Page 33

Chapter 3 Spectrum24 RF Terminal Setup Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Spectrum One Vs. Spectrum24 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 The Flash Disk Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Standard Spectrum24 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Decision: Internet Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Editing NET.CFG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 How Application Files Are Downloaded to the Terminal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Loading the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Hardware Required for Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Hardware Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Verify Existence of Application Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Download Over the Network: BOOTP (Default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Initiate Network Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Terminal Attempts to Associate with Access Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Download Over the Network: DHCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 Download Over the Network: Neither BOOTP or DHCP. . . . . . . . . . . . . . . . . . . . . . . . . . 3-13

3-1

Page 34

Series 3100 / 3500 Product Reference Guide

3-2

Page 35

Introduction to Spectrum24 RF Terminals

Introduction Spectrum One Vs. Spectrum24 Terminals In Spectrum One terminals, connectivity over the wireless network is effected through a proprietary protocol. A terminal was dedicated to a specific application using a hex image customized for the application (e.g., STEP or SVTP) that was loaded offline into the terminal’s non-volatile memory (NVM). Any temporary files needed or created by the application were placed on the RAM drive which used part of the program execution space. The NVM appears to the application as a read-only disk drive (B:) containing up to 256 Kbytes. The RAM drive (D:) is both readable and writable and is sized by each application according to the application’s needs. In Spectrum24 terminals, the wireless connectivity is accomplished using standard communications protocols. Because they are standard, the protocols are generalized and take up considerably more space on the terminal’s NVM. With less space available in NVM for application files, Spectum24 terminals operate as diskless computing workstations. The terminal’s NVM contains system files required to connect to and download the application files from a network server and to provide network diagnostics and configuration. The application files are downloaded each time the terminal is booted.

The Flash Disk Option The 3140 and 3540 terminals optionally can contain an additional megabyte of nonvolatile memory or flash disk. This extra memory is used to reduce the time and resources required to load applications into the terminal and to offer the possibility of running multiple applications from the same terminal. The flash disk is accessed via a driver, FLASHDSK.SYS, which makes the flash disk appear to a program as another disk drive (E:). The drive has characteristics of fast reading but slow writing (e.g., for even the smallest files, the write process takes 3-4 seconds). If your 3140/3540 terminal includes a flash disk, you have options for setting the IP address and downloading software that are not available on the standard Spectrum24 terminals. For more information, refer to the Spectrum24 Flash Disk Addendum.

3-3

Page 36

Series 3100 / 3500 Product Reference Guide

Standard Spectrum24 Installation A standard Spectrum24 installation consists of LSL, SLAODI.COM, TCP/IP, and NET.CFG, and requires a BIOS version of 1.09 or later. The system software is factory-loaded in the terminals. The default files cover most expected scenarios with minor changes, as detailed in this chapter. If your requirements are more sophisticated, refer to the Spectrum24 Network Development Kit documentation for more information on the Spectrum24 RF network, SLAODI.COM, the Symbol-provided ODI driver, and the configuration file setups required for various platforms. Note:

The installation for Spectrum24 terminals with flash disk differs from a standard installation in the configuration file setup and in the options for obtaining addresses and downloading software. For more information, refer to the Spectrum24 Flash Disk Addendum.

Decision: Internet Addressing Each terminal requires a unique internet address, or IP address, allowing messages it sends and receives to be correctly routed over networks conforming to the TCP/IP protocol standards. These addresses can be administered and entered manually, or administered and allocated by a server on the network. Two protocols are defined for the IP address allocation on the network, BOOTP and DHCP. BOOTP is commonly used in UNIX and OS/2; DHCP is the protocol for Windows NT servers. By default, Symbol’s Series 3000 Spectrum24 terminals use the BOOTP protocol to obtain an IP address. To allocate IP addresses manually or to use the DHCP protocol, you must change the “boot” parameter in the [Spectrum24 Control] section of the NET.CFG file that is loaded on the terminal. The format of the entries to NET.CFG is discussed in the section Editing NET.CFG.

Editing NET.CFG The terminal is controlled by entries in the NET.CFG file. After you decide how to allocate IP addresses, edit NET.CFG to include the [Spectrum24 Control] section necessary to set the IP addressing mode. If you intend to make any changes to the terminal’s out-of-box default setup, you must add the [Spectrum24 Control] section, which specifies parameters that apply to all Spectrum24 uses, to NET.CFG.

3-4

Page 37

Introduction to Spectrum24 RF Terminals

[Spectrum24 Control] This section includes the parameters for indicating the preferred method of obtaining the IP address (over the air or manual), as defined in Table 3-1, Parameters in [Spectrum24 Control] Section. Table 3-1. Parameters in [Spectrum24 Control] Section Parameter

Description bootp

By default, the terminal issues a BOOTP request on startup. If no Spectrum24 Control Section appears in NET.CFG, BOOTP is assumed.

noboot

If this parameter is set to noboot, the terminal does not issue a BOOTP request. The terminal IP address must be entered in the [TCPIP] section of NET.CFG or manually using CFG24.

dhcp

For a Windows NT environment, the terminal uses DHCP protocol to access the network.

Note: The DHCP, BOOT, and NOBOOT modes are mutually exclusive.

Examples Entries to a NET.CFG setup: Spectrum24 control DHCP

OR Spectrum24 control Noboot

If you change NET.CFG, the default HEX image must be rebuilt.

3-5

Page 38

Series 3100 / 3500 Product Reference Guide

How Application Files Are Downloaded to the Terminal To download application files requires having a Trivial File Transfer Protocol (TFTP) server on the network. If your site has more than 3-4 terminals, running a TFTP server on a DOS-based machine is impractical because the operating system restricts you to downloading to one terminal at a time. More sophisticated operating systems, e.g., UNIX, OS/2, or Windows NT, allow downloads to multiple terminals simultaneously. The server is needed infrequently to load new applications or update existing applications. Downloading over the airwaves cannot be done until after the Internet addressing decision is resolved, and any required edits to NET.CFG are entered because the IP address is required to perform the file transfer.

3-6

Page 39

Introduction to Spectrum24 RF Terminals

Loading the Software Hardware Required for Download • Terminal • Spectrum24 RF Network Boot Server • Spectrum24 Ethernet Access Point Note:

No hardware connections (cradle or CCA) are required to load the software over the Spectrum24 network. The terminal must be within the coverage area of a Spectrum24 Ethernet Access Point linked to a host computer. The initialization software is factory installed.

Hardware Setup Refer to the Spectrum24 RF Network documentation listed in Related Publications in About This Manual for information on the Spectrum24 network and equipment.

Verify Existence of Application Files The application files to be downloaded to the terminal must be installed on a network host before you initiate the network connection. For more information on setting up the files on a host, refer to the Spectrum24 documentation listed in About This Manual.

3-7

Page 40

Series 3100 / 3500 Product Reference Guide

Download Over the Network: BOOTP (Default) Initiate Network Connection 1.

Cold boot the terminal. Note:

Verify that terminal is OFF before cold booting.

a. Press and hold <A+B+D>. b. Press and release <PWR>. c. Release <A+B+D>. The terminal boots DR-DOS and loads the radio driver while displaying a series of boot messages. 2.

Enter a new Net Id, obtained from the Network Administrator, in the Configurator (DFG24). Note:

This process should only be required on the first-time, out-of-box network connection.

On first boot , the terminal automatically brings up the Configurator screen for entering a new Net Id: CONFIGURATOR 1.XX View config params Net Id Subnet Mask Default Router Terminal IP Address Exit ↑ , Clear, Enter ↑

3.

To enter the new Net Id: a. Use the <UpArrow> and <DownArrow> to cursor to Net Id. b. The default Net Id appears in hex format. Backspace over the existing value, type a new value in the range 102-1FE (in hex, not case sensitive), and press <ENTER>. c. If you are using a BOOTP or DHCP server, cold boot the terminal and proceed to the section, Terminal Attempts to Associate with Access Point.

4.

If you are not using a BOOTP or DHCP server, enter the following parameters: - Subnet Mask

3-8

Page 41

Introduction to Spectrum24 RF Terminals

- Default Router - Terminal IP Address and press <ENTER> after each entry. Note:

5.

Your changes are saved in the nonvolatile area on the radio card. The values just entered are not lost if you reboot the terminal.

Select Exit from the Configurator Menu and press <ENTER> to exit the Configurator to continue the connection process.

Terminal Attempts to Associate with Access Point The terminal attempts to associate with an Access Point (AP) using the default Net Id.

If Terminal Association with AP Is Not Successful If the terminal is unable to associate with the AP (the Net Id is wrong or forgotten), it displays the message: STAT24 Ver 1.XX NOT Associated for a few seconds. A second message follows: Terminal cannot associate with AP. You’re out of range or not configured. Ctrl+C to end or other key to retry. Strike any key when ready.....

The terminal continues trying to connect until attempt is cancelled. To cancel and set up a new Net Id (obtained from the Network Administrator): 1.

Press <Ctrl+C> to end the attempt. The terminal displays the message: Halt Batch process Y/N?

2.

Type Y to exit to the DOS prompt (D:).

3.

At the DOS prompt, type CFG24 and press <ENTER> to initiate the Configurator and bring up the Configurator screen: CONFIGURATOR 1.XX View config params Net Id Subnet Mask Default Router

3-9

Page 42

Series 3100 / 3500 Product Reference Guide

Terminal IP Address Exit ↑ , Clear, Enter ↑

4.

Use the <UpArrow> and <DownArrow> to cursor to Net Id.

5.

The current Net Id appears in hex format. Backspace over the existing value, type a new value in the range 102-1FE (in hex, not case sensitive), and press <ENTER>.

6.

Power the terminal off.

7.

Cold boot again.

8.

The terminal attempts to associate with an AP.

If Terminal Association with AP Is Successful If the association is successful, the terminal obtains an IP address and bootfile name, displays the message: BOOTP 1.XX and begins downloading files from the server. As the download runs, the terminal displays a series of application-defined messages. If the download is successful, the terminal displays messages indicating success and the application logon screen. Begin operating the terminal application. Note:

For flash disk terminals, if the terminal is not downloading files over the air, the files are extracted from flash disk and executed.

If Association Is Successful But Download Fails The download may fail due to one of the following reasons: Terminal Cannot Find BOOTP Server. If the terminal cannot find the BOOTP or DHCP Server for download, it displays the message: Cannot find Boot Server, time out You have no boot server or it has problems and returns to the DOS prompt. Contact the Symbol Support Center for assistance. File Transfer Fails. If the file transfer fails, the terminal displays the message:

3-10

Page 43

Introduction to Spectrum24 RF Terminals

TFTP retry counter exceeded, Receive timeout. Error <filename> Ctrl-C to end or other key to retry.

where <filename> is the file being transferred that was not fully downloaded. The terminal may be out of range of the AP and cannot find the files to transfer. 1.

Press <Ctrl+C> to exit and request help from the Symbol Support Center. OR

2.

Press a key to retry the file transfer.

If File Transfer Succeeds If the file transfer retry is successful, the terminal displays messages indicating success and the application logon screen. Begin operating the terminal application. If not, contact the Symbol Support Center for assistance.

3-11

Page 44

Series 3100 / 3500 Product Reference Guide

Download Over the Network: DHCP To use the DHCP protocol requires editing NET.CFG and rebuilding the HEX file before initiating the network connection. 1.

Edit NET.CFG (refer to the section Editing NET.CFG for a more detailed discussion). Add the section header and DHCP parameter line: Spectrum24 Control DHCP

2.

Save the new NET.CFG on the network host in the \LWPnnn\KIT directory.

3.

Working from the \LWPnnn\KIT directory, rebuild the HEX file. Use the command: USRCFG @LWPNFL which builds a LWPNFL.HEX file in the KIT subdirectory. 4.

Download the new HEX file. Refer to the Series 3000 ADK for instructions on downloading a HEX file to the terminal.

5.

Proceed with the network connection as described in the section Initiate Network Connection.

3-12

Page 45

Introduction to Spectrum24 RF Terminals

Download Over the Network: Neither BOOTP or DHCP If a BOOTP or DHCP server is not used, the information these servers provide must be obtained in other ways (i.e., the IP address is entered manually using CFG24). 1.

Edit NET.CFG (refer to the section Editing NET.CFG for a more detailed discussion). Add a control section and noboot parameter: Spectrum24 control Noboot

2.

Proceed with saving the NET.CFG file, building and downloading a new HEX file, and connecting to the network as described in Download Over the Network: DHCP.

3-13

Page 46

Series 3100 / 3500 Product Reference Guide

3-14