Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 18

Series 3100/3500 Product Reference Guide: Chapter 2 Batch and Spectrum One Terminal Setup

Pages 23 to 32 of 170, from Series 3100/3500 Product Reference Guide

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-3100, Symbol PDT-3110, Symbol PDT-3140, Symbol PDT-3500, Symbol PDT-3510 and Symbol PDT-3540

Page 23

Chapter 2 Batch and Spectrum One Terminal Setup Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Hardware Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Hardware Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Connect Host and Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Connect Host & 3115 CCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Loading the Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Initiate Host Communications Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Initiate Terminal Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Starting Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 Ending Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

2-1

Page 24

Series 3100 / 3500 Product Reference Guide

2-2

Page 25

Batch and Spectrum One Terminal Setup

Introduction Before using a Series 31XX/35XX terminal, perform the following procedures: • install the battery (Refer to Chapter 6) • charge the battery, if using a Nickel Cadmium (NiCd) or Nickel Metal Hydride (NiMH) rechargeable battery (Refer to Chapter 6) • Load the system files and application(s). Programs are stored in the terminal’s nonvolatile memory (NVM), also called the application EEPROM.

2-3

Page 26

Series 3100 / 3500 Product Reference Guide

Hardware Requirements The following hardware is required to initialize a batch or Spectrum One radio terminal: • Terminal • 1- or 4-Slot Cradle OR 3115 Charging and Communications Adapter • RS-232 Serial Null Modem Cable • Power Supply • Host PC

Communications For terminals being used in a direct communications (batch) environment or a Spectrum One network environment, applications are transferred from a host computer to the terminal: • over a communications line using a null modem connected to the cradle OR • through the communications/charger adapter. The procedure uses the SENDHEX command on the host computer and the Program Loader function (from Command Mode) on the terminal. Note:

For details on the SENDHEX command, refer to the Series 3000 Application Programmer's Manual.

Other software may be used in place of SENDHEX.

2-4

Page 27

Batch and Spectrum One Terminal Setup

Hardware Setup Connect Host and Cradle

Host Computer

Serial Null Modem Cable

Power Connector

Power Supply Cord

Comm Port

Figure 2-1. Cradle Setup for 3100/3110 and 3500/3510 Initialization Note:

The procedure for connecting 1- and 4-slot cradles is the same.

1.

Plug the RS-232 serial cable’s connector into the cradle’s communication port.

2.

Connect the other connector to the host computer’s serial (COMM) port.

3.

Connect the power supply cord’s round plug to the power connector on the side of the cradle (3165: power supply p/n 59915-00-00 for domestic use, 60507-00-00 for international use; 3166: power supply p/n 60153-00-00 for domestic use and 60174-00-00 for international use).

4.

Connect the power supply’s AC plug to a standard electrical outlet. The green and red indicators light for about 3 seconds, blink for 3 seconds, then go out.

5.

Place the terminal in the cradle.Verify that the terminal is OFF.

6.

Go to Loading the Program.

2-5

Page 28

Series 3100 / 3500 Product Reference Guide

Connect Host, 3115 CCA

RJ41

3115 CCA

Power Input Jack DB25

Figure 2-2. 3115 CCA Setup for 3100/3110 and 3500/3510 Initialization 1.

Verify that the terminal is OFF.

2.

Plug the 10-pin RJ-41 connector in the terminal base.

3.

Plug the DB25 connector into the host’s communications port.

4.

Go to Loading the Program.

Caution The 3115 CCA cable should be used to charge ONLY the KT12956-01 NiCd battery pack. Note:

2-6

It is not necessary to connect to a power supply for communications.

Page 29

Batch and Spectrum One Terminal Setup

Loading the Program Note:

To cancel communications at any time during the session, press CLEAR on the terminal. The session stops immediately.

To download the program, initiate the communications software on the host computer and terminal as described in the following sections. Note:

Communication parameters specified on the host and the terminal must match. These parameters typically are: 38400 bps 7 bit data Odd parity Xon/Xoff flow control

Note:

To program the EEPROM, the terminal must be connected to the host through a cradle or the 3115 CCA.

Initiate Host Communications Software 1.

Power on the host computer.

2.

Start the communication program.

3.

Enter the SENDHEX command. sendhex pgmname 38400 com2 where: SENDHEX is the command.

pgmname is the application being loaded (.hex extension is optional).

parameters

Communications parameters follow the program name. Parameters include baud rate, communications port, data bits, parity, and flow control. To accept the default parameters, do not enter a value.

In the example, the baud rate is set to 38400 bps and the communications port to COM2. The default values are accepted for the remaining parameters.

2-7

Page 30

Series 3100 / 3500 Product Reference Guide

Note:

4.

Versions of SENDHEX earlier than 3.0 do not support flow control. If you use an earlier version and encounter communication errors, use a lower baud rate.

SENDHEX displays the prompt:

Press <Enter> to begin communications. 5.

Do NOT press <ENTER> yet. Before starting communications (refer to Starting Communications), set up the terminal as directed in Initiate Terminal Communications.

Initiate Terminal Communications 1.

Boot the terminal to command mode. Refer to Chapter 4, Operating the Series 3100/ 3500, for a list of the boot-to-command mode sequences. The terminal displays the following: COMMAND MODE Select function Self test

2.

Scroll through Command Mode options using <UpArrow> or <DownArrow> until “Program loader” is displayed. Press <ENTER>.

3.

The terminal displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>

Before loading the new application, erase the NVM’s original contents. Note: 4.

To cancel this operation, press <CLEAR>.

Press <ENTER> to erase the EEPROM. Wait while the EEPROM is erased. When complete, the program prompts for the communications parameters.

2-8

Page 31

Batch and Spectrum One Terminal Setup

5.

Baud Rate.The terminal displays: Comm Parameters Baud 4 9600

Scroll through the list using <UpArrow> or <DownArrow>. When the correct rate is displayed (38400 is recommended), press <ENTER>. 6.

Data Bits. The terminal displays: Comm Parameters Data Bits 7

Press <7> (recommended) or <8> to specify data bits, or scroll through the list using <UpArrow> and <DownArrow>. Press <ENTER> when the correct value is displayed. Note: 7.

If 8 data bits is selected, the program selects “No parity” and skips the next step.

Parity. If 7 data bits is selected, the terminal displays: Comm Parameters Parity Odd

Press the first letter of a parity option (Even, Odd, None, Space, or Mark), or scroll using <UpArrow> and <DownArrow> and press <ENTER> when the correct value is displayed. 8.

Flow Control. The terminal displays: Comm Parameters Flow Control None

Press the first letter of a flow control option (None, Xon/Xoff, or RTS/CTS), or scroll using <UpArrow> or <DownArrow> and press <ENTER> when the correct value is displayed. 9.

The terminal ready to receive the program.

2-9

Page 32

Series 3100 / 3500 Product Reference Guide

Starting Communications 1.

The terminal displays: Comm Parameters Start? <ENT>

2.

Press <ENT> on the terminal.

3.

Press <ENTER> on the host computer. SENDHEX begins transmitting the program image. When communications are established, the terminal displays: Program loader Receiving: XXXX

During program loading, the display shows the program segment address being transferred (XXXX). 4.

When the transmission is complete, the terminal displays: Program loader Status 0000

A status of 0000 (all zeros) indicates a successful transfer. Other status values indicate an error. These values are provided in Appendix C. If you received an error, press <Clear> on the terminal to return to the Command Mode main menu.

Ending Communications 1.

Press <Clear> on the terminal.

2.

Power down the terminal.

3.

Detach any cables connected to the terminal.

4.

Reboot the terminal using the appropriate cold boot sequence described in Chapter 4 in the section Booting a Terminal.

2-10