Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 37

PPT 4300 Series Product Reference Guide: Chapter 6 The Control Panel, pages 135 to 142

Pages 135 to 142 of 326, from PPT 4300 Series Product Reference Guide

The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PPT-4340

Page 135

The Control Panel

System Options The System tab displays system information for the terminal. To make changes, follow the instructions in Navigating the Control Panel on page 6-4. The options on this page require a password, if one exists. This tab also allows you to: !

select a start-up application

!

view software versions

!

set or change the Control Panel password

!

enable or disable booting from the PC Expansion Slot

!

set Quiet Mode on or off

Figure 6-7. Control Panel System Tab Note: If you change the Current Time, immediately select that the time is saved promptly.

so

6-17

Page 136

PPT 4300 Series Product Reference Guide

Settings and Information Current Date: Shows the current date. You can edit this field. Current Time: Shows the current time. You can edit this field. Flash Size: The default setting for this field is 2MB. Do not change this setting unless you are adding or partitioning an internal flash expansion module. To change the setting, click the arrows at the end of the field. On standard terminals, the options are 0 and 2, but setting this field to 0 disables the on-board Flash memory. On terminals with Flash Expansion modules, you can set a higher flash size, available options depend on the size of the Flash Expansion module. For more information, see Partitioning a Flash Expansion Module on page 3-26. RAM Size: Shows the size of the on-board RAM. This field is for display only. Display Type: Shows the screen display type and resolution. This field is for display only. Enable PC-Card Boot: If this option is selected, when the PPT 4300 powers on, it -will attempt to boot first from a PC card in the Expansion Slot. If there is no card in the Expansion Slot, it attempts to boot from the internal flash. To prevent the terminal from booting from a PC card, make sure this option is not selected. Quiet Mode: Some host applications may cause the terminal to beep when some actions occur (Note: this is different from the Key Click option described on page 6-11). To prevent this, select Quiet Mode. To enable the beeps from the host, make sure Quiet Mode is not selected.

DOS Start-up Menu Configuration This box allows you to select which application will run once a terminal powers up and finishes booting. Select the radio button for the application that you wish to start. See ROMDOS Start-up Menu on page 4-6 for more information.

Software Versions Press to see a list of the software currently loaded and running on the terminal’s flash file system. If you have booted from the PPT 4300 Utilities PC card and the loaded software comes from the PC Card, then you will get the versions of the software on the PC Card. If you boot from the internal flash and the loaded software comes from the internal flash, you will see the versions of the software on the internal flash. To dismiss this list, select the Close button.

6-18

Page 137

The Control Panel

Figure 6-8. Software Versions Pop-up Window

Setting a Password Press the button to add or change a password for the Control Panel. See Setting or Changing the Control Panel Password on page 6-5 for more information.

6-19

Page 138

PPT 4300 Series Product Reference Guide

Network Options For terminals that communicate with a network, the Network tab displays information about the terminal’s current communications configuration. If you change the settings on this page, you change the terminal’s ability to communicate with the network. Also, if you make changes that directly affect communications, the terminal will reboot when you exit the Control Panel, to activate the changes. To make changes, follow the instructions in Navigating the Control Panel on page 6-4. The options on this page require a password, if one exists.

Figure 6-9. Control Panel Network Page

6-20

Page 139

The Control Panel

TCP/IP Configuration This section of the screen allows you to set information in the fields listed below:

Terminal Name This field holds the Citrix ICA Client name for the terminal (up to 15 alphanumeric characters). This name appears on Citrix server administration screens. We recommend naming the terminal according to serial number or a unique terminal ID.

Terminal IP Address This field holds the terminal’s network address. Networks use IP addresses to determine where to send data that is being transmitted over a network. An IP address is a 32-bit number commonly specified as a series of 8-bit numbers in decimal dot notation (e.g., 199.99.99.5). The highest 8-bit number you can use is 254. This field is required.

Gateway Address This field holds the IP address for a network gateway or router. A terminal is part of a subnet as specified by its IP Address and Netmask. It can send packets directly to any node that is on the same subnet. If the destination node is on a different subnet, then the terminal sends the packet to the gateway first. The gateway then determines how to route the packet to the destination subnet. This field is only required if a gateway is needed to reach the host.

Subnet Mask This is a number that the network uses to determine whether or not one device can communicate directly with another (e.g., a terminal attempting to communicate with a host computer). In some cases, devices must communicate indirectly through a gateway. The network system uses the subnet mask to compare the IP addresses of the two devices involved and determine whether they will communicate directly or indirectly. The subnet mask depends on your facility’s IP address allocations. If the special subnet mask of “255.255.255.255” is specified, then the TCP driver (tn_tcpip.exe) used by the Terminal Emulators will calculate a subnet mask derived from the first 2 bits of the Terminal IP Address. However if your facility uses site-specific subnets, you may need to set a different subnet mask.

DNS Server If you are using the Microsoft TCP stack, use this field to specify the IP address for a Domain Name Server (DNS). It allows users to use server names, rather than IP addresses. To use this feature with the Microsoft TCP stack, you must load DNS software (dnr.exe). If you are using a Novell TCP stack, you must specify a DNS by editing the c:\net\resolv.cfg file. Contact Symbol Technical Support for more information.

6-21

Page 140

PPT 4300 Series Product Reference Guide

Domain Name If you are using the Microsoft TCP stack, use this field to specify the Domain Name for a DNS server (e.g., symbol.com). To use this feature with the Microsoft TCP stack, you must load DNS software. If you are using a Novell TCP stack, you must specify a Domain Name by editing the c:\net\resolv.cfg file. Contact Symbol Technical Support for more information.

RF Configuration This box allows you to set the RF Domain (NetID), ESS ID (802.11 radio) and the Wireless Signal Strength Threshold (RSSI).

RF Domain (NetID) Use this option for terminals with Spectrum24 cards using the Spring communications protocol (and for cards using the 802.11 protocol, if no ESS ID has been defined). A NetID allows facilities to restrict which Access Points a PPT 4340 terminal can communicate with. This field is required. Use a hexadecimal number, e.g., ‘0x101’ or its decimal equivalent, e.g., ‘255’. A terminal can only communicate with Access Points that have matching NetIDs. See the Spectrum24 documentation for more information. This parameter is saved in \lanman.dos\protocol.ini and \net\net.cfg, if they exist.

ESS ID (802.11 radio) This field only appears in Control Panel versions 1.87 and later. Use this option for terminals with Spectrum24 cards using the 802.11 communications protocol. An ESS ID allows facilities to restrict which Access Points a PPT 4340 terminal can communicate with. A terminal can only communicate with Access Points that have matching ESS IDs. The ESS ID is an alphanumeric, case-sensitive network identifier. It is 1 to 32 (ASCII) bytes in length. If the ESS ID contains spaces, enclose it within single quotation marks. If the ESS ID contains numbers, enclose it within double quotation marks. See the Spectrum24 documentation for more information. This parameter is saved in \lanman.dos\protocol.ini and \net\net.cfg, if they exist. If the ESS ID is not present, the terminal uses the NetID.

Tx Rate Use this option for terminals with Spectrum24 cards using the 802.11 communications protocol. This field controls the rate at which a terminal communicates with a Spectrum24 Access Point. If the terminal has a 2 Mbps radio, you can set this field to 1 or 2. When the field is set to 1, the terminal communicates at the rate of 1 Mbps and can only communicate with 1 Mbps Access Points. When set to 2, it communicates at 2 Mbps and can only communicate with 2 Mbps Access Points. On terminals with 2 Mbps radios, 2 is the default value for this field. If the terminal has a 1 Mbps radio, then the only option available is 1.

6-22

Page 141

The Control Panel

Wireless Signal Strength Warning Threshold This field lets you set the Received Signal Strength Indicator (RSSI) value that will cause a pop-up warning message to appear. The message immediately alerts users that they have entered an area of poor radio coverage, so they can get back in range. The RSSI has a range of 0 to 99. Normal operating range is 25 to 65. Below 25, the terminal is likely to roam for a better connection. Below 20, you may lose your connection with the host computer. To disable the message, set this field to 0. The pop-up message appears when the signal drops below the level set in this field, or when the terminal is roaming. This message can also be set or disabled in ppt4300.ini (see Settings in ppt4300.ini on page 7-4).

Power Management This option controls a hardware-based power management setting on the Spectrum24 radio card. It is not related to the software-based PPT 4300 Power Management scheme, which is configured in the Power tab. This Power Management setting controls the PowerMgmt=x in either net.cfg (Novell TCP/IP stack) or protocol.ini (Microsoft TCP/IP stack). In net.cfg the value is either “Y” or “N”. In protocol.ini the value is either “1” (on) or “0” (off). Use of this Power Management scheme is not recommended with the Microsoft TCP/IP stack. When Power Management is off, the radio card draws normal power and actively maintains its radio connection. When Power Management is on, the radio card only communicates with the Access Point when it has something to send. This reduces the drain on the battery and saves power. However there can be a small but noticeable delay when the terminal needs to communicate over the network with an Access Point and host.

6-23

Page 142

PPT 4300 Series Product Reference Guide

6-24