Page 149

Parameter Menus

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

ODD

If you select EVEN parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

EVEN

Select MARK parity and the parity bit is always 1.

MARK

5-81

Page 150

P460/P360 Memory Scanners Product Reference Guide

Select SPACE parity and the parity bit is always 0.

SPACE

If no parity is required, select NONE.

*NONE

Check Receive Errors Select whether or not the parity, framing, and overrun of received characters are checked. The type of parity used is selectable through the PARITY parameter.

CHECK FOR RECEIVED ERRORS

*DO NOT CHECK FOR RECEIVED ERRORS

5-82

Page 151

Parameter Menus

Hardware Handshaking The data interface consists of an RS-232 port. The port has been designed to operate either with or without the hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send. If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence: !

The scanner reads the CTS line for activity. If CTS is asserted, the scanner waits up to two seconds for the host to negate the CTS line. If, after two seconds (default), the CTS line is still asserted, the scanner sounds a transmit error and any scanned data is lost.

!

When the CTS line is negated, the scanner asserts the RTS line and waits up to two seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. If, after two seconds (default), the CTS line is not asserted, the scanner sounds a transmit error and discards the data.

!

When data transmission is complete, the scanner negates RTS 10 msec after sending the last character.

!

The host should respond by negating CTS. The scanner checks for a negated CTS upon the next transmission of data.

During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded. If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned. If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking will take precedence. Note: The DTR signal is jumpered active.

Note: When using RTS/CTS handshaking and a cradle, there is an 8 ms delay for the information to travel between the host and the scanner. If this setup is necessary, scan the Intercharacter Delay bar code on page 5-90 and set the delay for 10 ms or more.

5-83

Page 152

P460/P360 Memory Scanners Product Reference Guide

Hardware Handshaking (Continued) Scan the bar code below if no Hardware Handshaking is desired.

*NONE

Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.

STANDARD RTS/CTS

When RTS/CTS Option 1 is selected, the cradle asserts RTS before transmitting and ignores the state of CTS. The scanner deasserts RTS when the transmission is complete.

RTS/CTS OPTION 1

5-84

Page 153

Parameter Menus

When Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within two seconds (default), the scanner issues an error indication and discards the data.

RTS/CTS OPTION 2

When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to two seconds (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner deasserts RTS when transmission is complete.

RTS/CTS OPTION 3

Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence.

None When this option is selected, data is transmitted immediately.

*NONE

5-85

Page 154

P460/P360 Memory Scanners Product Reference Guide

Software Handshaking (Continued) ACK/NAK When this option is selected, after transmitting data, the cradle expects either an ACK, Acknowledge, or NAK, Negative Acknowledge, response from the host. Whenever a NAK is received, the cradle transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the cradle issues an error indication and discards the data. The cradle waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the cradle does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.

ACK/NAK

ENQ When this option is selected, the cradle waits for an ENQ, Enquiry, character from the host before transmitting data. If an ENQ is not received within two seconds, the cradle issues an error indication and discards the data. The host must transmit an ENQ character at least every two seconds to prevent transmission errors.

ENQ

ACK/NAK with ENQ This combines the two previous options.

ACK/NAK with ENQ

5-86

Page 155

Parameter Menus

Software Handshaking (Continued) XON/XOFF An XOFF, Transmit Off, character turns the scanner transmission off until the scanner receives an XON, Transmit On, character. There are two situations for XON/XOFF: !

XOFF is received before the scanner has data to send. When the scanner has data to send, it then waits for an XON character before transmission. The scanner waits up to two seconds to receive the XON. If the XON is not received within this time, the scanner issues an error indication and discards the data.

!

XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.

XON/XOFF

Host Serial Response Time-out This parameter specifies how long the scanner waits for an ACK, NAK or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option. The default time is set to 2 seconds. The delay period can range from 0.0 to 9.9 seconds in 0.1 second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 5-95. If you make an error, or wish to change your selection, scan CANCEL on page 5-97.

HOST SERIAL RESPONSE TIME-OUT

5-87

Page 156

P460/P360 Memory Scanners Product Reference Guide

RTS Line State Note: This only applies to the scanner in corded mode. It has no affect when uploading data through the cradle. Scan the appropriate bar code below to set the idle state of the Serial Host RTS line. Choose LOW RTS line state or HIGH RTS line state.

*HOST: LOW RTS

HOST: HIGH RTS

5-88

Page 157

Parameter Menus

Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

*1 STOP BIT

2 STOP BITS

ASCII Format This parameter allows the cradle to interface with devices requiring a 7-bit or 8-bit ASCII protocol.

7-BIT

*8-BIT

5-89

Page 158

P460/P360 Memory Scanners Product Reference Guide

Beep on <BEL> When this parameter is enabled, the scanner beeps when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to indicate an illegal entry or other important event.

BEEP ON <BEL> CHARACTER (ENABLE)

*DO NOT BEEP ON <BEL> CHARACTER (DISABLE)

Intercharacter Delay Select the intercharacter delay option matching host requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. The delay period can range from no delay to 99 ms in 1 ms increments (if you are using a cradle and RTS/CTS handshaking, the delay period can range from 5 ms to 99 ms). After scanning the bar code below, scan two bar codes beginning on page 5-95 to set the desired time-out. If you make an error, or wish to change your selection, scan CANCEL on page 5-97. The default time is set to 0.

INTERCHARACTER DELAY

5-90