The text of a manual · part 16 of 37
PPT 4300 Series Product Reference Guide: Chapter 6 The Control Panel, pages 127 to 134
Pages 127 to 134 of 326, from PPT 4300 Series Product Reference Guide
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PPT-4340
Page 127
The Control Panel
Options Invert Video in Text Mode: You can switch this option on or off to ensure that DOS character-based applications appear with the correct colors or to improve visibility. When this option is selected, the color palette is inverted. This means that when the video is in a text mode, specified colors are reverse polarity. For example, with the standard color map, this means that: !
black becomes white
!
white becomes black
!
dark blue becomes yellow
!
yellow becomes dark blue
!
dark green becomes pink
!
pink becomes dark green
!
dark cyan becomes light red
!
light red becomes dark cyan
!
light gray becomes dark gray
!
dark gray becomes light gray
Note that if the color palette is manipulated (which happens rarely in text video mode) the colors could be different.
6-9
Page 128
PPT 4300 Series Product Reference Guide
Keyboard Options The Keyboard tab allows you to set defaults for the behavior of keys on the keyboard. To make changes, follow the instructions in Navigating the Control Panel on page 6-4. No password is required to make changes on this page.
Figure 6-3. Control Panel Keyboard Tab
Character Repeat Repeat Delay To set the length of time that a key must be held down before it starts to repeat, adjust the position of the slider bar for Repeat Delay. The label below the slider bar changes to reflect the current time delay. The length of delay ranges from 1000 milliseconds to 250 milliseconds (adjusted in 250 millisecond increments).
Repeat Rate: To set how many characters repeat per second, adjust the position of the slider bar for Repeat Rate. The label below the slider bar changes to show the current setting. The number of characters that repeat range from 2 characters per second, to 30 characters per second. 6-10
Page 129
The Control Panel
Test Field To test any changes before you implement them, select the test field and hold down a key on the keypad.
Key Click Select this checkbox to turn the audible Key Click feature on and off. When the box is marked, the keys on the keypad click when users press them. When the box is unmarked, the keys on the keypad do not click when pressed. This is different from suppressing beeps from the host (see Quiet Mode on page 6-18).
Quick Numeric Keypad Overlay Mode The terminal’s keypad incorporates a numeric keypad, using the blue symbols marked in small letters on the 7, 8, 9, 0, U, I, O, P, J, K, L, M, > and ? keys (on the North American keypad). International keypads may vary slightly. By default, Quick Numeric Keypad Overlay Mode is off, and the numeric keypad works like this: 1. Turn NumLock on by pressing the <NumLock> key (the LED above it lights up). 2. Enter numbers by pressing the <Fn> key plus a numeric keypad key (e.g., <Fn-J> = 1). If you turn Quick Numeric Keypad Overlay Mode on (checkbox is marked on the Keyboard tab), the numeric keypad automatically works as a numeric keypad when the <NumLock> key is active (e.g., J = 1). Numeric keypad
Fn key
Figure 6-4. Numeric Keypad (North American version) 6-11
Page 130
PPT 4300 Series Product Reference Guide
Power Options The Power tab allows you to set Power Management defaults that will extend the usage time of a battery pack. The settings determine how much time an inactive terminal spends in a particular mode before switching to the next Power Management mode. You may also use this tab to turn the Power Management features off. For a complete description of the Power Management modes, see page 5-19. To make changes to the Power options, follow the instructions in Navigating the Control Panel on page 6-4. The options on this page require a password, if one exists.
Figure 6-5. Control Panel Power Tab
Stop CPU Clocks During Power Management This option controls the activity of the CPU when the terminal is in Doze or Sleep mode. If this option is selected, the CPU halts during Doze and Sleep modes and provides the most efficient Power Management. If you deselect this option, the CPU slows down when the terminal is in Doze or Sleep mode, to minimize power usage, but it still processes all system functions including radio traffic and
6-12
Page 131
The Control Panel screen updates. This ensures continual CPU availability to Citrix and other applications that need it, while still providing some Power Management.
Normal to Doze Mode If the Enable Transition checkbox is marked, the terminal enters Doze mode after it has been inactive for a certain period of time. To set the amount of time that must pass for the terminal to enter Doze mode from Normal, adjust the position of the slider on the slider bar. The range is from 17 seconds to 76 seconds. The current setting appears just below the slider bar. If the Enable Transition checkbox is not marked, the terminal will not enter Doze mode. You can enable the Normal–Doze transition without enabling transitions to Sleep or Off modes.
Doze to Sleep Mode If the Enable Transition checkbox is marked, the terminal goes into Sleep mode after it has been inactive for a certain period of time in Doze mode. To set how much time must pass in Doze mode before the terminal enters Sleep mode, re-position the slider on the slider bar. The range is 4 to 1020 seconds (17 minutes). The current setting appears just below the slider bar. If the Enable Transition checkbox is not marked, Power Management will not cause the terminal to enter Sleep mode, but you can still force the terminal into Sleep mode by pressing <Fn-F4>. The Normal–Doze transition must be enabled for the Doze–Sleep transition to be possible. If the Maintain power to PC Card sockets during sleep Mode checkbox is marked (in some versions 5V on During Sleep mode), the terminal maintains power to the PC Card slots while it is in Sleep mode. If there is no power to the PC Card slots, then the radio card will temporarily not function, and, depending on how your network is set up, the host may disconnect your session when the terminal is in Sleep mode.
Sleep to Off If the Enable Transition checkbox is marked, the terminal powers itself off after it has been inactive for a certain period of time in Sleep mode. To set the amount of time that must pass in Sleep mode for the terminal to power itself off, adjust the position of the slider on the slider bar. The range is from 1 minute to 272 minutes (4 hours, 32 minutes). The current setting appears just below the slider bar. If the Enable Transition checkbox is not marked, the terminal will not turn off until the battery runs down. The Normal–Doze and Doze–Sleep transitions must be enabled for the Sleep–Off transition to be possible. Note: A terminal is inactive when there is no keyboard or pen activity. Network activity is not considered “activity” by Power Management.
6-13
Page 132
PPT 4300 Series Product Reference Guide
Power Icon Setup (Control Panel Versions 1.77 or later) This section allows you to set the action of the Power icon during an active session. If the Sleep option is selected, the terminal enters Sleep mode when a user presses the Power icon. If the Off option is selected, the terminal powers off when a user presses the Power icon. If the Prompt user before action checkbox is selected, when the user presses the Power icon a pop-up window appears and prompts the user to confirm the Sleep or Off action. If the user presses <Enter>, the default action is selected. By default, the Power icon powers the terminal off, with a confirmation prompt. However there are also some options that can be set in the ppt4300.ini file (see Settings in ppt4300.ini on page 7-4). During a Terminal Emulation session, if you press the Power icon, the emulators ask “Close the Session (y/n)”. If you answer yes, the telnet connection will be closed. Then if FastExit is on and this was the last active session, the Terminal Emulators exit. If the “off.com” command is in the autoexec.bat the terminal powers off. In this case, you cannot use the Power icon to put the terminal into Sleep mode. Instead you can use <Fn-F4> to put the terminal into Sleep mode. See the [Emulators] section of the table on page 7-5 for more information on the FastExit option. See The Power Icon on page 5-11 for more information on the Power icon.
6-14
Page 133
The Control Panel
Battery Options The Battery tab displays current battery information and allows you to set defaults for warning messages. For a complete description of batteries and how to change a battery, see Batteries and Power on page 5-14. To make changes on this tab, follow the instructions in Navigating the Control Panel on page 6-4. The options on this page require a password, if one exists.
Figure 6-6. Control Panel Battery Tab
Battery Warning Configuration The Low Warning Window appears when battery capacity has dropped to a level where the battery pack should be changed. The Critical Warning Window appears if battery capacity drops to a level where the battery pack must be changed. Both warning windows can be disabled in ppt4300.ini. See Settings in ppt4300.ini on page 7-4 for more information. In Figure 6-6, the Low warning window is set to appear when battery capacity drops to 8%. The Critical warning window is set to appear when battery capacity drops to 4%. At 8% of battery capacity, you have about 19 minutes of normal, active use left. At 4%, you have less
6-15
Page 134
PPT 4300 Series Product Reference Guide than 10 minutes of normal use left before the terminal shuts off. To change the timing of the Battery warning messages, edit the battery capacity fields in the Battery Warning Configuration box.
Window Removal Time-out/Window Reappear Timeout A Low or Critical warning window appears on the terminal’s screen for a set period of time (e.g., 8 seconds). If you do not acknowledge the window while it is on the screen, it disappears, and then reappears a number of seconds later. The Window Removal Timeout field sets the length of time that the message window stays on the screen. The default time is 8 seconds. To change this time, adjust the position of the slider on the slider bar. The Window Reappear Timeout field sets the length of time that passes before the message window reappears, if you have not acknowledged it. The default time is 15 seconds. To change this time, adjust the position of the slider on the slider bar. To acknowledge a message, press the Close button with the pen, or press <Enter> while the message is displayed.
Remaining Battery Life This bar graph shows how much capacity the battery has left. Current battery level is marked by a line and is updated every 10 seconds. The bottom two segments of the bar appear in yellow and red. The yellow area corresponds to a battery level that will cause a Low warning window to appear. The red area corresponds to a battery level that will cause a Critical warning window to appear. If you are using an external power source (DC Adapter), the Remaining Battery Life bar freezes at the last known battery level.
Current Battery Information When the terminal is powered from a battery, the Current Battery Information area at the bottom of the screen shows battery information. !
Serial Number: The battery’s serial number.
!
Recharge Count: This feature is reserved for future use.
!
Service Date: The date the battery was initialized during manufacture.
!
Nominal Capacity: The capacity of the battery when it was first manufactured, in milliamp-hours (mAH) .
!
Last Full Charge Capacity: This option is reserved for future use.
!
Current Capacity: Shows how much capacity is left in the battery, this is the number illustrated on the Remaining Battery Life graph.
6-16