Page 71

Chapter 6 MS 2207 Specifications Overview This chapter provides the technical specifications for the MS 2207 scanner.

6-1

Page 72

MS XX07 Series Integration Guide

MS 2207 Electrical Interface

Figure 6-1. MiniScan Connector Table 6-1 lists the pin functions of the MiniScan MS 2207 interface.

Table 6-1. MS 2207 Electrical Interface Pin No.

Pin Name

Type*

Function

1

Trigger

I

Signals scanner to begin scanning session.

2

TXD

O

Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.

3

RXD/D+

I/O

RS232 Mode: Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner. USB Mode: D+ signal. During USB operation this signal is pulled up by a 1.5k Ohm resistor to begin USB enumeration. In this mode it is a differential bi-directional signal.

4

SYN_CLK

I/O

Synapse Mode: Synapse Clock line. Signal used as a clock by a Symbol Synapse host. Pin is shorted to RTS/SYN_DAT in USB cables to allow autodetection of USB mode via signal loopback.

5

Ground

Power supply ground input and signal ground reference.

6

Power

5.0 VDC ± 10%

7

CTS/D-

*I = Input

6-2

O = Output

I/O

RS232 Mode: Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data. USB Mode: D- signal. During USB operation this signal works in conjunction with the D+ signal as a differential bi-directional signal.

Page 73

MS 2207 Specifications

Table 6-1. MS 2207 Electrical Interface (Continued) Pin No.

Pin Name

Type*

Function

8

RTS/SYN_DAT

I/O

RS232 Mode: Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send. USB Mode: Synapse Data line. Signal is used to transmit data to and from a Symbol Synapse host.

9

Beeper/ Download

I/O

During normal operation this signal functions as an external beeper drive line. This signal can sink 50mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.

*I = Input

O = Output

6-3

Page 74

MS XX07 Series Integration Guide

MS 2207 Mechanical Drawings

Notes: Unless otherwise specified: • •

Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.

Figure 6-2. MS 2207 Mechanical Drawing

6-4

Page 75

MS 2207 Specifications

Notes: Unless otherwise specified: • •

Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.

Figure 6-3. MS 2207 Mechanical Drawing

6-5

Page 76

MS XX07 Series Integration Guide

MS 2207 Technical Specifications Table 6-2 provides the MS 2207 technical specifications Table 6-2. MS 2207 Technical Specifications @ 23°C Item

Description

Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level

5.0 VDC ± 10% 250 ± 30 mA typical 45 ± 5 mA typical 200 mV peak-to-peak max.

Laser Power

0.95 mW ± 0.1 mW, λ = 650 nm nominal

Scan Rate

640 scans/sec.

Scan Frequency: Horizontal

320 Hz ± 5 Hz

Scan Frequency: Vertical

282 Hz ± 5 Hz

Frame Rate

24 frames/sec. 12 Hz ±1 Hz (vertical)

Print Contrast

Minimum 35% absolute dark/light reflectance differential

Scan Angle

Horizontal: 34o ±1.5o Vertical: 34o ±1.5o

Scan Pattern

Smart raster, high density single scan line

Start Time

0.065 sec. to 75% of steady state horizontal amplitude

Skew Tolerance

± 15o from plane parallel to symbol (see Figure 6-4 on page 6-8)

Pitch Angle

± 30o from normal (see Figure 6-4 on page 6-8)

Roll

± 4o from (for scanning benchmark label, assuming 3:1 codeword aspect ratio) (see Figure 6-4 on page 6-8)

Decode Depth of Field

See Figure 6-4 on page 6-8

Beam Deviation (offset from the nominal)

Horizontal: ±3.0o Vertical: ±3.0o Horizontal tilt: ± 2o

6-6

Page 77

MS 2207 Specifications

Table 6-2. MS 2207 Technical Specifications @ 23°C (Continued) Item

Description

Ambient Light Immunity Sunlight Artificial Light

8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)

Drop

Multiple 30” drops

Vibration

Unpowered scanner withstands a random vibration along each of the X, Y and Z axes for a period of one hour per axis, defined as follows: 20 to 80 Hz Ramp up to 0.04 G^2/Hz at the rate of 3dB/ octave. 80 to 350 Hz 0.04 G^2/Hz 350 to 2000 Hz Ramp down at the rate of 3 dB/octave.

ESD

± 20kV air discharge ± 8kV indirect discharge

Sealing

IP54

Operating Temperature

-4° to 122°F (-20° to 50°C)

Storage Temperature

-40° to 158°F (-40° to 70°C)

Humidity

5% to 95% non-condensing

Laser Class

CDRH Class II, IEC Class 2

Height

1.60 in. (4.06 cm)

Width

2.28 in. (5.79 cm)

Depth

2.94 in. (7.47 cm)

Weight

4.73 oz. (134 gm)

6-7

Page 78

MS XX07 Series Integration Guide

Skew

Pitch

+ 49° from normal

+ 55° from normal

Pitch Angle

Skew Angle

15 mil Symbol

15 mil Symbo l

Scan Beam

10 in

10 in

. (2

. (2

54 m

54 m m)

m)

Scan Beam

Roll + 20° from normal Roll Angle mil 15 bol Sym

Note: Tolerances are reduced at extreme ends of the working range.

10 in

. (2

54 m m)

Scan Beam

Figure 6-4. Skew, Pitch and Roll 6-8

Page 79

MS 2207 Specifications

MS 2207 Decode Zones The decode zone is a function of various symbol characteristics including density, print contrast, wide to narrow ratio and edge acurity. Typical values are shown. Table 6-3 on page 6-10 and Table 6-4 on page 6-12 list the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-11.

MS 2207 1D Decode Zone Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Vcc = 5V

In.

cm

10 25.4 7.5 15.2

MS 220X

6 mil 5.25

2.0 1.5

7.5 mil

10.1

2.5

5.1

0

0

2.5

5.1

5

10.1

7.5 15.2 10

7.0

13 mil Minimum Element Width

25.4 o f F i e l d

14.0

20 mil Minimum Element Width

19.0

40 mil Minimum Element Width

*

5

W i d t h

24.0

55 mil Minimum Element Width 31.0

In. cm

0 0

5 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

35 88.9

Depth of Field * Minimum distance determined by symbol length and scan angle.

Figure 6-5. MS 2207 1D Decode Distances 6-9

Page 80

MS XX07 Series Integration Guide

MS 2207 1D Decode Distances Table 6-3. MS 2207 1D Decode Distances Symbol Density/ Symbol p/n / Bar Code Type

Bar Code Content/ Contrast1

Typical Working Ranges3

Guaranteed Working Ranges3

Near

Far

Near

Far

6.0 mil 60-01755-01 Code 39

123 80% MRD

2.0 in. 5.08 cm

5.25 in. 13.34 cm

2.75 in. 7.00 cm

4.0 in. 10.16 cm

7.5 mil 64-17452-01 Code 39

ABCDEF 80% MRD

1.5 in. 3.81 cm

7.0 in. 17.78 cm

2.25 in. 5.72 cm

5.0 in. 12.7 cm

13 mil 64-05303-01 100% UPC

012345678905 80% MRD

Note 2

14.0 in. 35.56 cm

N/A

10.5 in. 26.67 cm

20 mil 64-17456-01 Code 39

123 80% MRD

Note 2

19.0 in. 48.26 cm

N/A

14.0 in. 35.56 cm

40 mil 64-17457-01 Code 39

AB 80% MRD

Note 2

24.0 in. 60.96 cm

N/A

18.0 in. 45.72 cm

55 mil 60-01601-01 Code 39

A 80% MRD

Note 2

31.0 in. 78.74 cm

Note 2

25.0 in. 63.50 cm

Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.

6-10

Page 81

MS 2207 Specifications

MS 2207 2D Decode Zone Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Y-module dimension = 3X. Vcc = 5V

MS 220X

2.5 6.35

W i d t h

0 o f

In.

cm

5

12.7

0

2.5 6.35 6.6 mil

6.0

1.5

5

10 mil Minimum Element Width, 35% 8.0 3.5

12.7

F i e l d

10 mil Minimum Element Width, 80% 9.0 3.5 15 mil Minimum Element Width

5.6

In. cm

0 0

2 5.1

4 10.1

6 15.2

8 20.3

10 25.4

12 30.5

15.0

14 35.6

16 40.6

Depth of Field Figure 6-6. MS 2207 2D Slab/Raster Decode Distances

Note: Not optimized for omnidirectional mode.

6-11

Page 82

MS XX07 Series Integration Guide

MS 2207 2D Decode Distances Table 6-4. MS 2207 2D Slab/Raster Decode Distances Symbol Density/ Symbol p/n / Bar Code Type

Bar Code Content/ Contrast1

Typical Working Ranges3 Near

Far

Guaranteed Working Ranges3 Near

Far

6.6 mil 64-14035-01 PDF417

ABCDEF 80% MRD

1.5 in. 3.81 cm

6.00 in. 15.24 cm

Note 2

4.75 in. 12.07 cm

10 mil 64-14937-01 PDF417

012345678905 35% MRD

3.5 in. 8.89 cm

8.0 in. 20.32 cm

Note 2

5.0 in. 12.7 cm

10 mil 64-14037-01 PDF417

80% MRD

3.5 in. 8.89 cm

9.0 in. 22.86 cm

Note 2

7.5 in. 19.05 cm

15 mil 64-14038-01 PDF417

80% MRD

5.6 in. 14.22 cm

15.0 in. 38.10 cm

Note 2

13.0 in. 33.02 cm

Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.

Note: Not optimized for omnidirectional mode.

Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge acuity. Consider width of decode zone at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-11 describes how to calculate the usable scan length.

6-12