminal Desktop menu bar to open the HotSync Manager menu. 2. Click Custom from the HotSync menu to open the Custom dialog.
3. Select the appropriate user name from the drop-down list. 4. Select an application in the Conduit list to choose the conduit you want to change. 5. Click the Change button to open the Change HotSync Action dialog.
Check here to make new settings the default Click to skip data transfer for an application
6. Determine the action you want to take. Note: Changing the HotSync setting from the default affects only the next HotSync operation. Thereafter, the HotSync Actions revert to their default settings. To use a new setting on an ongoing basis, check the Set As Default box. Clicking the Default button in the Custom dialog will revert to the new default settings.
9-13
Page 186
SPT 1700 Series Product Reference Guide
7. Repeat steps 2 through 6 to change conduit settings for other applications or for a different user name. 8. Click the OK button to close the Change HotSync Action dialog and activate your settings.
Conducting a HotSync Operation via Modem You can use a modem to synchronize your SPT 1700 terminal when you are away from your computer. Note: You must first conduct an initial local HotSync operation using any of the SPT 1700 cradles before you perform a modem HotSync operation. Refer to Conducting a Local HotSync Operation on page 9-9 for details. To perform a HotSync operation via modem you need: •
A modem connected to your computer.
•
A modem connected to your SPT 1700 terminal with a special modem cable. (The cradle is not used for a modem HotSync operation.)
•
The Symbol Palm Terminal Desktop software configured for use with a modem as described in Selecting HotSync Setup Options on page 9-9.
Preparing Your Computer for a Modem HotSync Operation There are several steps you must perform to prepare your computer for a modem HotSync operation. Be sure to perform these steps before you leave your office so that your computer is ready to receive a call from your SPT 1700 terminal.
9-14
Page 187
Applications: HotSync®
To prepare your computer for a modem HotSync operation: 1. Confirm that the computer modem is connected and turned on, and that no communications applications, such as fax or telephony software, are running on a COM port. Note: Make sure the computer is disconnected from all online services, such as America Online (AOL) and CompuServe. This helps to avoid conflicts with the COM port. 2. Start HotSync Manager and select Modem from the HotSync Manager menu. Refer to Selecting HotSync Setup Options on page 9-9 for details about this screen.
Preparing Your SPT 1700 Terminal for a Modem HotSync Operation To prepare your SPT 1700 terminal for a modem HotSync operation: 1. Tap the icon to open the Applications Launcher.
2. Tap the icon to open the HotSync screen.
3. Tap Modem and select your modem from the pick list. Note: This will vary, dependent upon the SPT terminal you are using: SPT 1733 terminals use Merlin, SPT 1734 terminals use GSM modem, and SPT 174x terminals use Spectrum24. 4. Tap Enter Phone # to open the Phone Setup screen.
9-15
Page 188
SPT 1700 Series Product Reference Guide
Note: If you have Network HotSync software installed on your SPT 1700 terminal, the Remote Setup screen displays instead. Refer to Network Preferences and Symbol Palm Terminal Desktop TCP/IP Software on page 14-13 for more information. 5. Enter the telephone number to access the modem connected to your computer. 6. If needed, enter a dial prefix (such as “9”) to access an outside line, and then tap the Dial Prefix check box. Tip: You can enter a comma in the field to introduce a “pause” in the dialing sequence. 7. If the phone line you’re using for the SPT 1700 terminal has “Call Waiting,” select the Disable call waiting check box to avoid an interruption during the modem HotSync operation. 8. If you want to use a calling card to place the call, select the check box and enter the calling card number. 9. Tap OK to return to the HotSync screen. 10. Tap the icon to open the HotSync menus.
11. Tap Modem Sync Preferences from the Options menu to display the Modem Sync Preferences screen. 12. Select Direct to Modem. 13. Click OK.
Selecting the Conduits for a Modem HotSync Operation The Conduit Setup screen on your SPT 1700 terminal enables you to define which files and/or applications synchronize during a modem HotSync operation. Use these settings to minimize the time required to synchronize data with a modem. To change the Conduit Setup for a modem HotSync operation: 1. Tap the icon to display the HotSync screen.
2. Tap the icon to open the HotSync menus.
3. Tap Conduit Setup from the Options menu to open the Conduit Setup screen.
9-16