The text of a manual · part 25 of 46
SPT 1700 Series Product Reference Guide: Chapter 10 Applications: ScoutSync Client
Pages 197 to 204 of 394, from SPT 1700 Series Product Reference Guide
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SPT-1700, Symbol SPT-1733 1734, Symbol SPT-1740 and Symbol SPT-1746
Page 197
Chapter 10 Applications: ScoutSync Client Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Overview of the ScoutSync Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Configuring the ScoutSync Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Selecting Conduits for Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5 Performing a Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Automatically Synchronizing Using a Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Viewing the Synchronization Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7 ScoutSync Client Menu Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-8 Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-8
10-1
Page 198
SPT 1700 Series Product Reference Guide
10-2
Page 199
Applications: ScoutSync Client
Introduction This chapter explains how to configure and use the ScoutSync Client on an SPT 1700 terminal. By reading this chapter, you will learn how to perform a synchronization and view your ScoutSync Client synchronization log. Note: Before performing the procedures found in this chapter, your system administrator should install, set up, and run ScoutSync on a computer. Your system administrator must also grant you access to a Scout Server.
Overview of the ScoutSync Client The ScoutSync Client is an application that enables you to connect your SPT 1700 terminal to a Scout Server. A Scout Server resides on a Windows NT server or workstation that your system administrator manages and is responsible for transferring data between the ScoutSync Client and your company’s back-end applications and databases. Using Scout’s powerful technology, you can seamlessly transfer data using an SPT 1700 terminal from virtually anywhere to your company’s data stores. Using the ScoutSync Client on your SPT 1700 terminal, you can: •
Run ScoutSync Conduits A ScoutSync Conduit is the central processing component that implements the synchronization logic during a synchronization session. Your system administrator installs conduits on your device.
•
Initiate a synchronization session
•
View your SPT 1700 terminal’s synchronization log.
10-3
Page 200
SPT 1700 Series Product Reference Guide
Configuring the ScoutSync Client The Scout Preferences settings enable you to connect a mobile device to a ScoutSync Server. When configuring the preferences, you must specify the Scout host/server name, the command port used for ScoutSync Client/Server communications, and the user's profile/ID. Note: You must configure the settings before performing a synchronization. To configure the ScoutSync Client preferences of an SPT 1700 terminal: 1. Tap the icon to open the Applications Launcher.
2. Tap the icon to open ScoutSync. The main ScoutSync screen displays:
3. Tap the Preferences button. The following screen displays:
4. Enter the Scout Server Name and the Port Number. The default connection port is 8025 and should not be changed unless instructed by your system administrator. 5. Enter the Profile.
10-4
Page 201
Applications: ScoutSync Client
6. Tap the word “Unassigned” in the Password field to display the Password box. If applicable, enter a password and tap the OK button. If not, tap Cancel. Note: “Assigned” replaces “Unassigned” after you enter a password. 7. Tap the More button. The Advanced Preferences screen displays:
•
To synchronize on application launch, tap the Start sync on app launch check box.
•
To close the network connection after a synchronization, tap the Close connection after sync check box.
•
To be notified about errors, tap the Notify about errors during sync check box.
•
To indicate that you are using a Novatel Minstrel modem, tap the Check modem status before sync check box.
8. Tap OK twice to close the Scout Preferences screen.
Selecting Conduits for Synchronization Developers have the ability can create custom conduits for synchronizing data. Before performing a synchronization, you can specify the conduits you want activated. Each conduit is associated with an application and determines how data is handled during a synchronization session. When a conduit is selected for synchronization, it knows what actions to perform and how to process the files and databases. To select conduits for synchronizing an SPT 1700 terminal: 1. Tap the icon to open ScoutSync. The main ScoutSync screen displays.
2. Tap the icon to open the Conduit List.
3. Tap the checkboxes of the conduits that you want to synchronize. 4. Tap Done.
10-5
Page 202
SPT 1700 Series Product Reference Guide
Performing a Synchronization To perform a synchronization: 1. Tap the icon from the Applications Launcher. The following screen displays:
2. Tap the icon.
The synchronization process begins.
Automatically Synchronizing Using a Cradle You can configure a mobile device to automatically start and connect to a server when placed in the cradle. Once the device is configured, when placed in a cradle it will automatically perform a synchronization until you disable the feature. To automatically synchronize using a cradle with an SPT 1700 terminal: 1. Open the Applications Launcher. 2. Tap the icon.
3. Tap the pick list in the upper-right corner and select Buttons. The following screen displays:
10-6
Page 203
Applications: ScoutSync Client
4. Tap the HotSync button to open HotSync. The following screen displays:
5. Select ScoutSync from the Cradle pick list. 6. Return to the Applications Launcher and tap the screen is displayed.
icon. The main ScoutSync
7. Tap Preferences, then More. The Advanced Preferences screen displays:
8. Select the Start sync on app launch check box and tap OK. 9. Place the SPT 1700 terminal in the cradle.
Viewing the Synchronization Log The synchronization log of a mobile device displays a record of the date and time a user logged on and off a server. It also displays the list of files and databases installed on the mobile device and other informational messages. To view the Synchronization Log: 1. Tap the icon. The main ScoutSync screen is displayed.
2. Tap the View Log button. The ScoutSync Log is displayed. Note: Only the most recent synchronization session log displays.
10-7
Page 204
SPT 1700 Series Product Reference Guide
ScoutSync Client Menu Commands ScoutSync Client includes menu commands to make it fast and easy to perform common tasks. This section explains the menu commands specific to ScoutSync. Refer to Using Menus on page 3-20 for information about menu commands common to most of your SPT 1700 terminal applications.
Options Menu When you select the Options menu, its commands display on the screen.
Conduit List
Allows you to choose which conduits run during ScoutSync.
ScoutSync
Automatically attempt a ScoutSync connection.
Preferences
Opens the Scout Preferences screen, where you can enter the Scout Server name, port number, profile, and password.
Network Settings
Opens the Preferences screen, where you set up your service and connection preferences.
About
Provides version information.
10-8