Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 44

MiniScan MS XX07 Series Integration Guide: Chapter 4 MS 1207FZY Specifications

Pages 51 to 60 of 406, from MiniScan MS XX07 Series Integration Guide

The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-1207

Page 51

Chapter 4 MS 1207FZY Specifications Overview This chapter provides the technical specifications for the MS 1207FZY scanner.

4-1

Page 52

MS XX07 Series Integration Guide

MS 1207FZY Electrical Interface

Figure 4-1. MiniScan Connector Table 4-1 lists the pin functions of the MiniScan MS 1207FZY interface.

Table 4-1. MS 1207FZY Electrical Interface Pin No.

Pin Name

Type*

Function

1

Trigger

I

Signals scanner to begin scanning session.

2

TXD

O

Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.

3

RXD

I

Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.

4

Not used

5

Ground

6

Power

I

5.0 VDC ± 10%

7

CTS

I

Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.

8

RTS

O

Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.

9

Beeper/ Download

I/O

During normal operation this signal functions as an external beeper drive line. This signal can sink 50 mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.

*I = Input

4-2

O = Output

Power supply ground input and signal ground reference.

Page 53

MS 1207FZY Specifications

MS 1207FZY Mechanical Drawings

Notes: Unless otherwise specified: • •

Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.

Figure 4-2. MS 1207FZY Mechanical Drawing

4-3

Page 54

MS XX07 Series Integration Guide

Notes: Unless otherwise specified: • •

Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.

Figure 4-3. MS 1207FZY Mechanical Drawing

4-4

Page 55

MS 1207FZY Specifications

MS 1207WA Technical Specifications Table 4-2 provides the MS 1207FZY technical specifications. Table 4-2. MS 1207FZY Technical Specifications @ 23°C Item

Description

Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level

5.0 VDC ±10% 160 mA ±40 mA 20 mA ±5 mA typical 200 mV peak-to-peak max.

Laser Power

1.0 mW ± 0.12 mW, λ = 650 nm nominal

Scan Rate

36 (± 5) scans/sec (bidirectional)

Print Contrast

Minimum 25% absolute dark/light reflectance measured at 650 nm.

Scan Angle

Default (Wide): 42° ± 2° Alternate (Narrow): 30° ± 2°

Scan Pattern

Single scan line

Skew Tolerance

± 50° from normal (see Figure 4-4 on page 4-7)

Pitch Angle

± 65° from normal (see Figure 4-4 on page 4-7)

Roll

± 20° from vertical (see Figure 4-4 on page 4-7)

Decode Depth of Field

See Figure 4-5 on page 4-8

Ambient Light Immunity Sunlight Artificial Light

8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)

Drop

Multiple 30” drops

Vibration

Unpowered scanner withstands a random vibration along each of the X, Y and Z axes for a period of one hour per axis, defined as follows: 20 to 80 Hz Ramp up to 0.04 G^2/Hz at the rate of 3dB/ octave. 80 to 350 Hz 0.04 G^2/Hz 350 to 2000 Hz Ramp down at the rate of 3 dB/octave.

Note: Environmental and/or tolerance parameters are not cumulative.

4-5

Page 56

MS XX07 Series Integration Guide

Table 4-2. MS 1207FZY Technical Specifications @ 23°C (Continued) Item

Description

ESD

± 20kV air discharge ± 8kV indirect discharge

Sealing

IP54

Operating Temperature

-4° to 122°F (-20° to 50°C)

Storage Temperature

-40° to 158°F (-40° to 70°C)

Humidity

5% to 95% non-condensing

Laser Class

CDRH Class II, IEC Class 2

Height

1.60 in. (4.06 cm)

Width

2.28 in. (5.79 cm)

Depth

2.94 in. (7.47 cm)

Weight

4.45 oz. (126 gm)

Note: Environmental and/or tolerance parameters are not cumulative.

4-6

Page 57

MS 1207FZY Specifications

Skew

Pitch

+ 50° from normal

+ 65° from normal

Pitch Angle

Skew Angle

20 mil Symbol

20 mil Symbo l

Scan Beam

15.0

15.0 in. ( in. (

381

381 mm mm

)

)

Scan Beam

Roll Roll Angle

+ 20° from normal mil 20 bol Sym

Note: Tolerances are reduced at extreme ends of the working range.

15.0 in. (

381 mm

)

Scan Beam

Figure 4-4. Skew, Pitch and Roll 4-7

Page 58

MS XX07 Series Integration Guide

MS 1207FZY Decode Zone The scanner has a selectable scan angle of either 30° or 42°. The 42° symbol decodes are shown in Figure 4-5. The figures shown are typical values. Table 4-3 on page 4-9 lists the typical and guaranteed distances for the 42° scan angle for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-11.

Note: Typical performance at 68˚F (20˚C) on high quality symbols.

MS-120XFZY

5 mil 3.25 3.00

13 mil

25.75

20 mil * (80% MRD) 20 mil * (25%MRD)

76.2

25

63.5

20

50.8

15

38.1

10

25.4

5

12.7

0

0

5

12.7

10

25.4

15

38.1

20

50.8

34.00

25

63.5

30

76.2

35

88.9

27.25

40 mil *

2.20

66.75

55 mil *

4.00

In. 0 cm 0

30

12.50

100% UPC

1.00 cm 88.9

7.00

7.5 mil

2.20 in 35

75.00

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

12.7

25.4

38.1

50.8

63.5

76.2

88.9

101.6

114.3

127.0

139.7

152.4

165.1

177.8

190.5

Depth of Field *Minimum distance determined by symbol length and scan angle

Figure 4-5. MS 1207FZY Typical Decode Zone (42o Scan Angle)

4-8

W i d t h o f F i e l d

Page 59

MS 1207FZY Specifications

Table 4-3. MS 1207FZY Decode Distances (42o Scan Angle) Symbol Density/ Symbol p/n / Bar Code Type/ W-N Ratio

Typical Working Ranges3

Guaranteed Working Ranges3

Bar Code Content/ Contrast1

Near

Far

Near

Far

5.0 mil 64-17453-01 Code 39; 2.5:1

ABCDEFGH 80% MRD

3.25 in. 8.26 cm

7.00 in. 17.78 cm

4.75 in. 12.07 cm

5.25 in. 13.34 cm

7.5 mil 64-17452-01 Code 39; 2.5:1

ABCDEF 80% MRD

3.00 in. 7.62 cm

12.50 in. 31.75 cm

4.75 in. 12.07 cm

9.00 in. 22.86 cm

13 mil 64-05303-01 100% UPC

012345678905 80% MRD

2.20 in. 5.59 cm

25.75 in. 65.41 cm

Note 2

19.00 in. 48.26 cm

20 mil 60-01429-01 Code 39; 2.2:1

123 80% MRD

1.00 in. 2.54 cm (Note 2)

34.00 in. 86.36 cm

Note 2

24.00 in. 60.96 cm

20 mil 60-02710-01 Code 39; 2.2:1

123 25% MRD

1.00 in. 2.54 cm (Note 2)

27.25 in. 69.22 cm

Note 2

22.00 in. 55.88 cm

40 mil 64-17457-01 Code 39; 2.2:1

AB 80% MRD

2.20 in. 5.59 cm (Note 2)

66.75 in. 169.55 cm

Note 2

49.00 in. 124.46 cm

55 mil 64-17458-01 Code 39; 2.2:1

CD 80% MRD

4.00 in. 10.16 cm (Note 2)

75.00 in. 190.50 cm

Note 2

55.00 in. 139.70 cm

Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.

4-9

Page 60

MS XX07 Series Integration Guide

Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-11 describes how to calculate the usable scan length. The scan angle is provided in Table 4-2 on page 4-5.

4-10