The text of a manual · part 10 of 44
MiniScan MS XX07 Series Integration Guide: Chapter 5 MS 1207WA Specifications
Pages 61 to 70 of 406, from MiniScan MS XX07 Series Integration Guide
The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1207
Page 61
Chapter 5 MS 1207WA Specifications Overview This chapter provides the technical specifications for the MS 1207WA scanner.
5-1
Page 62
MS XX07 Series Integration Guide
MS 1207WA Electrical Interface
Figure 5-1. MiniScan Connector Table 5-1 lists the pin functions of the MS 1207WA.
Table 5-1. MS 1207WA Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD/D+
I/O
RS-232 Mode: Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner. USB Mode: D+ signal. During USB operation this signal is pulled up by a 1.5k Ohm resistor to begin USB enumeration. In this mode it is a differential bi-directional signal.
4
SYN_CLK
I/O
Synapse Mode: Synapse Clock line. Signal used as a clock by a Symbol Synapse host. Pin is shorted to RTS/SYN_DAT in USB cables to allow auto-detection of USB mode via signal loopback.
5
Ground
Power supply ground input and signal ground reference.
6
Power
5.0 VDC ± 10%
7
CTS/D-
5-2
I/O
RS-232 Mode: Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data. USB Mode: D- signal. During USB operation this signal works in conjunction with the D+ signal as a differential bi-directional signal.
Page 63
MS 1207WA Specifications
Table 5-1. MS 1207WA Electrical Interface (Continued) Pin No.
Pin Name
Type*
Function
8
RTS/SYN_DAT
I/O
RS-232 Mode: Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send. Synapse Mode: Synapse Data line. Used to transmit data to and from a Symbol Synapse host.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
O = Output
5-3
Page 64
MS XX07 Series Integration Guide
MS 1207WA Mechanical Drawings
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 5-2. MS 1207WA Mechanical Drawing
5-4
Page 65
MS 1207WA Specifications
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 5-3. MS 1207WA Mechanical Drawing
5-5
Page 66
MS XX07 Series Integration Guide
MS 1207WA Technical Specifications Table 5-2 provides the MS 1207WA technical specifications. Table 5-2. MS 1207WA Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level
5.0 VDC ± 10% 110 mA ± 30mA 40 mA ± 5 mA typical 200 mV peak-to-peak max.
Laser Power
0.48 mW ± 0.05 mW, λ = 670 nm nominal
Scan Rate
36 (± 5) scans/sec (bidirectional)
Print Contrast
Minimum 20% absolute dark/light reflectance measured at 670 nm.
Scan Angle
60° ± 2°
Scan Pattern
Single scan line
Skew Tolerance
± 65° from normal (see Figure 5-4 on page 5-8)
Pitch Angle
± 55° from normal (see Figure 5-4 on page 5-8)
Roll
± 20° from vertical (see Figure 5-4 on page 5-8)
Decode Depth of Field
See Figure 5-5 on page 5-9
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
Multiple 30” drops
Vibration
Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr per axis, over a frequency range of 5 Hz to 2000Hz.
ESD
± 20kV air discharge ± 8kV indirect discharge
Sealing
IP54
Note: Environmental and/or tolerance parameters are not cumulative.
5-6
Page 67
MS 1207WA Specifications
Table 5-2. MS 1207WA Technical Specifications @ 23°C (Continued) Item
Description
Operating Temperature
32° to 104°F (0° to 40°C)
Storage Temperature
-40° to 140°F (-40° to 60°C)
Humidity
5% to 95% non-condensing
Laser Class
CDRH Class II, IEC Class 2
Height
1.60 in. (4.06 cm)
Width
2.28 in. (5.79 cm)
Depth
2.94 in. (7.47 cm)
Weight
4.45 oz. (126 gm)
Note: Environmental and/or tolerance parameters are not cumulative.
5-7
Page 68
MS XX07 Series Integration Guide
Skew
Pitch
+ 65° from normal
+ 55° from normal
Pitch Angle
Skew Angle
20 mil Symbol
20 mil Symbo l
Scan Beam
8.0
8.0 in. ( in. (
203
203 mm
)
mm
)
Scan Beam
Roll Roll Angle
+ 20° from normal mil 20 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
8.0 in. (
203 mm
)
Scan Beam
Figure 5-4. Skew, Pitch and Roll 5-8
Page 69
MS 1207WA Specifications
MS 1207WA Decode Zone The MS 1207WA Wide Angle decodes symbols as shown in Figure 5-5. Typical values are shown. Table 5-3 on page 5-10 lists the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-11.
In. 12.4
Note: Typical performance at 73.4˚F (23˚C) on high quality symbols.
MS-1207WA cm 31.6
6
15.2
0
0
6
15.2
12.4
31.6
5 mil 1
4 7.5 mil
7.2 0.6
100% UPC
11
20 mil
15 40 mil
*
In. 0 cm 0
10 25.4 o f F i e l d
19 55 mil
5 12.7
W i d t h
24
15 38.1
20 50.8
25 63.5
Depth of Field *Minimum distance determined by symbol length and scan angle
Figure 5-5. MS 1207WA Decode Zone (Typical)
5-9
Page 70
MS XX07 Series Integration Guide
Table 5-3. MS 1207WA Decode Distances Symbol Density/ Symbol p/n / Bar Code Type/ W-N Ratio
Typical Working Ranges
Bar Code Content/ Contrast1
Near
Far
5 mil 64-17453-01 Code 39; 2.5:1
ABCDEFGH 80% MRD
1.0 in. 2.54 cm
7.5 mil 64-17452-01 Code 39; 2.5:1
ABCDEF 80% MRD
13 mil 64-05303-01 100% UPC
Guaranteed Working Ranges Near
Far
4.0 in. 10.16 cm
1.2 in. 3.05 cm
3.0 in. 7.62 cm
0.6 in. 1.52 cm
7.2 in. 18.29 cm
0.9 in. 2.29 cm
6.0 in. 15.24 cm
1234567890 80% MRD
0.6 in. 1.52 cm
11.0 in. 27.94 cm
0.9 in. 2.29 cm
9.0 in. 22.86 cm
20 mil 60-01429-01 Code 39; 2.2:1
123 80% MRD
Note 2
15.0 in. 38.10 cm
Note 2
13.0 in. 33.02 cm
40 mil 64-17457-01 Code 39; 2.2:1
AB 80% MRD
Note 2
19.0 in. 48.26 cm
Note 2
17.0 in. 43.18 cm
55 mil 64-17458-01 Code 39; 2.2:1
CD 80% MRD
Note 2
24.0 in. 60.96 cm
Note 2
22.0 in. 55.88 cm
1. Contrast measured as Mean Reflective Difference (MRD) at 670 nm. 2. Near ranges on lower densities (not specified) largely depend on the width of the bar code and the scan angle. 3. Working range specifications at ambient temperature 23 °C.
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge acuity. Consider width of decode zone at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-11 describes how to calculate the usable scan length. The scan angle is provided in Table 5-2 on page 5-6.
5-10