Page 143
Chapter 7 The Terminal Emulators Chapter Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Starting and Ending a Terminal Emulation Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Terminal Emulation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 Settings in ppt4300.ini . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 Double-Click Setting for Terminal Emulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Terminal Emulation Options Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 Key Click . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 Host Beeps (Quiet Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 Host Choice List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 Bypassing the Host Choice List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15 Creating the Host Choice List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15 Multiple Sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 Activating Multiple Sessions with the Pen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 Activating Multiple Sessions Using the Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21 Mainframe Session Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23
7-1
Page 144
PPT 4300 Series Product Reference Guide
7-2
Page 145
The Terminal Emulators
Overview The standard configuration for terminal emulation allows a terminal to communicate with one or more hosts. A PPT 4300 series terminal includes software for running three different terminal emulations through Telnet: 3270, 5250 and VT220. If the terminal will be used for terminal emulation, it must also have a radio card installed (e.g., the PPT 4340 model) and must be configured for network communication as described in Chapter 4, Standard Terminal Configuration. This chapter describes some terminal emulation features, including the Terminal Emulation Options screen, the Host Choice List, and Multiple Sessions. You may also define a custom key map (see Appendix B, Key Mapping for Terminal Emulators). These features are specific to terminal emulation; they do not apply to Citrix ICA Client for DOS applications, or to any DOS applications. Note: Terminal Emulation set-up and configuration is unique to the PPT 4340 and may be different from Terminal Emulation set-up and configuration for other Symbol terminals.
Starting and Ending a Terminal Emulation Session If the terminal has been set to run terminal emulations, and a Host Choice List has been set up, you can start and end sessions as described here:
Starting a session When you power up the terminal a Host Choice List appears after the terminal finishes booting. Use the pen, arrow keys, or keyboard to select a host. Then use site-specific procedures to log in (e.g., User ID and password). You may also configure the terminal to skip the Host Choice List and connect automatically to the first host on the list. See Bypassing the Host Choice List on page 7-15.
Ending a session To end a session you can: !
!
!
use site-specific procedures to end your session (e.g., type logout or press <Ctrl-D>). You can also press <Shift-Alt-X> to force the telnet session to close. When the Host Choice List reappears, select another host, or press <Esc> to power the terminal off. configure the terminal to power off when you exit your last session. See Bypassing the Host Choice List on page 7-15. define a custom key to close a telnet session. See Appendix B, Key Mapping for Terminal Emulators. 7-3
Page 146
PPT 4300 Series Product Reference Guide
Programming for the Power icon If your facility is developing Terminal Emulator applications for use with a PPT 4340, the Power icon can be configured to perform a function defined by the application. If a callback function is registered by an application, then the application determines what the Power icon does. For example, the PPT 4340 Terminal Emulators configure the Power icon to perform a ‘close current session’ function and then power off, when pressed. For more information, contact Symbol Technical Support.
Terminal Emulation Options Settings in ppt4300.ini The ppt4300.ini file determines some important settings for the terminal emulators and system utilities. Many of these settings can be changed from the Control Panel, or overridden at the Terminal Emulation Options screen described on page 7-9. However this file may also be edited manually. Table 7-1. Settings in ppt4300.ini Section
Default Setting
Description
[VT220]
Newline=1 AutoWrap=0 BackSpaceKey=1
These are VT220 defaults. You can override these in keymap.cfg, or at the Terminal Emulation Options screen (press <Shift-Alt-O> during a Terminal Emulation session).
[3270]
HostCursorHome=1
The HostCursorHome setting is a 3270 default. It controls the cursor location when you move to a new screen. When the feature is active (a value of 1), the cursor moves to any position the host requests, including the home position in the top left corner. If you deactivate this feature (a value of 0), the cursor stays in the same relative position on the new screen or moves to a field defined by the host application. However, it will not return to the home position.
Extended=1
The Extended setting controls extended 3270 commands, with host-defined colors and highlighting. A value of 1 means that support for the extended 3270 commands are on. A value of 0 means that the extended commands are off.
7-4
Page 147
The Terminal Emulators
Table 7-1. Settings in ppt4300.ini Section
Default Setting
Description
UseUserClr=0
Set UseUserClr to 1 if you want to override host defined colors with the colors defined above.
InputNormalClr= InputIntenseClr= ProtNormalClr= ProtIntenseClr=
These settings define field colors based on field attribute characteristics: Input/Protected, Normal/ Intense (or Non-Selectable/Selectable). If you list two colors for a setting, the first defines the field color for that field type when it is unmodified, and the second defines the field color when the field has been modified. If the color is to remain the same regardless of the Unmodified/Modified state, then list one color. Color commands from the host are ignored if UseUserClr is set to 1. The defaults (when no color is specified) are: InputNormalClr=Green,Green InputIntenseClr=Red,Red ProtNormalClr=Turquoise,Turquoise ProtIntenseClr=White,White The colors to choose from are: • Black • Blue • Green • Turquoise • Red • Pink • DarkGray • LightBlue • LightGreen • LightTurquoise • LightRed • LightPink • Yellow (brownish) • LightYellow • White • Neutral (dull white)
[5250]
Terminal Type=1
Use this option to set the type of 5250 terminal reported to the host by the PPT 4300. The default value is 1. Possible values include: 0 - for IBM 5251-11 (24x80 monochrome) 1 - for IBM 3179-2 (24x80 color)
[Emulators]
FastStart=0
FastStart, when set to 1, causes the terminal to skip the Host Choice List and connect to the first host on the list. The default, 0, makes the terminal boot to the Host Choice List.
[3270] (cont’d)
7-5
Page 148
PPT 4300 Series Product Reference Guide
Table 7-1. Settings in ppt4300.ini Section [Emulators] (cont’d)
Default Setting
Description
FastExit=0
FastExit, when set to 1, makes the terminal automatically exit the emulators when the last active session closes. The default, 0, makes the terminal return to the Host Choice List when the last active session closes.
DiamondsActive=1
DiamondsActive controls the session-switching diamonds on a Terminal Emulator’s status line . The diamonds can be used to switch sessions with the pen. The default is 1. To prevent the diamonds from appearing, set DiamondsActive to 0.
DrawPointerArrow=0 DrawPointerArrow controls the presence of a visible arrow pointer for the pen on the screen when the emulators are running. A value of 0 (the default) means the arrow pointer is not visible. A value of 1 means the arrow is visible.
[Pen]
7-6
RightEqualsLeft=0
RightEqualsLeft controls the action of a right pen tap in a terminal emulation session. When set to 0 (the default), a left pen tap moves the cursor and performs the Pen Select action, and a right pen tap simply moves the cursor. When set to 1, then a right pen tap performs the same function as the left pen tap.
DoubleClick=0
DoubleClick defines the double click speed for the double click heuristic in the digitizer driver and can have a value from 0 (slowest) to 9 (fastest). You can also set this at the Control Panel. For the Terminal Emulators (which do not use the double-click), set this value to 9 to improve pen tap response.
LeftClick=1
Set LeftClick to 1 (the default) to have the default pen tap act as a left mouse button click. When set to 0, the default pen tap becomes a right mouse button click. You can also set this at the Control Panel.
Page 149
The Terminal Emulators
Table 7-1. Settings in ppt4300.ini Section [Battery]
Default Setting
Description
RemoveTimer=8
RemoveTimer determines how long a battery warning message appears before being removed (must be <10 seconds). You can also set this at the Control Panel.
WarningAlert=8
WarningAlert determines the battery percentage at which the Battery Low Warning appears. You can also set this at the Control Panel.
CriticalAlert=4
CriticalAlert determines the battery percentage at which the Battery Critical Warning appears. You can also set this at the Control Panel.
ReappearTimer=15
ReappearTimer determines how many seconds will pass before a battery message reappears, if not acknowledged (15 - 60 seconds). You can also set this at the Control Panel.
WantAlerts=1
WantAlerts controls whether the low battery alert windows will pop up when the battery runs low. It defaults to 1 (on). If set to 0, the battery alerts will not display when the battery runs low. However the Low Battery LED still functions. This feature can only be set in ppt4300.ini.
[Power PowerIconOff=1 Management]
PowerIconPrompt=0
This setting controls the Power icon. A 1 means the terminal will turn off when the Power icon is pressed (default). A 0 means the terminal will enter Sleep mode. This setting controls a user confirmation prompt for the Power icon. A 1 means that a confirmation prompt appears when a user presses the Power icon, and the user must select “Sleep” or “Off”. A 0 means the terminal powers off or goes into Sleep mode with no confirmation prompt when the user presses the Power icon. You can change these settings at the Power tab of the Control Panel. See Power Options on page 6-12.
7-7
Page 150
PPT 4300 Series Product Reference Guide
Table 7-1. Settings in ppt4300.ini Section [System]
Default Setting
Description
SerialNumber=
This contains the terminal's serial number (it may be blank). Do not change the serial number.
WantPopups=1
WantPopups controls whether the Battery Status, Settings and Low RSSI windows will pop up when the appropriate Direct Access icons or Fn-keys are pressed. The default is 1. If set to 0, then the Battery Status and Settings pop-up windows will not appear. It does not control the user confirmation window that may appear when a user presses the Power Icon. Use PowerIconPrompt for this.
PermitS24Info=0
If the terminal uses a Spectrum24 card, PermitS24Info determines whether on-screen Spectrum24 information will be available to the user when using the RF/AP utility to test RF signal strength. If set to 1, the on-screen Spectrum24 information is allowed. The default is 0 (disabled).
S24InfoWantAP=0
S24InfoWantAP controls whether the on-screen S24 information will include the Access Point ID of the associated Access Point. The default is 0 (disabled).
S24LowRSSILevel=0
This sets the threshold for the Poor Reception/Low RSSI warning. This pop-up window provides an immediate warning if a user enters an area with poor radio reception. The RSSI range is 0 to 99. Default value for this setting is 0 (disabled). It can be set at the Control Panel.
Double-Click Setting for Terminal Emulators Since Terminal Emulators do not use double-clicking, you can disable the Double-Click by setting the Double-Click Speed to Fast on the Display tab of the Control Panel. This improves Terminal Emulation pen reliability. It is a recommended Control Panel setting for use with Terminal Emulators.
7-8