Page 161
Parameter Menus
ACK/NAK with ENQ This combines the two previous options.
ACK/NAK with ENQ
XON/XOFF An XOFF, Transmit Off, character turns the scanner transmission off until the scanner receives an XON, Transmit On, character. There are two situations for XON/XOFF: •
XOFF is received before the scanner has data to send. When the scanner has data to send, it then waits for an XON character before transmission. The scanner waits up to two seconds to receive the XON. If the XON is not received within this time, the scanner issues an error indication and discards the data.
•
XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.
XON/XOFF
5-91
Page 162
P460/P360 Memory Scanners Product Reference Guide
Host Serial Response Time-out This parameter specifies how long the scanner waits for an ACK, NAK or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option. The default time is set to 2 seconds. The delay period can range from 0.0 to 9.9 seconds in 0.1 second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
HOST SERIAL RESPONSE TIME-OUT
RTS Line State Note: This only applies to the scanner in corded mode. It has no affect when uploading data through the cradle. Scan the appropriate bar code below to set the idle state of the Serial Host RTS line. Choose LOW RTS line state or HIGH RTS line state.
*HOST: LOW RTS
HOST: HIGH RTS
5-92
Page 163
Parameter Menus
Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
*1 STOP BIT
2 STOP BITS
ASCII Format This parameter allows the cradle to interface with devices requiring a 7-bit or 8-bit ASCII protocol.
7-BIT
*8-BIT
5-93
Page 164
P460/P360 Memory Scanners Product Reference Guide
Beep on <BEL> When this parameter is enabled, the scanner beeps when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to indicate an illegal entry or other important event.
BEEP ON <BEL> CHARACTER (ENABLE)
*DO NOT BEEP ON <BEL> CHARACTER (DISABLE)
Intercharacter Delay Select the intercharacter delay option matching host requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. The delay period can range from no delay to 99 ms in 1 ms increments (if you are using a cradle and RTS/CTS handshaking, the delay period can range from 5 ms to 99 ms). After scanning the bar code below, scan two bar codes beginning on page 5-99 to set the desired time-out. If you make an error, or wish to change your selection, scan CANCEL on page 5-101. The default time is set to 0.
INTERCHARACTER DELAY
5-94
Page 165
Parameter Menus
MCL-Net Parameters MCL-Net Baud Rate Baud rate is the number of bits of data transmitted per second. Scan the appropriate bar code below to set the MCL-Net baud rate. The default baud rate is 38400.
BAUD RATE 600
BAUD RATE 1200
BAUD RATE 2400
5-95
Page 166
P460/P360 Memory Scanners Product Reference Guide
BAUD RATE 4800
BAUD RATE 9600
BAUD RATE 19200
*BAUD RATE 38400
5-96
Page 167
Parameter Menus
MCL-Net Hex Addressing Mode Scan the appropriate bar code below to set the MCL-Net Hex addressing mode. The default mode is Disabled.
*MCL-NET HEX ADDRESSING DISABLED
MCL-NET HEX ADDRESSING ENABLED
5-97
Page 168
P460/P360 Memory Scanners Product Reference Guide
Scanner Address Scan the following barcode, followed by 3 digits from the numeric barcode section (starting on page 5-99), to set the address of the scanner (scanner ID). The default address is set to 001. The number of scanner addresses (scanner ID’s) varies with the selected communication protocol. •
RS-232/Synapse range from 001 to 254
•
MCL Link Lite (MCL Net)
range from 001 to 002
•
MCL Link (MCL Net)
range from 001 to 254
SCANNER ADDRESS
MCL-Net Transmit Retries Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-99), to define the number of retries in the range 1 to 10. The default is set to 3 retries.
MCL-NET RETRIES
MCL-Net Frame Timeout Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-99), to define the amount of time to wait for an ACK or NAK from the host before retransmitting. The timeout is in 100 ms increments in the range 100 ms to 3000 ms. The default time is set to 500 ms.
MCL-NET FRAME TIMEOUT
5-98
Page 169
Parameter Menus
Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
0
1
2
3
4
5-99
Page 170
P460/P360 Memory Scanners Product Reference Guide
Numeric Bar Codes (Continued)
5
6
7
8
9
5-100