Page 51
Chapter 4 MS 1207FZY Specifications Overview This chapter provides the technical specifications for the MS 1207FZY scanner.
4-1
Page 52
MS XX07 Series Integration Guide
MS 1207FZY Electrical Interface
Figure 4-1. MiniScan Connector Table 4-1 lists the pin functions of the MiniScan MS 1207FZY interface.
Table 4-1. MS 1207FZY Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
4
Not used
5
Ground
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50 mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
4-2
O = Output
Power supply ground input and signal ground reference.
Page 53
MS 1207FZY Specifications
MS 1207FZY Mechanical Drawings
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 4-2. MS 1207FZY Mechanical Drawing
4-3
Page 54
MS XX07 Series Integration Guide
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 4-3. MS 1207FZY Mechanical Drawing
4-4
Page 55
MS 1207FZY Specifications
MS 1207WA Technical Specifications Table 4-2 provides the MS 1207FZY technical specifications. Table 4-2. MS 1207FZY Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level
5.0 VDC ±10% 160 mA ±40 mA 20 mA ±5 mA typical 200 mV peak-to-peak max.
Laser Power
1.0 mW ± 0.12 mW, λ = 650 nm nominal
Scan Rate
36 (± 5) scans/sec (bidirectional)
Print Contrast
Minimum 25% absolute dark/light reflectance measured at 650 nm.
Scan Angle
Default (Wide): 42° ± 2° Alternate (Narrow): 30° ± 2°
Scan Pattern
Single scan line
Skew Tolerance
± 50° from normal (see Figure 4-4 on page 4-7)
Pitch Angle
± 65° from normal (see Figure 4-4 on page 4-7)
Roll
± 20° from vertical (see Figure 4-4 on page 4-7)
Decode Depth of Field
See Figure 4-5 on page 4-8
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
Multiple 30” drops
Vibration
Unpowered scanner withstands a random vibration along each of the X, Y and Z axes for a period of one hour per axis, defined as follows: 20 to 80 Hz Ramp up to 0.04 G^2/Hz at the rate of 3dB/ octave. 80 to 350 Hz 0.04 G^2/Hz 350 to 2000 Hz Ramp down at the rate of 3 dB/octave.
Note: Environmental and/or tolerance parameters are not cumulative.
4-5
Page 56
MS XX07 Series Integration Guide
Table 4-2. MS 1207FZY Technical Specifications @ 23°C (Continued) Item
Description
ESD
± 20kV air discharge ± 8kV indirect discharge
Sealing
IP54
Operating Temperature
-4° to 122°F (-20° to 50°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
Humidity
5% to 95% non-condensing
Laser Class
CDRH Class II, IEC Class 2
Height
1.60 in. (4.06 cm)
Width
2.28 in. (5.79 cm)
Depth
2.94 in. (7.47 cm)
Weight
4.45 oz. (126 gm)
Note: Environmental and/or tolerance parameters are not cumulative.
4-6
Page 57
MS 1207FZY Specifications
Skew
Pitch
+ 50° from normal
+ 65° from normal
Pitch Angle
Skew Angle
20 mil Symbol
20 mil Symbo l
Scan Beam
15.0
15.0 in. ( in. (
381
381 mm mm
)
)
Scan Beam
Roll Roll Angle
+ 20° from normal mil 20 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
15.0 in. (
381 mm
)
Scan Beam
Figure 4-4. Skew, Pitch and Roll 4-7
Page 58
MS XX07 Series Integration Guide
MS 1207FZY Decode Zone The scanner has a selectable scan angle of either 30° or 42°. The 42° symbol decodes are shown in Figure 4-5. The figures shown are typical values. Table 4-3 on page 4-9 lists the typical and guaranteed distances for the 42° scan angle for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-11.
Note: Typical performance at 68˚F (20˚C) on high quality symbols.
MS-120XFZY
5 mil 3.25 3.00
13 mil
25.75
20 mil * (80% MRD) 20 mil * (25%MRD)
76.2
25
63.5
20
50.8
15
38.1
10
25.4
5
12.7
0
0
5
12.7
10
25.4
15
38.1
20
50.8
34.00
25
63.5
30
76.2
35
88.9
27.25
40 mil *
2.20
66.75
55 mil *
4.00
In. 0 cm 0
30
12.50
100% UPC
1.00 cm 88.9
7.00
7.5 mil
2.20 in 35
75.00
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
12.7
25.4
38.1
50.8
63.5
76.2
88.9
101.6
114.3
127.0
139.7
152.4
165.1
177.8
190.5
Depth of Field *Minimum distance determined by symbol length and scan angle
Figure 4-5. MS 1207FZY Typical Decode Zone (42o Scan Angle)
4-8
W i d t h o f F i e l d
Page 59
MS 1207FZY Specifications
Table 4-3. MS 1207FZY Decode Distances (42o Scan Angle) Symbol Density/ Symbol p/n / Bar Code Type/ W-N Ratio
Typical Working Ranges3
Guaranteed Working Ranges3
Bar Code Content/ Contrast1
Near
Far
Near
Far
5.0 mil 64-17453-01 Code 39; 2.5:1
ABCDEFGH 80% MRD
3.25 in. 8.26 cm
7.00 in. 17.78 cm
4.75 in. 12.07 cm
5.25 in. 13.34 cm
7.5 mil 64-17452-01 Code 39; 2.5:1
ABCDEF 80% MRD
3.00 in. 7.62 cm
12.50 in. 31.75 cm
4.75 in. 12.07 cm
9.00 in. 22.86 cm
13 mil 64-05303-01 100% UPC
012345678905 80% MRD
2.20 in. 5.59 cm
25.75 in. 65.41 cm
Note 2
19.00 in. 48.26 cm
20 mil 60-01429-01 Code 39; 2.2:1
123 80% MRD
1.00 in. 2.54 cm (Note 2)
34.00 in. 86.36 cm
Note 2
24.00 in. 60.96 cm
20 mil 60-02710-01 Code 39; 2.2:1
123 25% MRD
1.00 in. 2.54 cm (Note 2)
27.25 in. 69.22 cm
Note 2
22.00 in. 55.88 cm
40 mil 64-17457-01 Code 39; 2.2:1
AB 80% MRD
2.20 in. 5.59 cm (Note 2)
66.75 in. 169.55 cm
Note 2
49.00 in. 124.46 cm
55 mil 64-17458-01 Code 39; 2.2:1
CD 80% MRD
4.00 in. 10.16 cm (Note 2)
75.00 in. 190.50 cm
Note 2
55.00 in. 139.70 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.
4-9
Page 60
MS XX07 Series Integration Guide
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-11 describes how to calculate the usable scan length. The scan angle is provided in Table 4-2 on page 4-5.
4-10