The text of a manual · part 18 of 22
P460/P360 Memory Scanners Product Reference Guide: Chapter 5 Parameter Menus, pages 139 to 148
Pages 139 to 148 of 188, from P460/P360 Memory Scanners Product Reference Guide
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P360 and Symbol P460
Page 139
Parameter Menus
MSI Plessey Check Digits These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.
*ONE MSI PLESSEY CHECK DIGIT
TWO MSI PLESSEY CHECK DIGITS
5-71
Page 140
P460/P360 Memory Scanners Product Reference Guide
Transmit MSI Plessey Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit.
TRANSMIT MSI PLESSEY CHECK DIGIT (ENABLE)
*DO NOT TRANSMIT MSI PLESSEY CHECK DIGIT (DISABLE)
5-72
Page 141
Parameter Menus
MSI Plessey Check Digit Algorithm When the two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of the two following algorithms may be selected.
MOD 10/MOD 11
*MOD 10/MOD 10
5-73
Page 142
P460/P360 Memory Scanners Product Reference Guide
Security Options Linear Code Type Security Levels The Phaser offers four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels are selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases. Select the security level appropriate for your bar code quality. Note: Does not apply to Code 128.
Linear Security Level 1 The following code types must be successfully read twice before being decoded Code Type
Length
Codabar
All
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
*LINEAR SECURITY LEVEL 1
Linear Security Level 2 All code types must be successfully read twice before being decoded.
LINEAR SECURITY LEVEL 2
5-74
Page 143
Parameter Menus
Linear Code Type Security Level (Continued) Linear Security Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Code Type
Length
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
LINEAR SECURITY LEVEL 3
Linear Security Level 4 All code types must be successfully read three times before being decoded.
LINEAR SECURITY LEVEL 4
5-75
Page 144
P460/P360 Memory Scanners Product Reference Guide
Bi-directional Redundancy This parameter is only valid when a Linear Code Type Security Level (see page 5-74) is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.
ENABLE BI-DIRECTIONAL REDUNDANCY
*DISABLE BI-DIRECTIONAL REDUNDANCY
5-76
Page 145
Parameter Menus
UPC/EAN Security Level The Phaser offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
UPC/EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
*UPC/EAN SECURITY LEVEL 0
UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.
UPC/EAN SECURITY LEVEL 1
5-77
Page 146
P460/P360 Memory Scanners Product Reference Guide
UPC/EAN Security Level (Continued) UPC/EAN Security Level 2 If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.
UPC/EAN SECURITY LEVEL 2
UPC/EAN Security Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised that selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.
UPC/EAN SECURITY LEVEL 3
5-78
Page 147
Parameter Menus
RS-232 Parameters Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.
BAUD RATE 600
BAUD RATE 1200
BAUD RATE 2400
5-79
Page 148
P460/P360 Memory Scanners Product Reference Guide
Baud Rate (Continued)
BAUD RATE 4800
*BAUD RATE 9600
BAUD RATE 19200
BAUD RATE 38400
5-80