The text of a manual · part 18 of 23

P460/P360 Memory Scanners Product Reference Guide: Chapter 5 Parameter Menus, pages 151 to 160

Pages 151 to 160 of 198, from P460/P360 Memory Scanners Product Reference Guide

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol P460

Page 151

Parameter Menus

UPC/EAN Security Level The Phaser offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.

UPC/EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

*UPC/EAN SECURITY LEVEL 0

UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.

UPC/EAN SECURITY LEVEL 1

UPC/EAN Security Level 2 If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.

5-81

Page 152

P460/P360 Memory Scanners Product Reference Guide

UPC/EAN SECURITY LEVEL 2

UPC/EAN Security Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised that selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.

UPC/EAN SECURITY LEVEL 3

5-82

Page 153

Parameter Menus

RS-232 Parameters Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

BAUD RATE 600

BAUD RATE 1200

BAUD RATE 2400

5-83

Page 154

P460/P360 Memory Scanners Product Reference Guide

BAUD RATE 4800

*BAUD RATE 9600

BAUD RATE 19200

BAUD RATE 38400

5-84

Page 155

Parameter Menus

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

ODD

If you select EVEN parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

EVEN

Select MARK parity and the parity bit is always 1.

MARK

5-85

Page 156

P460/P360 Memory Scanners Product Reference Guide

Select SPACE parity and the parity bit is always 0.

SPACE

If no parity is required, select NONE.

*NONE

Check Receive Errors Select whether or not the parity, framing, and overrun of received characters are checked. The type of parity used is selectable through the PARITY parameter.

CHECK FOR RECEIVED ERRORS

*DO NOT CHECK FOR RECEIVED ERRORS

5-86

Page 157

Parameter Menus

Hardware Handshaking The data interface consists of an RS-232 port. The port has been designed to operate either with or without the hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send. If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence: •

The scanner reads the CTS line for activity. If CTS is asserted, the scanner waits up to two seconds for the host to negate the CTS line. If, after two seconds (default), the CTS line is still asserted, the scanner sounds a transmit error and any scanned data is lost.

•

When the CTS line is negated, the scanner asserts the RTS line and waits up to two seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. If, after two seconds (default), the CTS line is not asserted, the scanner sounds a transmit error and discards the data.

•

When data transmission is complete, the scanner negates RTS 10 msec after sending the last character.

•

The host should respond by negating CTS. The scanner checks for a negated CTS upon the next transmission of data.

During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded. If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned. If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking will take precedence. Note: The DTR signal is jumpered active.

Note: When using RTS/CTS handshaking and a cradle, there is an 8 ms delay for the information to travel between the host and the scanner. If this setup is necessary, scan the Intercharacter Delay bar code on page 5-94 and set the delay for 10 ms or more.

5-87

Page 158

P460/P360 Memory Scanners Product Reference Guide

Scan the bar code below if no Hardware Handshaking is desired.

*NONE

Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.

STANDARD RTS/CTS

When RTS/CTS Option 1 is selected, the cradle asserts RTS before transmitting and ignores the state of CTS. The scanner deasserts RTS when the transmission is complete.

RTS/CTS OPTION 1

5-88

Page 159

Parameter Menus

When Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within two seconds (default), the scanner issues an error indication and discards the data.

RTS/CTS OPTION 2

When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to two seconds (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner deasserts RTS when transmission is complete.

RTS/CTS OPTION 3

Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence.

None When this option is selected, data is transmitted immediately.

*NONE

5-89

Page 160

P460/P360 Memory Scanners Product Reference Guide

ACK/NAK When this option is selected, after transmitting data, the cradle expects either an ACK, Acknowledge, or NAK, Negative Acknowledge, response from the host. Whenever a NAK is received, the cradle transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the cradle issues an error indication and discards the data. The cradle waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the cradle does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.

ACK/NAK

ENQ When this option is selected, the cradle waits for an ENQ, Enquiry, character from the host before transmitting data. If an ENQ is not received within two seconds, the cradle issues an error indication and discards the data. The host must transmit an ENQ character at least every two seconds to prevent transmission errors.

ENQ